[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934454":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},934454,604,1,"单选题","当一座设置有自动灭火系统系统的的单层三级耐火等级“山”型沥青加工厂房的占地面积大于16000平方米时，相邻两翼间的防火间距为（ ）m。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","16",false,{"key":16,"text":17,"correct":18},"B","14",true,{"key":20,"text":21,"correct":14},"C","12",{"key":23,"text":24,"correct":14},"D","10","参考《建规》3.4.7：“同一座“U”形或“山”形厂房中相邻两翼之间的防火间距，不宜小于本规范第3.4.1条的规定，但当厂房的占地面积小于本规范第3.3.1条规定的每个防火分区最大允许建筑面积时，其防火间距可为6m。”《建规》3.3.1可知，单层三级耐火等级丙类1项厂房，防火分区最大允许建筑面积为3000m2，设置自喷之后为6000m2，而题目的16000m2＞6000m2，即厂房的占地面积大于一个防火分区最大允许建筑面积，相邻两翼间的防火间距不宜小于《建规》第3.4.1条表3.4-1的规定，沥青厂房为丙类，即相当于三级丙类单层厂房与三级丙类单层厂房之间的防火间距，查表为14m，选项B正确。（也可用公式：10+（3+3-4）×2=14），故B正确。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]