[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":573},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,3,50,1330,[13,34,46,58,68,80,92,102,114,122,134,146,158,166,178,190,202,214,226,238,250,262,272,284,296,308,320,332,344,354,366,376,387,398,410,420,432,443,455,463,471,479,489,500,512,522,533,545,555,563],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},928652,1,"单选题","如图所示，某钢筋混凝土现浇肋形楼盖的次梁，跨中承受最大正弯矩设计值M＝115kN·m。混凝土强度等级为C30，纵向受拉钢筋采用热轧HRB335钢筋。楼板厚度h f′＝80mm，次梁高度h＝450mm，宽度b＝200mm，纵向受力钢筋合力点至混凝土边缘的距离a s′＝35mm。 2.若已知翼缘计算宽度b f′＝1800mm，则按单筋T形截面计算的次梁跨中所需受拉钢筋计算截面面积最接近于（ ）mm2。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","940",false,{"key":24,"text":25,"correct":26},"B","1009",true,{"key":28,"text":29,"correct":22},"C","1033",{"key":31,"text":32,"correct":22},"D","1124","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},928653,"如图所示，某钢筋混凝土现浇肋形楼盖的次梁，跨中承受最大正弯矩设计值M＝115kN·m。混凝土强度等级为C30，纵向受拉钢筋采用热轧HRB335钢筋。楼板厚度h f′＝80mm，次梁高度h＝450mm，宽度b＝200mm，纵向受力钢筋合力点至混凝土边缘的距离a s′＝35mm。 1.若已知次梁的计算跨度l0＝6m，间距为2.4m，净距sn＝2.2m，则翼缘的计算宽度bf′最接近于（ ）mm。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1800",{"key":24,"text":41,"correct":26},"2000",{"key":28,"text":43,"correct":22},"2200",{"key":31,"text":45,"correct":22},"2400",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},928654,"某框架结构中间楼层端部梁柱节点如图所示，框架抗震等级为二级，梁柱混凝土强度等级均为C35，框架梁上部纵筋为 弯折前的水平段长l1=560mm。试问，框架梁上部纵筋满足抗震构造要求的最小总锚固长度l（mm）与下列何项数值最为接近？（ ）[2013年真题]",[50,52,54,56],{"key":20,"text":51,"correct":26},"980",{"key":24,"text":53,"correct":22},"1086",{"key":28,"text":55,"correct":22},"1195",{"key":31,"text":57,"correct":22},"1245",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},928655,"某框架结构顶层端节点处框架梁截面尺寸为300mm×700mm，混凝土强度等级为C30，as=as′=60mm，纵筋采用HRB500钢筋。试问，为防止框架顶层端节点处梁上部钢筋配筋率过高而引起节点核心区混凝土的斜压破坏，框架梁上部纵向钢筋的最大配筋量（mm2）应与下列何项数值最为接近？（ ）[2013年真题]",[62,64,65,66],{"key":20,"text":63,"correct":22},"1500",{"key":24,"text":39,"correct":22},{"key":28,"text":43,"correct":26},{"key":31,"text":67,"correct":22},"2500",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":28,"analysis":33},928656,"某框架结构办公楼中的楼面长悬臂梁，悬挑长度5m，梁上承受的恒载标准值为32kN／m（包括梁自重），按等效均布荷载计算的活荷载标准值为8kN／m，梁端集中恒荷载标准值为30kN。已知，抗震设防烈度为8度，设计基本地震加速度值为0.20g，程序计算分析时未作竖向地震计算。试问，当用手算复核该悬挑梁配筋设计时，其支座考虑地震作用组合的弯矩设计值M（kN·m），与下列何项数值最为接近？（ ）[2014年真题]",[72,74,76,78],{"key":20,"text":73,"correct":22},"600",{"key":24,"text":75,"correct":22},"720",{"key":28,"text":77,"correct":26},"800",{"key":31,"text":79,"correct":22},"850",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":20,"analysis":33},928657,"某钢筋混凝土连续梁，截面高度为3900mm，截面宽度为300mm，计算跨度为6000mm，混凝土强度等级为C40，不考虑抗震。梁的水平和竖向分布筋配置符合规范要求。试问，此梁要求不出现斜裂缝时，中间支座截面对应于标准组合的抗剪承载力（kN）与下列何项数值最为接近？