[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-931702":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},931702,604,2,"多选题","（2015真题）某建筑高度为23.8m的4层商业建筑，对其进行室内消火栓的配置和设计中，正确的有（）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","选用DN65的室内消火栓",true,{"key":16,"text":17,"correct":18},"B","消火栓栓口动压大于0.5MPa",false,{"key":20,"text":21,"correct":14},"C","消火栓栓口动压不小于0.25MPa",{"key":23,"text":24,"correct":18},"D","配置直径65mm长30m的消防水带",{"key":26,"text":27,"correct":14},"E","水枪充实水柱不小于10m","ACE","应采用DN65mm的室内消火栓，选项A正确。配置公称直径65mm有内衬里的消防水带，长度不宜超过25m，选项E错误。本题中的建筑为建筑高度为23．8m的4层商业建筑，属于低、多层建筑，消火栓栓口动压不应小于0．25MPa，选项B错误、选项C正确，消防水枪充实水柱应达到10m，选项E正确。",{"id":6,"name":31,"category":32,"favorite":33},"消防安全技术实务(一级)","建筑工程",0]