[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933347":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},933347,604,1,"单选题","下列关于局部应用式干粉灭火系统的说法，错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","保护对象周围的空气流动速度不应大于3m／s",true,{"key":16,"text":17,"correct":18},"B","喷头和保护对象之间，喷头喷射角范围内不应有遮挡物",false,{"key":20,"text":21,"correct":18},"C","保护对象为可燃液体时，液面至容器缘口的距离不得小于150mm",{"key":23,"text":24,"correct":18},"D","保护对象有可燃气体，易燃、可燃液体供应源时，启动干粉灭火系统之前或同时，必须切断气体、液体的供应源","根据《干粉灭火系统设计规范》GB50347—20043．1．3，采用局部应用灭火系统的保护对象，应符合下列规定：保护对象周围的空气流动速度不应大于2m／s，必要时，应采取挡风措施；在喷头和保护对象之间，喷头喷射角范围内不应有遮挡物；当保护对象为可燃液体时，液面至容器缘口的距离不得小于150mm，A选项错误，BC选项正确；根据3．1．4．当防护区或保护对象有可燃气体，易燃、可燃液体供应源时，启动干粉灭火系统之前或同时，必须切断气体、液体的供应源，D选项正确。本题答案为A。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]