[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933381":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},933381,604,1,"单选题","某展览建筑，建筑面积为3000m2，层高为6m，室内设有格栅吊顶，吊顶镂空面积与吊顶总面积之比为35％，该建筑室内感烟火灾探测器应设置的位置是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","吊顶上方",true,{"key":16,"text":17,"correct":18},"B","吊顶下方",false,{"key":20,"text":21,"correct":18},"C","吊顶上方和吊顶下方",{"key":23,"text":24,"correct":18},"D","根据实际试验结果确定","根据《火灾自动报警系统设计规范》GB50116—20136．2．18，感烟火灾探测器在格栅吊顶场所的设置，应符合下列规定： 1）镂空面积与总面积的比例不大于15％时，探测器应设置在吊顶下方。 2）镂空面积与总面积的比例大于30％时，探测器应设置在吊顶上方。 3）镂空面积与总面积的比例为15％～30％时，探测器的设置部位应根据实际试验结果确定。 4）探测器设置在吊顶上方且火警确认灯无法观察时，应在吊顶下方设置火警确认灯。 本题答案为A。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]