[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933732":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},933732,604,1,"单选题","根据《消防给水及消火栓系统技术规范》（GB50974--2014）的规定，下列建筑应设备用泵的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","建筑高度为53m的住宅",false,{"key":16,"text":17,"correct":18},"B","建筑高度为51m的办公楼",true,{"key":20,"text":21,"correct":14},"C","室外消防给水设计流量为25L／s的单层图书馆",{"key":23,"text":24,"correct":14},"D","容纳900人的中型剧场","根据《消防给水及消火栓系统技术规范》GB50974—20145．1．10，消防水泵应设置备用泵，其性能应与工作泵性能一致，但下列建筑除外：1）建筑高度小于54m的住宅和室外消防给水设计流量小于或等于25L／s时；2）建筑的室内消防给水设计流量小于或等于10L／s的建筑，AC选项错误；建筑高度51m的综合楼为一类高层公共类建筑，根据表3．5．2，室内用水量不应小于40L／s，B选项正确；根据表3．5．2，座位数800个\u003C剧场≤1200个，室内消火栓设计流量为10L／s，D选项错误。本题答案为B。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]