[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934356":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},934356,604,2,"多选题","以下属于外墙外保温系统防火检查内容的是（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","保温材料的燃烧性能",true,{"key":16,"text":17,"correct":14},"B","电气线路与电器配件的安装",{"key":19,"text":20,"correct":14},"C","每层楼板处的防火封堵",{"key":22,"text":23,"correct":24},"D","广告牌的设置",false,{"key":26,"text":27,"correct":14},"E","防护层的设置","ABCE","建筑保温系统包括建筑内、外保温系统，主要对建筑的基层墙体或屋面板进行保置其中，建筑的屋面采用外保温系统;建筑的外墙保温方式多样，主要有内保温系统，与基层墙体、装饰层之间无空腔的建筑外墙外保温系统，与基层墙体、装饰层之间有空腔的建筑外墙外保温系统，采用保温材料与两侧墙体构成无空腔复合保温结构体的保温系统等。防火检查中，首先判定保温系统的类型，通过对保温材料的燃烧性能.防护层和防火隔离带的设置、每层楼板处的防火封堵、电气线路和电器配件的安装等进行检查，核实建筑保温系统是否符合现行国家工程建设消防技术标准的要求。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]