[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934345":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},934345,604,2,"多选题","设置在建筑物内的柴油发电机，其进入建筑物内的燃料供给管道应符合（ ）规定。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","应在进入建筑物前设置自动和手动切断阀",true,{"key":16,"text":17,"correct":14},"B","储油间的油箱应密闭且应设置通向室外的通气管，通气管应设置带阻火器的呼吸阀，油箱的下部应设置防止油品流散的设施",{"key":19,"text":20,"correct":14},"C","应在设备间内设置自动和手动切断阀",{"key":22,"text":23,"correct":24},"D","火灾危险无法靠近，可不设置手动切断阀",false,{"key":26,"text":27,"correct":24},"E","储油间的油箱应密闭且应设置通向室内通道的通气管","ABC","参考《建规》5.4.15：“设置在建筑内的锅炉、柴油发电机，其燃料供给管道应符合下列规定：1在进入建筑物前和设备间内的管道上均应设置自动和手动切断阀；故A、C正确，D错误；2储油间的油箱应密闭且应设置通向室外的通气管，通气管应设置带阻火器的呼吸阀，油箱的下部应设置防止油品流散的设施。故B正确，E选项“通向室内”错误，即E错误。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]