[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933735":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},933735,604,1,"单选题","下列有关稳压泵选取的说法，错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","稳压泵一般选用大流量、高扬程的水泵",true,{"key":16,"text":17,"correct":18},"B","稳压泵宜采用离心泵，泵外壳和叶轮等主要部件的材质宜采用不锈钢",false,{"key":20,"text":21,"correct":18},"C","稳压泵的设计压力需要满足系统自动启动和管网充满水的要求",{"key":23,"text":24,"correct":18},"D","稳压泵的设计流量应满足消防给水系统管网的正常泄漏量和系统自动启动流量","稳压泵是指在消防给水系统中用于稳定平时最不利点水压的给水泵，稳压泵通常是选用小流量、高扬程的水泵，A选项错误；根据《消防给水及消火栓系统技术规范》GB50974—20145．3．1，稳压泵宜采用离心泵，并宜符合下列规定：宜采用单吸单级或单吸多级离心泵；泵外壳和叶轮等主要部件的材质宜采用不锈钢，B选项正确；根据5．3．3—1，稳压泵的设计压力应满足系统自动启动和管网充满水的要求，C选项正确；根据5．3．2—1，稳压泵的设计流量不应小于消防给水系统管网的正常泄漏量和系统自动启动流量。D选项正确。本题答案为A。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]