[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932811":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},932811,604,1,"单选题","某二级耐火等级的乙类厂房，地上2层，地上一、二层的设计疏散人数分别为100人、110人，则厂房二层疏散走道的总净宽度不应小于（ ）m。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","1．1",false,{"key":16,"text":17,"correct":14},"B","1．2",{"key":19,"text":20,"correct":21},"C","1．4",true,{"key":23,"text":24,"correct":14},"D","1．6","根据《建筑设计防火规范》GB 50016—2014（2018年版）3．7．5，厂房内疏散楼梯、走道、门的各自总净宽度，应根据疏散人数按每100人的最小疏散净宽度不小于表3．7．5的规定计算确定。但疏散楼梯的最小净宽度不宜小于1．10m，疏散走道的最小净宽度不宜小于1．40m，门的最小净宽度不宜小于0．90m。当每层疏散人数不相等时，疏散楼梯的总净宽度应分层计算，下层楼梯总净宽度应按该层及以上疏散人数最多一层的疏散人数计算。建筑层数为2层的厂房，每百人疏散宽度指标为0．6m，地上二层疏散走道净宽度为：110×0．6／100=0．66m，应该按最小净宽度1．40m确定。本题答案为C。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]