[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932972":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},932972,604,2,"多选题","某建筑高度为34m的财贸金融楼，每层建筑面积为3000m2，设置火灾自动报警系统和自动灭火系统等，下列关于该建筑有窗办公室内部装修的做法中，正确的有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","墙面采用墙布",false,{"key":16,"text":17,"correct":18},"B","地面铺装水泥木丝板",true,{"key":20,"text":21,"correct":18},"C","窗帘采用纯毛装饰布",{"key":23,"text":24,"correct":14},"D","顶棚采用矿棉板",{"key":26,"text":27,"correct":18},"E","隔断采用玻璃钢","BCE","根据《建筑内部装修设计防火规范》GB 50222—2017表5．2．1，一类财贸金融楼的顶棚、墙面装修材料燃烧性能等级不应低于A级，地面、隔断、窗帘燃烧性能等级不应低于B1级，根据5．5．2，除本规范第4章规定的场所和本规范表5.2.1中序号为10~12规定的部位外，高层民用建筑的裙房内面积小于500m2的房间，当设有自动灭火系统，并且采用耐火极限不低于2.00h的防火隔墙和甲级防火门、窗与其他部位分隔时，顶棚、墙面、地面装修材料的燃烧性能等级可在本规范表5.2.1规定的基础上降低一级。 故墙布燃烧性能属于B2级，A选项错误；水泥木丝板燃烧性能属于B1级，B选项正确；纯毛装饰布燃烧性能属于B2级，C选项正确；矿棉板燃烧性能属于B1级，D选项错误；玻璃钢燃烧性能属于B2级，E选项正确。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]