[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933219":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},933219,604,2,"多选题","某防护区平时有人工作，采用全淹没式二氧化碳气体灭火系统保护，下列关于该系统控制与操作的说法中，错误的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","当采用火灾探测器时，灭火系统的自动控制应在接收到两个独立的火灾信号后才能启动",false,{"key":16,"text":17,"correct":14},"B","系统宜延迟启动，但延迟时间不应大于30s",{"key":19,"text":20,"correct":21},"C","手动操作装置应设在防护区内便于操作的地方",true,{"key":23,"text":24,"correct":14},"D","防护区入口处应设置手动、自动转换控制装置",{"key":26,"text":27,"correct":21},"E","手动、自动转换控制应置于自动控制状态","CE","根据《二氧化碳气体灭火系统设计规范》GB50193—93（2010年版）6．0．2，当采用火灾探测器时，灭火系统的自动控制应在接收到两个独立的火灾信号后才能启动，根据人员疏散要求，宜延迟启动，但延迟时间不应大于30s，AB选项正确；根据6．0．3，手动操作装置应设在防护区外便于操作的地方，C选项错误；根据6．0．3A，对于采用全淹没灭火系统保护的防护区，应在其入口处设置手动、自动转换控制装置；有人工作时，应置于手动控制状态，D选项正确，E选项错误。本题答案为CE。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]