（ ）[2012年真题] 提示：结构安全等级二级。",[84,86,88,90],{"key":20,"text":85,"correct":26},"1120",{"key":24,"text":87,"correct":22},"1250",{"key":28,"text":89,"correct":22},"1380",{"key":31,"text":91,"correct":22},"2680",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":24,"analysis":33},928658,"某单跨简支独立梁受力简图如图所示。简支梁截面尺寸为300mm×850mm（ho=815mm），混凝土强度等级为C30，梁箍筋采用HPB300钢筋，安全等级为二级。[2013年真题]",[96,98,99,101],{"key":20,"text":97,"correct":22},"1.假定，该梁承受的剪力设计值V=260kN。试问，下列梁箍筋配置何项满足《混凝土结构设计规范》（G50010—2010）的构造要求？（ ）",{"key":24,"text":33,"correct":26},{"key":28,"text":100,"correct":22},"提示：假定，以下各项均满足计算要求。",{"key":31,"text":33,"correct":22},{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":28,"analysis":33},928659,"某单跨简支独立梁受力简图如图所示。简支梁截面尺寸为300mm×850mm（ho=815mm），混凝土强度等级为C30，梁箍筋采用HPB300钢筋，安全等级为二级。[2013年真题] 假定，集中力设计值F=250kN，均布荷载设计值q=15kN／m。试问，当箍筋为10@200（2）时，梁斜截面受剪承载力设计值（kN），与下列何项数值最为接近？（ ）",[106,108,110,112],{"key":20,"text":107,"correct":22},"250",{"key":24,"text":109,"correct":22},"300",{"key":28,"text":111,"correct":26},"350",{"key":31,"text":113,"correct":22},"400",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},928660,"钢筋混凝土简支梁，混凝土强度等级为C30。纵向受力钢筋用HRB335级，箍筋用HPB300级。梁截面为300mm×600mm，计算配筋为As＝2700.0mm2，则梁的纵向受拉钢筋配置最合适的是（ ）。",[118,119,120,121],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":28,"analysis":33},928661,"T形截面梁（见图），b f′＝500mm，b＝200mm，h f′＝80mm，h＝600mm，as＝40mm，混凝土强度等级为C25，纵向受拉钢筋为HRB335级，用4Φ22，As＝1520mm2，则此梁所能承受的弯矩Mu为（ ）kN·m。",[126,128,130,132],{"key":20,"text":127,"correct":22},"211.68",{"key":24,"text":129,"correct":22},"237.12",{"key":28,"text":131,"correct":26},"237.80",{"key":31,"text":133,"correct":22},"247.52",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":31,"analysis":33},928662,"钢筋混凝土T形截面构件如图所示，b＝250mm，h＝500mm，b f′＝400mm，hf′＝150mm，混凝土强度等级为C30，纵筋采用HRB335钢筋，箍筋采用HPB300钢筋。受扭纵筋与箍筋的配筋强度比值为ζ＝1.2，Acor＝90000mm2。 3.设构件承受剪力设计值V＝80kN，箍筋间距s＝100mm，受扭纵筋与箍筋的配筋强度比值为ζ＝1.2，腹板的塑性抵抗矩Wtw和所受扭矩Tw的比值为0.98，已知构件须按剪扭构件计算，则腹板的抗剪箍筋的计算面积Asv最接近于（ ）mm2。",[138,140,142,144],{"key":20,"text":139,"correct":22},"50",{"key":24,"text":141,"correct":22},"29",{"key":28,"text":143,"correct":22},"25",{"key":31,"text":145,"correct":26},"14",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":24,"analysis":33},928663,"非预应力钢筋混凝土屋架如图2-36所示。已知集中荷载P＝GK＋QK，静载GK＝10.5kN（包括构件自重），活载QK＝9.6kN。提示：活载标准值大于4.0kN\u002Fm2，计算屋架杆件内力时不考虑节点次应力的影响。 2.在静载和活载共同作用下，上弦杆S1的内力设计值最接近于（ ）kN。",[150,152,154,156],{"key":20,"text":151,"correct":22},"134.83",{"key":24,"text":153,"correct":26},"140.20",{"key":28,"text":155,"correct":22},"145.57",{"key":31,"text":157,"correct":22},"151.69",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":28,"analysis":33},928664,"非预应力钢筋混凝土屋架如图2-36所示。已知集中荷载P＝GK＋QK，静载GK＝10.5kN（包括构件自重），活载QK＝9.6kN。