[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933802":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},933802,604,1,"单选题","下列关于罐区防火设计要求说法错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","甲、乙、丙类液体储罐区，应布置在城市（区域）的边缘或相对独立的安全地带",false,{"key":16,"text":17,"correct":18},"B","可燃、助燃气体储罐区和可燃材料堆场等，宜布置在城市（区域）全年最小频率风向的下风侧",true,{"key":20,"text":21,"correct":14},"C","甲、乙、丙类液体储罐（区）宜布置在地势较低的地带",{"key":23,"text":24,"correct":14},"D","液化石油气储罐（区）宜布置在地势平坦、开阔等不易积存液化石油气的地带","根据《建筑设计防火规范》（GB50016—2014）第4．1．1条规定，甲、乙、丙类液体储罐区，液化石油气储罐区，可燃、助燃气体储罐区和可燃材料堆场等，应布置在城市（区域）的边缘或相对独立的安全地带，并宜布置在城市（区域）全年最小频率风向的上风侧。甲、乙、丙类液体储罐（区）宜布置在地势较低的地带。当布置在地势较高的地带时，应采取安全防护设施。液化石油气储罐（区）宜布置在地势平坦、开阔等不易积存液化石油气的地带。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]