[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932275":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},932275,604,2,"多选题","（2019年真题）火力发电厂的液氨储罐区应（）",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","设置不低于2.0m的不燃烧实体围墙",false,{"key":16,"text":17,"correct":18},"B","位于厂区全年最小频率风向的上风侧",true,{"key":20,"text":21,"correct":14},"C","与厂外道路保持15m以上的防火间距",{"key":23,"text":24,"correct":18},"D","布置在通风良好的厂区边缘地带",{"key":26,"text":27,"correct":18},"E","避开人员集中活动场所和主要人流出入口","BDE","P509-513 根据《火力发电厂与变电站设计防火标准》（GB50229-2019）中第4.0.13条规定，液氨区的布置应符合下列规定: 1 液氨区应单独布置在通风条件良好的厂区边缘地带，避开人员集中活动场所和主要人流出入口，并宜位于厂区全年最小频率风向的上风侧； 2 液氨区应设置不低于2.2m高的不燃烧体实体围墙；当利用厂区围墙作为氨区的围墙时，该段围墙应采用不低于2.5m高的不燃烧体实体围墙； 3 液氨储罐应设置防火堤，防火堤的设置应符合现行国家标准《建筑设计防火规范》GB 50016及《储罐区防火堤设计规范》GB 50351的有关规定。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]