提示：活载标准值大于4.0kN\u002Fm2，计算屋架杆件内力时不考虑节点次应力的影响。 3.若上弦杆截面尺寸均为b×h＝250mm×250mm，采用C35级混凝土，纵向受力钢筋采用HRB335级。设上弦杆S3轴向力设计值N＝148.72kN，计算长度l0＝2500mm，则承载力计算时其全截面纵向受力钢筋面积最接近于（ ）。",[162,163,164,165],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},928665,"某24层高层住宅楼，首层层高3.25m，结构总高度66.80m，采用钢筋混凝土全现浇剪力墙结构。底层某矩形剪力墙混凝土强度等级为C35，墙体端部约束边缘构件纵向受力钢筋采用HRB400级，墙体分布钢筋和端部约束边缘构件箍筋采用HRB335级。 4.题（3）中，若b×h=220mm×3000mm，h0=2800mm，控制内力设计值N＝330.1kN，M=865.8kN·m，V=227.2kN，则此墙肢的水平分布钢筋可选用（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"φ6@200",{"key":24,"text":173,"correct":22},"φ8@200",{"key":28,"text":175,"correct":26},"φ10@200",{"key":31,"text":177,"correct":22},"φ12@200",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},928666,"某24层高层住宅楼，首层层高3.25m，结构总高度66.80m，采用钢筋混凝土全现浇剪力墙结构。底层某矩形剪力墙混凝土强度等级为C35，墙体端部约束边缘构件纵向受力钢筋采用HRB400级，墙体分布钢筋和端部约束边缘构件箍筋采用HRB335级。 5.题（4）中，若墙肢的控制组合内力设计值M=865.8kN·m，N=330.1kN。墙肢配置竖向分布钢筋双排），竖向分布钢筋配筋率为ρw=0.357%。墙肢的约束边缘构件阴影部分长度hc＝400mm，则此墙肢约束边缘构件阴影部分的纵向受力钢筋可选用（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"4Φ16",{"key":24,"text":185,"correct":22},"4Φ18",{"key":28,"text":187,"correct":26},"6Φ14",{"key":31,"text":189,"correct":22},"6Φ16",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":31,"analysis":33},928667,"钢筋混凝土简支矩形截面梁尺寸为250mm×500mm，混凝土强度等级为C30，梁受拉区配置3Φ20的钢筋（As=942mm2），混凝土保护层c＝25mm，承受均布荷载，梁的计算跨度l0＝6m。 1.若已知按荷载效应的准永久组合计算的跨中弯矩值Mq＝100kN·m，则裂缝间纵向受拉钢筋应变不均匀系数ψ最接近于（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"0.580",{"key":24,"text":197,"correct":22},"0.635",{"key":28,"text":199,"correct":22},"0.660",{"key":31,"text":201,"correct":26},"0.771",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},928668,"钢筋混凝土简支矩形截面梁尺寸为250mm×500mm，混凝土强度等级为C30，梁受拉区配置3Φ20的钢筋（As=942mm2），混凝土保护层c＝25mm，承受均布荷载，梁的计算跨度l0＝6m。 2.若已知裂缝间纵向受拉钢筋应变不均匀系数ψ＝0.825，则该梁的短期效应刚度最接近于（ ）kN·m2。",[206,208,210,212],{"key":20,"text":207,"correct":26},"27657",{"key":24,"text":209,"correct":22},"22702",{"key":28,"text":211,"correct":22},"22610",{"key":31,"text":213,"correct":22},"23610",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},928669,"钢筋混凝土简支矩形截面梁尺寸为250mm×500mm，混凝土强度等级为C30，梁受拉区配置3Φ20的钢筋（As=942mm2），混凝土保护层c＝25mm，承受均布荷载，梁的计算跨度l0＝6m。 若已知梁的短期效应刚度Bs＝29732.14kN·m2，按荷载效应的标准组合计算的跨中弯矩值Mk＝90kN·m，按荷载效应的准永久组合计算的跨中弯矩值Mq＝50kN·m，梁受压区配有218的钢筋，则跨中挠度最接近于（ ）mm。",[218,220,222,224],{"key":20,"text":219,"correct":22},"10.2",{"key":24,"text":221,"correct":22},"14.3",{"key":28,"text":223,"correct":26},"16.3",{"key":31,"text":225,"correct":22},"17.9",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":33},928670,"某单层等高等跨厂房，排架结构图所示，安全等级为二级。厂房长度为66m，排架间距B=6m，两端山墙，采用砖围护墙及钢屋架，屋面支撑系统完整。柱及牛腿混凝土强度等级为C30，纵筋采用HRB400。[2013年真题] 1.假定，厂房所在地区基本风压w0=0.45kN／m2，场地平坦，地面粗糙度为B类，室外地坪标高为－0.300m。试问，厂房中间一榀排架的屋架传给排架柱顶的风荷载标准值Wk（kN），与下列何项数值最为接近？