[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-932046":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},932046,604,2,"多选题","（2018真题）下列办公建筑内会议厅的平面布置方案中，正确的有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","耐火等级为二级的办公建筑，将建筑面积为 300 ㎡的会议厅布置在地下一层",false,{"key":16,"text":17,"correct":14},"B","耐火等级为一级的办公建筑，将建筑面积为 600 ㎡的会议厅布置在地上四层",{"key":19,"text":20,"correct":21},"C","耐火等级为一级的办公建筑，将建筑面积为 200 ㎡的会议厅布置在地下二层",true,{"key":23,"text":24,"correct":21},"D","耐火等级为二级的办公建筑，将建筑面积为 500 ㎡的会议厅布置在地上三层",{"key":26,"text":27,"correct":14},"E","耐火等级为三级的办公建筑，将建筑面积为 200 ㎡的会议厅布置在地上三层","CD","耐火等级为一二级的办公建筑，地下和地上四层及以上楼层，面积不宜超过400㎡，地下建筑的耐火等级应为一级，AB 错误，三级耐火等级，会议厅最多布置在二层，E错误。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]