[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932268":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},932268,604,2,"多选题","（2019年真题）为了 节约用地，减少管线投资并方便操作管理，满足一定安全条件的甲、乙、丙类液体储罐可成组布置。关于液化烃地上储罐成组布置的说法，正确的有（）",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","组内全冷式结罐不应多于10个",false,{"key":16,"text":17,"correct":18},"B","组内的储罐不应超过2排",true,{"key":20,"text":21,"correct":18},"C","全冷冻式储罐应单独成组布置",{"key":23,"text":24,"correct":14},"D","组内全压力式储罐不应多于10个",{"key":26,"text":27,"correct":18},"E","储罐不能适应罐组内任一介质泄漏所产生的最低温度时，不应布置在同一罐组内","BCE","P491-506 根据《石油化工企业设计防火标准》（GB50160-2008（2108版））中第6.3.2条规定， 液化烃储罐成组布置时应符合下列规定： 1 液化烃罐组内的储罐不应超过2排； 2 每组全压力式或半冷冻式储罐的个数不应多于12个； 3 全冷冻式储罐的个数不宜多于2个； 4 全冷冻式储罐应单独成组布置； 5 储罐不能适应罐组内任一介质泄漏所产生的最低温度时，不应布置在同一罐组内。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]