（ ） 提示：βz=1.0，风压高度系数μz按柱顶标高取值。",[230,232,234,236],{"key":20,"text":231,"correct":22},"6.0",{"key":24,"text":233,"correct":26},"6.6",{"key":28,"text":235,"correct":22},"7.1",{"key":31,"text":237,"correct":22},"8.0",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},928671,"某单层等高等跨厂房，排架结构图所示，安全等级为二级。厂房长度为66m，排架间距B=6m，两端山墙，采用砖围护墙及钢屋架，屋面支撑系统完整。柱及牛腿混凝土强度等级为C30，纵筋采用HRB400。[2013年真题] 当计算厂房纵向地震作用时，按《建筑抗震设计规范》（GB 50011—2010）估算的厂房纵向基本周期T（s），与下列何项数值最为接近？（ ）",[242,244,246,248],{"key":20,"text":243,"correct":26},"0.4",{"key":24,"text":245,"correct":22},"0.6",{"key":28,"text":247,"correct":22},"0.8",{"key":31,"text":249,"correct":22},"1.1",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":33},928672,"某单层等高等跨厂房，排架结构图所示，安全等级为二级。厂房长度为66m，排架间距B=6m，两端山墙，采用砖围护墙及钢屋架，屋面支撑系统完整。柱及牛腿混凝土强度等级为C30，纵筋采用HRB400。[2013年真题] 假定，柱A下柱截面b×h为400mm×600mm，非抗震设计时，控制配筋的内力组合弯矩设计值M=250kN·m，相应的轴力设计值N=500kN，采用对称配筋，as=as′=40mm，相对受压区高度为ξb=0.518，初始偏心距ei=520mm。试问，柱一侧纵筋截面面积As（mm2），与下列何项数值最为接近？（ ）",[254,256,258,260],{"key":20,"text":255,"correct":22},"480",{"key":24,"text":257,"correct":22},"610",{"key":28,"text":259,"correct":26},"710",{"key":31,"text":261,"correct":22},"920",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":28,"analysis":33},928673,"某单层等高等跨厂房，排架结构图所示，安全等级为二级。厂房长度为66m，排架间距B=6m，两端山墙，采用砖围护墙及钢屋架，屋面支撑系统完整。柱及牛腿混凝土强度等级为C30，纵筋采用HRB400。[2013年真题] 假定，柱B牛腿如图2-8所示，牛腿顶部的竖向力设计值Fv=450kN，牛腿截面有效高度h0=950mm，宽度b=400mm，牛腿的截面尺寸满足裂缝控制要求。试问，牛腿纵向受拉钢筋截面面积As（mm2），与下列何项数值最为接近？（ ）",[266,268,269,270],{"key":20,"text":267,"correct":22},"500",{"key":24,"text":73,"correct":22},{"key":28,"text":77,"correct":26},{"key":31,"text":271,"correct":22},"1000",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":24,"analysis":33},928674,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 1.试问，该防震缝的宽度δ（mm）至少应取下列何项数值？（ ）",[276,278,280,282],{"key":20,"text":277,"correct":22},"110",{"key":24,"text":279,"correct":26},"140",{"key":28,"text":281,"correct":22},"150",{"key":31,"text":283,"correct":22},"180",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":31,"analysis":33},928675,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 2.关关于抗撞墙的布置及设计，下列所述何项正确？（ ）",[288,290,292,294],{"key":20,"text":289,"correct":22},"在缝两侧沿房屋全高各设置不少于一道垂直于防震缝的抗撞墙",{"key":24,"text":291,"correct":22},"抗撞墙的布置宜避免加大扭转效应，其长度应大于1\u002F2层高",{"key":28,"text":293,"correct":22},"抗撞墙的抗震等级应比其框架结构提高一级",{"key":31,"text":295,"correct":26},"框架构件的内力应按设置和不设置抗撞墙两种计算模型的不利情况取值",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":20,"analysis":33},928676,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 5.已知：A栋房屋的抗震等级为二级，A栋底层中柱KZl的柱净高Hn=2.5m，柱上节点梁端截面顺时针或逆时针方向组合的弯矩设计值∑Mb=360kN·m，柱下端截面组合的弯矩设计值Mn=320kN·m，反弯点在柱层高范围内，柱轴压比为0.5。试问，为实现“强柱弱梁”及“强剪弱弯”，按规范调整后该柱的组合剪力设计值V（kN），与下列何项数值最为接近？