[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933783":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},933783,604,1,"单选题","下列关于可燃液体储罐布置的说法，不正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","在同一罐组内，单罐容积大于或等于1000m3时，火灾危险性类别不同的储罐不可同组布置",true,{"key":16,"text":17,"correct":18},"B","沸溢性液体的储罐不应与非沸溢性液体储罐同组布置",false,{"key":20,"text":21,"correct":18},"C","可燃液体的压力储罐可与液化烃的全压力储罐同组布置",{"key":23,"text":24,"correct":18},"D","可燃液体的低压储罐可与常压储罐同组布置","根据《石油化工企业设计防火规范》GB 50160—20086.2.5 储罐应成组布置，并应符合下列规定： 1. 在同一罐组内，宜布置火灾危险性类别相同或相近的储罐；当单罐容积小于或等于1000m3时，火灾危险性类别不同的储罐也可同组布置； 2. 沸溢性液体的储罐不应与非沸溢性液体储罐同组布置； 3. 可燃液体的压力储罐可与液化烃的全压力储罐同组布置； 4. 可燃液体的低压储罐可与常压储罐同组布置。 本题答案为A。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]