[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932976":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},932976,604,2,"多选题","某8层住宅建筑，层高3m，首层地面标高±0．000m，室外地坪标高-0．600m，平屋面面层标高24．200mm。对该建筑外墙进行保温设计，下列选用的保温材料和方式中，符合规范的有（）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","除楼梯间外，内保温材料采用燃烧性能为B1级的聚氨酯泡沫板",false,{"key":16,"text":17,"correct":18},"B","外保温体系与基层墙体无空腔，保温材料采用矿棉板",true,{"key":20,"text":21,"correct":14},"C","除楼梯间外，内保温材料采用燃烧性能为B2级的聚乙烯泡沫板",{"key":23,"text":24,"correct":18},"D","外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B1级的聚氨酯泡沫板",{"key":26,"text":27,"correct":18},"E","外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B1级的聚苯乙烯泡沫板","BDE","根据《建筑设计防火规范》第6．7．2条规定，建筑外墙采用内保温系统时，除人员密集场所外的其他场所，应采用低烟、低毒且燃烧性能不低于B1级的保温材料，聚氨酯泡沫板有毒，故不选A，不选C。第6．7．5条规定，与基层墙体、装饰层之间无空腔的建筑外墙外保温系统，对于建筑高度不大于27m的住宅建筑，保温材料的燃烧性能不应低于B2级，故选B、D、E。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]