[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932827":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},932827,604,1,"单选题","下列关于疏散门设置要求的描述中，正确的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","除甲、乙类生产车间和储存仓库外，人数不超过60人且每樘门的平均疏散人数不超过20人的房间，其疏散门的开启方向不限",false,{"key":16,"text":17,"correct":14},"B","乙类仓库首层靠墙的外侧可采用推拉门或卷帘门",{"key":19,"text":20,"correct":21},"C","疏散走道在防火分区处应设置常开甲级防火门",true,{"key":23,"text":24,"correct":14},"D","厂房的疏散门的总净宽度应经计算确定，门的最小净宽度不宜小于1．20m","选项A错误，民用建筑和厂房的疏散门应向疏散方向开启。除甲、乙类生产车间外，人数不超过60人且每樘门的平均疏散人数不超过30人的房间，其门的开启方向不限。 选项B错误，仓库的疏散门应为向疏散方向开启的平开门，但丙、丁、戊类仓库首层靠墙的外侧可采用推拉门或卷帘门。 选项C正确。 选项D错误，厂房内疏散门的最小净宽度不宜小于0.9m，首层外门的总净宽度应按该层及以上疏散人数最多一层的疏散人数计算，且该门的最小净宽度不应小于1．20m。 本题选C",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]