[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-933047":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},933047,604,2,"多选题","某地下2层商场，每层建筑面积为2500m2，室内最大净空高度为4．8m，建筑内全部设置湿式自动喷水灭火系统，下列关于该自动喷水灭火系统的做法中，不正确的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","系统采用快速响应洒水喷头",false,{"key":16,"text":17,"correct":18},"B","系统的喷水强度为6L／min·m2",true,{"key":20,"text":21,"correct":18},"C","洒水喷头与配水管道采用消防洒水软管连接",{"key":23,"text":24,"correct":18},"D","部分场所采用隐蔽式洒水喷头",{"key":26,"text":27,"correct":18},"E","商场通道上方设有喷头，喷头的上方设有挡水板","BCDE","根据《自动喷水灭火系统设计规范》GB50084—2017附录A，该商场为中危险级Ⅱ级场所；根据6．1．7，地下商业场所设置湿式系统时，宜采用快速响应洒水喷头，A选项正确；根据表5．0．1，中危险级Ⅱ级场所喷水强度不应低于8L／min·m2，B选项错误；根据8．0．4—1，消防洒水软管仅适用于轻危险级或中危险级Ⅰ级场所，C选项错误；根据6．1．3—7，湿式系统不宜选用隐蔽式洒水喷头，确需采用时，应仅适用于轻危险级或中危险级Ⅰ级场所，D选项错误；根据7．1．10，通道上方设置的喷头上方不应采用挡水板，E选项错误。本题答案为BCDE。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]