[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932880":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},932880,604,1,"单选题","下列关于厂房、仓库防爆技术措施的说法，不正确的是（）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","散发较空气轻的可燃气体、可燃蒸气的甲类厂房，宜采用轻质屋面板作为泄压面积",false,{"key":16,"text":17,"correct":14},"B","使用和生产甲、乙、丙类液体的厂房，其管、沟不应与相邻厂房的管、沟相通，下水道应设置隔油设施",{"key":19,"text":20,"correct":21},"C","甲、乙、丙类液体仓库设置地沟时，其盖板应严密",true,{"key":23,"text":24,"correct":14},"D","散发较空气重的可燃气体、可燃蒸气的甲类厂房和有粉尘、纤维爆炸危险的乙类厂房应采用不发火花的地面","根据《建筑设计防火规范》GB50016—2014（2018年版）3．6．5，散发较空气轻的可燃气体、可燃蒸气的甲类厂房，宜采用轻质屋面板作为泄压面积，A选项正确；根据3．6．11，使用和生产甲、乙、丙类液体的厂房，其管、沟不应与相邻厂房的管、沟相通，下水道应设置隔油设施，B选项正确；根据3．6．12，甲、乙、丙类液体仓库应设置防止液体流散的设施．C选项错误；根据3．6．6—1，散发较空气重的可燃气体、可燃蒸气的甲类厂房和有粉尘、纤维爆炸危险的乙类厂房，应采用不发火花的地面。采用绝缘材料作整体面层时，应采取防静电措施，D选项正确。本题答案为C。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]