（ ） 提示：①柱上节点上、下柱端的弯矩设计值按平均分配。②",[300,302,304,306],{"key":20,"text":301,"correct":26},"390",{"key":24,"text":303,"correct":22},"430",{"key":28,"text":305,"correct":22},"470",{"key":31,"text":307,"correct":22},"530",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":31,"analysis":33},928677,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 6.已知：B栋底层边柱KZ3截面及配筋示意如图2-20所示，考虑地震作用组合的柱轴压力设计值N=4120kN，该柱剪跨比λ=2.5，该柱混凝土强度等级为C40，箍筋采用HPB235级钢筋，纵向受力钢筋的混凝土保护层厚度c=30mm。如仅从抗震构造措施方面考虑，试问，该柱选用下列何项箍筋配置（复合箍）最为恰当？（ ）提示：按《建筑抗震设计规范》（GB 50011—2010）作答。为简化计算，扣除重叠部分箍筋。",[312,314,316,318],{"key":20,"text":313,"correct":22},"Φ10@100\u002F200",{"key":24,"text":315,"correct":22},"Φ10@100",{"key":28,"text":317,"correct":22},"Φ12@100\u002F200",{"key":31,"text":319,"correct":26},"Φ12@100",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":31,"analysis":33},928678,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 假定，A栋二层中柱KZl截面尺寸b×h=600mm×600mm，ho=555mm。柱净高Hn=2.5m，柱上、下端截面考虑地震作用组合的弯矩计算值分别为Mct=280kN·m、Mcb=470kN·m，弯矩均为顺时针或逆时针方向。试问，该框架柱的剪跨比λ取下列何项数值最为合适？（ ） 提示：采用公式",[324,326,328,330],{"key":20,"text":325,"correct":22},"1.7",{"key":24,"text":327,"correct":22},"2.2",{"key":28,"text":329,"correct":22},"2.6",{"key":31,"text":331,"correct":26},"2.8",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":28,"analysis":33},928679,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 3.经估算，A栋底层中柱KZl考虑地震作用组合的轴压力设计值N=5490kN，假定该柱混凝土强度等级为C40，剪跨比λ=1.8，箍筋采用直径Ф10的井字复合箍（非螺旋箍）且未配置芯柱，试问，该框架柱最小截面尺寸b（mm）×h（mm）选用下列何项时，满足规范最低抗震构造要求？（ ）",[336,338,340,342],{"key":20,"text":337,"correct":22},"550×550",{"key":24,"text":339,"correct":22},"600×600",{"key":28,"text":341,"correct":26},"650×650",{"key":31,"text":343,"correct":22},"700×700",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":28,"analysis":33},928680,"某钢筋混凝土简支梁图，其截面可以简化成工字形，混凝土强度等级为C30，纵向钢筋采用HRB400，纵向钢筋的保护层厚度为28mm，受拉钢筋合力点至梁截面受拉边缘的距离为40mm。该梁不承受地震作用，不直接承受重复荷载，安全等级为二级。[2012年真题]",[348,349,351,353],{"key":20,"text":33,"correct":22},{"key":24,"text":350,"correct":22},"若该梁承受的弯矩设计值为310kN·m，并按单筋梁进行配筋计算。试问，按承载力要求该梁纵向受拉钢筋选择下列何项最为安全经济？（ ）",{"key":28,"text":352,"correct":26},"提示：不必验算最小配筋率。",{"key":31,"text":33,"correct":22},{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":28,"analysis":33},928681,"某钢筋混凝土简支梁图，其截面可以简化成工字形，混凝土强度等级为C30，纵向钢筋采用HRB400，纵向钢筋的保护层厚度为28mm，受拉钢筋合力点至梁截面受拉边缘的距离为40mm。该梁不承受地震作用，不直接承受重复荷载，安全等级为二级。[2012年真题] 若该梁在荷载准永久组合下的短期刚度 且该梁配置的纵向受压钢筋面积为纵向受拉钢筋面积的80％。试问，该梁考虑荷载长期作用影响的刚度 与下列何项数值最为接近？（ ）",[358,360,362,364],{"key":20,"text":359,"correct":22},"1.00",{"key":24,"text":361,"correct":22},"1.04",{"key":28,"text":363,"correct":26},"1.19",{"key":31,"text":365,"correct":22},"1.60",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":28,"analysis":33},928682,"某钢筋混凝土简支梁图，其截面可以简化成工字形，混凝土强度等级为C30，纵向钢筋采用HRB400，纵向钢筋的保护层厚度为28mm，受拉钢筋合力点至梁截面受拉边缘的距离为40mm。