[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933642":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},933642,604,2,"多选题","某地下超市，建筑面积2000m2，设有室内消火栓系统、自动喷水灭火系统、火灾自动报警系统及防排烟系统。下列关于该场所配置手提式灭火器的说法，正确的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","超市所需灭火器的最小需配灭火级别为18A",true,{"key":16,"text":17,"correct":14},"B","该场所单具灭火器最大保护距离为20m",{"key":19,"text":20,"correct":21},"C","超市单具灭火器最小配置灭火级别为3A",false,{"key":23,"text":24,"correct":14},"D","超市每个设置点灭火器不宜多于5具",{"key":26,"text":27,"correct":21},"E","超市内配置类型为MT的灭火器","ABD","超市内的火灾主要为固体火灾，Q=1．3K×S／U=1．3×0．5×2000／75=17．3≈18A，A选项正确；A类火灾中危险级场所手提式灭火器的最大保护距离为20m，B选项正确；该超市为中危险级场所，单具灭火器最小配置灭火级别为2A，C选项错误；根据《建筑灭火器配置设计规范》GB50140—20056．1．2，每个设置点的灭火器数量不宜多于5具，D选项正确；超市不应采用二氧化碳灭火器，E选项错误。本题答案为ABD。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]