[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933122":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},933122,604,1,"单选题","下列有关防火分隔水幕系统的说法，正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","防火分隔水幕系统采用的是开式喷头或水幕喷头",true,{"key":16,"text":17,"correct":18},"B","防火分隔水幕系统喷头设置点高度不应超过4m",false,{"key":20,"text":21,"correct":18},"C","防火分隔水幕系统喷头的工作压力不应小于0．15MPa",{"key":23,"text":24,"correct":18},"D","防火分隔水幕系统持续喷水时间不应大于系统设置部位的耐火极限的要求","根据《自动喷水灭火系统设计规范》GB50084—20176．1．5—1，防火分隔水幕应采用开式洒水喷头或水幕喷头，A选项正确。根据5．0．14，水幕系统的设计基本参数应符合下表的规定： 注：系统持续喷水时间不应小于系统设置部位的耐火极限要求。 本题答案为A。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]