[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932651":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},932651,604,1,"单选题","某综合楼，共10层，一至三层为商场，三层以上为住宅，当建筑内全部设置自动喷水灭火系统时，住宅与非住宅相接处上下层开口之间应设置挑出宽度不小于（ ）m的防火挑檐。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","0．5",false,{"key":16,"text":17,"correct":14},"B","0．8",{"key":19,"text":20,"correct":21},"C","1．0",true,{"key":23,"text":24,"correct":14},"D","1．2","根据《建筑设计防火规范》GB 50016—2014（2018年版）6．2．5，除本规范另有规定外，建筑外墙上、下层开口之间应设置高度不小于1．2m的实体墙或挑出宽度不小于1．0m、长度不小于开口宽度的防火挑檐；当室内设置自动喷水灭火系统时，上、下层开口之间的实体墙高度不应小于0.8m。当上、下层开口之间设置实体墙确有困难时，可设置防火玻璃墙，但高层建筑的防火玻璃墙的耐火完整性不应低于1.00h，多层建筑的防火玻璃墙的耐火完整性不应低于0.50h。外窗的耐火完整性不应低于防火玻璃墙的耐火完整性要求。本题答案为C。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]