[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933760":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},933760,604,1,"单选题","市政消火栓应布置在消防车易于接近的人行道和绿地等地点，且不应妨碍交通。距路边不宜小于0．5m，并不应大于（）m。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","1",false,{"key":16,"text":17,"correct":18},"B","2",true,{"key":20,"text":21,"correct":14},"C","3",{"key":23,"text":24,"correct":14},"D","5","根据《消防给水及消火栓系统技术规范》（GB50974—2014）第7．2．6条规定，市政消火栓应布置在消防车易于接近的人行道和绿地等地点，且不应妨碍交通，并应符合下列规定： 1 市政消火栓距路边不宜小于0.5m，并不应大于2.0m； 2 市政消火栓距建筑外墙或外墙边缘不宜小于5.0m； 3 市政消火栓应避免设置在机械易撞击的地点，确有困难时，应采取防撞措施。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]