[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933051":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},933051,604,1,"单选题","下列有关报警阀组设置要求的说法，正确的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","报警阀组宜设在安全及易于操作的地点，报警阀距地面的高度宜为1．1m",false,{"key":16,"text":17,"correct":14},"B","连接报警阀进出口的控制阀应采用蝶阀",{"key":19,"text":20,"correct":14},"C","并联设置雨淋阀组的雨淋系统，其雨淋阀控制腔的入口应设明杆闸阀",{"key":22,"text":23,"correct":24},"D","安装报警阀的部位应设有排水设施",true,"根据《自动喷水灭火系统设计规范》GB50084—20176．2．6，报警阀组宜设在安全及易于操作的地点，报警阀距地面的高度宜为1．2m；设置报警阀的部位应设有排水设施，A选项错误，D选项正确；根据6．2．7，连接报警阀进出口的控制阀应采用信号阀；当不采用信号阀时，控制阀应设锁定阀位的锁具，B选项错误；根据6．2．5，雨淋阀组的电磁阀，其入口应设过滤器，并联设置雨淋阀组的雨淋系统，其雨淋报警阀控制腔的入口应设止回阀，C选项错误。本题答案为D。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]