该梁不承受地震作用，不直接承受重复荷载，安全等级为二级。[2012年真题] 试问，该梁纵向受拉钢筋的构造最小配筋量（mm2）与下列何项数值最为接近？（ ）",[370,372,374,375],{"key":20,"text":371,"correct":22},"200",{"key":24,"text":373,"correct":22},"270",{"key":28,"text":109,"correct":26},{"key":31,"text":113,"correct":22},{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":378,"answer":24,"analysis":33},928683,[379,381,383,385],{"key":20,"text":380,"correct":22},"3.2",{"key":24,"text":382,"correct":26},"5.3",{"key":28,"text":384,"correct":22},"6.8",{"key":31,"text":386,"correct":22},"8.3",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":389,"answer":28,"analysis":33},928684,[390,392,394,396],{"key":20,"text":391,"correct":22},"0.17",{"key":24,"text":393,"correct":22},"0.29",{"key":28,"text":395,"correct":26},"0.33",{"key":31,"text":397,"correct":22},"0.45",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":28,"analysis":33},928685,"假定，该底层柱下端截面产生的竖向内力标准值如下：由结构和构配件自重荷载产生的NGk=980kN；由按等效均布荷载计算的楼（屋）面可变荷载产生的NQk=220kN，由水平地震作用产生的NEhk=280kN，试问，该底层柱的轴压比μN与轴压比限值[μN]之比，与下列何项数值最为接近？（ ）",[402,404,406,408],{"key":20,"text":403,"correct":22},"0.67",{"key":24,"text":405,"correct":22},"0.80",{"key":28,"text":407,"correct":26},"0.91",{"key":31,"text":409,"correct":22},"0.98",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":412,"answer":24,"analysis":33},928686,[413,415,417,419],{"key":20,"text":414,"correct":22},"假定，该底层柱轴压比为0.5，试问，该底层框架柱柱端加密区的箍筋配置选用下列何项才能满足规程的最低要求？（ ）",{"key":24,"text":416,"correct":26},"提示：①按《混凝土异形柱结构技术规程》（JGJ 149—2006）作答；",{"key":28,"text":418,"correct":22},"②扣除重叠部分箍筋的体积。",{"key":31,"text":33,"correct":22},{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":24,"analysis":33},928687,"假定，该框架边柱底层柱下端截面（基础顶面）有地震作用组合未经调整的弯矩设计值为320kN·m，底层柱上端截面有地震作用组合并经调整后的弯矩设计值为312kN·m，柱反弯点在柱层高范围内。试问，该柱考虑地震作用组合的剪力设计值Vc（kN），与下列何项数值最为接近？（ ） 提示：按《混凝土异形柱结构技术规程》（JGJ 149—2006)作答。",[424,426,428,430],{"key":20,"text":425,"correct":22},"185",{"key":24,"text":427,"correct":26},"222",{"key":28,"text":429,"correct":22},"266",{"key":31,"text":431,"correct":22},"290",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":434,"answer":31,"analysis":33},928688,[435,437,439,441],{"key":20,"text":436,"correct":22},"700",{"key":24,"text":438,"correct":22},"900",{"key":28,"text":440,"correct":22},"1100",{"key":31,"text":442,"correct":26},"1300",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":28,"analysis":33},928689,"已知，框架梁中间支座截面有效高度h0=530mm，试问，图2-3框架梁KL1（2）配筋有几处违反规范的抗震构造要求，并简述理由。