[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-931957":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},931957,604,1,"单选题","（2018真题）下列关于城市消防远程监控系统设计正确的是（）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","城市消防远程监控系统应能同时接收和处理不少于3个联网用户的火灾报警信息",true,{"key":16,"text":17,"correct":18},"B","城市消防远程监控系统向城市消防通信指挥中心或其他接处警中心转发经确认的火灾报警信息的时间不应大于5s",false,{"key":20,"text":21,"correct":18},"C","城市消防远程监控系统的火灾报警信息、建筑消防设施运行状态信息等记录应备份，其保存周期不应小于6个月",{"key":23,"text":24,"correct":18},"D","城市消防远程监控系统录音文件的保存周期不应少于3个月","城市消防远程监控系统向城市消防通信指挥中心或其他接处警中心转发经确认的火灾报警信息的时间不应大于3s 每年对监控中心的火灾报警信息、建筑消防设施运行状态信息等记录进行备份，必要时清理保存周期超过1 年的备份信息。 每半年检查录音文件的保存情况，必要时清理保存周期超过6 个月的录音文件。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]