（ ） 提示：x／h0",[447,449,451,453],{"key":20,"text":448,"correct":22},"无违反",{"key":24,"text":450,"correct":22},"有一处",{"key":28,"text":452,"correct":26},"有二处",{"key":31,"text":454,"correct":22},"有三处",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":28,"analysis":33},928690,"试问，图 （A）剪力墙Q1配筋及连梁LL1配筋共有几处违反规范的抗震构造要求，并简述理由。（ ） 提示：LL1腰筋配置满足规范要求。",[459,460,461,462],{"key":20,"text":448,"correct":22},{"key":24,"text":450,"correct":22},{"key":28,"text":452,"correct":26},{"key":31,"text":454,"correct":22},{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":28,"analysis":33},928691,"框架柱KZ1剪跨比大于2，配筋如图 （B）所示，试问，图中KZ1有几处违反规范的抗震构造要求，并简述理由。（ ） 提示：KZ1的箍筋体积配箍率及轴压比均满足规范要求。",[467,468,469,470],{"key":20,"text":448,"correct":22},{"key":24,"text":450,"correct":22},{"key":28,"text":452,"correct":26},{"key":31,"text":454,"correct":22},{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":28,"analysis":33},928692,"剪力墙约束边缘构件YBZ1配筋如图 （C）所示，已知墙肢底截面的轴压比为0.4。试问，图中YBZ1有几处违反规范的抗震构造要求，并简述理由。（ ） 提示：YBZ1阴影区和非阴影区的箍筋和拉筋体积配箍率满足规范要求。",[475,476,477,478],{"key":20,"text":448,"correct":22},{"key":24,"text":450,"correct":22},{"key":28,"text":452,"correct":26},{"key":31,"text":454,"correct":22},{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":24,"analysis":33},928693,"不考虑地震作用组合时框架梁KL1的跨中截面及配筋如图 （A）所示，假定，梁受压区有效翼缘计算宽度b'f=2000mm，as=a's=45mm，ξb=0.518，γ0=1.0。试问，当考虑梁跨中纵向受压钢筋和现浇楼板受压翼缘的作用时，该梁跨中正截面受弯承载力设计值M（kN·m），与下列何项数值最为接近？（ ） 提示：不考虑梁上部架立筋及板内配筋的影响。",[483,484,486,488],{"key":20,"text":267,"correct":22},{"key":24,"text":485,"correct":26},"540",{"key":28,"text":487,"correct":22},"670",{"key":31,"text":75,"correct":22},{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":491,"answer":24,"analysis":33},928694,[492,494,496,498],{"key":20,"text":493,"correct":22},"17",{"key":24,"text":495,"correct":26},"22",{"key":28,"text":497,"correct":22},"26",{"key":31,"text":499,"correct":22},"30",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":24,"analysis":33},928695,"某8度区的框架结构办公楼，框架梁混凝土强度等级为C35，均采用HRB400钢筋。框架的抗震等级为一级。A轴框架梁的配筋平面表示法如图2-7所示，as=as′=60mm。①轴的柱为边柱，框架柱截面b×h=800mm×800mm，定位轴线均与梁、柱中心线重合。提示：不考虑楼板内的钢筋作用。 假定，该梁为顶层框架梁。试问，为防止配筋率过高而引起节点核心区混凝土的斜压破坏，KL—1在靠近①轴的梁端上部纵筋最大配筋面积（mm2）的限值与下列何项数值最为接近？（ ）",[504,506,508,510],{"key":20,"text":505,"correct":22},"3200",{"key":24,"text":507,"correct":26},"4480",{"key":28,"text":509,"correct":22},"5160",{"key":31,"text":511,"correct":22},"6900",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":24,"analysis":33},928696,"某8度区的框架结构办公楼，框架梁混凝土强度等级为C35，均采用HRB400钢筋。框架的抗震等级为一级。A轴框架梁的配筋平面表示法如图2-7所示， 假定，该梁为中间层框架梁，作用在此梁上的重力荷载全部为沿梁全长的均布荷载，梁上永久均布荷载标准值为46kN／m（包括自重），可变均布荷载标准值为12kN／m（可变均布荷载按等效均布荷载计算）。试问，此框架梁端考虑地震组合的剪力设计值Vb（kN），应与下列何项数值最为接近？（ ）",[516,517,519,521],{"key":20,"text":305,"correct":22},{"key":24,"text":518,"correct":26},"520",{"key":28,"text":520,"correct":22},"570",{"key":31,"text":73,"correct":22},{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":28,"analysis":33},928697,"某7层住宅，层高均为3.1m，房屋高度22.3m，安全等级为二级，采用现浇钢筋混凝土剪力墙结构，混凝土强度等级为C35，抗震等级三级，结构平面立面均规则。某矩形截面墙肢尺寸bw×hw=250mm×2300mm，各层截面保持不变。 假定，底层作用在该墙肢底面的由永久荷载标准值产生的轴向压力NGk=3150kN，按等效均布荷载计算的活荷载标准值产生的轴向压力NQk=750kN，由水平地震作用标准值产生的轴向压力NEk=900kN。试问，按《建筑抗震设计规范》GB 50011—2010计算，底层该墙肢底截面的轴压比与下列何项数值最为接近？（ ）",[526,528,530,531],{"key":20,"text":527,"correct":22},"0.35",{"key":24,"text":529,"correct":22},"0.40",{"key":28,"text":397,"correct":26},{"key":31,"text":532,"correct":22},"0.55",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":24,"analysis":33},928698,"某7层住宅，层高均为3.1m，房屋高度22.3m，安全等级为二级，采用现浇钢筋混凝土剪力墙结构，混凝土强度等级为C35，抗震等级三级，结构平面立面均规则。某矩形截面墙肢尺寸bw×hw=250mm×2300mm，各层截面保持不变。 假定，该墙肢底层底截面的轴压比为0.58，三层底截面的轴压比为0.38。试问，下列对三层该墙肢两端边缘构件的描述何项是正确的？（ ）",[537,539,541,543],{"key":20,"text":538,"correct":22},"需设置构造边缘构件，暗柱长度不应小于300mm",{"key":24,"text":540,"correct":26},"需设置构造边缘构件，暗柱长度不应小于400mm",{"key":28,"text":542,"correct":22},"需设置约束边缘构件，lc不应小于500mm",{"key":31,"text":544,"correct":22},"需设置约束边缘构件，lc不应小于400mm",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},928699,"某7层住宅，层高均为3.1m，房屋高度22.3m，安全等级为二级，采用现浇钢筋混凝土剪力墙结构，混凝土强度等级为C35，抗震等级三级，结构平面立面均规则。某矩形截面墙肢尺寸bw×hw=250mm×2300mm，各层截面保持不变。 该住宅某门顶连梁截面和配筋如图2-8所示。假定，门洞净宽1000mm，连梁中未配置斜向交叉钢筋。h0=720mm，均采用HRB500钢筋。试问，考虑地震作用组合，根据截面和配筋，该连梁所能承受的最大剪力设计值（kN）与下列何项数值最为接近？（ ）",[549,550,551,553],{"key":20,"text":267,"correct":22},{"key":24,"text":307,"correct":26},{"key":28,"text":552,"correct":22},"560",{"key":31,"text":554,"correct":22},"640",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":20,"analysis":33},928700,"某钢筋混凝土框架结构多层办公楼局部平面布置如图所示（均为办公室），梁、板、柱混凝土强度等级均为C30，梁、柱纵向钢筋为HRB400钢筋，楼板纵向钢筋及梁、柱箍筋为HRB335钢筋。 假设，雨篷梁KL1与柱刚接，试问，在雨篷荷载作用下，梁KL1的扭矩图与下列何项图示较为接近？（ ）",[559,560,561,562],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":28,"analysis":33},928701,"某钢筋混凝土框架结构多层办公楼局部平面布置如图所示（均为办公室），梁、板、柱混凝土强度等级均为C30，梁、柱纵向钢筋为HRB400钢筋，楼板纵向钢筋及梁、柱箍筋为HRB335钢筋。",[567,568,570,572],{"key":20,"text":33,"correct":22},{"key":24,"text":569,"correct":22},"假设，KL1梁端截面的剪力设计值V=160kN，扭矩设计值T=36kN·m，截面受扭塑性抵抗距Wt=2.475×107mm3，受扭的纵向普通钢筋与箍筋的配筋强度比ζ=1.0，混凝土受扭承载力降低系数βt=1.0，梁截面尺寸及配筋形式如图2-13所示。试问，以下何项箍筋配置与计算所需要的箍筋最为接近？（ ）",{"key":28,"text":571,"correct":26},"提示：纵筋的混凝土保护层厚度取30mm，as=40mm。",{"key":31,"text":33,"correct":22},[574,577,580,583,586,589],{"id":15,"name":575,"category":7,"favorite":576},"领导干部任职前廉政法规知识测试题",92,{"id":578,"name":579,"category":7,"favorite":15},595,"建筑结构与设备",{"id":581,"name":582,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":584,"name":585,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":587,"name":588,"category":7,"favorite":8},534,"BIM工程师",{"id":590,"name":588,"category":7,"favorite":8},535]