[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":585},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,25,50,1330,[13,34,42,54,66,78,88,96,104,112,124,136,148,160,172,184,194,206,218,230,242,250,262,274,286,298,310,322,334,346,358,370,382,394,406,418,430,440,448,460,472,482,494,506,513,525,537,549,561,573],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},929753,1,"单选题","某地上38层的现浇钢筋混凝土框架一核心筒办公楼，如图所示，房屋高度为155.4m，该建筑地上第1层至地上第4层的层高均为5.1m，第24层的层高6m，其余楼层的层高均为3.9m。抗震设防烈度7度，设计基本地震加速度0.10g，设计地震分组第一组，建筑场地类别为Ⅱ类，抗震设防类别为丙类，安全等级二级。 假定，核心筒剪力墙Q2第30层墙体及两侧边缘构件配筋如图6-6所示，剪力墙考虑地震作用组合的轴压力设计值N为3800kN。试问，剪力墙水平施工缝处抗滑移承载力设计值V（kN），与下列何项数值最为接近？（ ）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","3900",false,{"key":24,"text":25,"correct":22},"B","4500",{"key":27,"text":28,"correct":29},"C","4900",true,{"key":31,"text":32,"correct":22},"D","5500","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},929754,"某地上38层的现浇钢筋混凝土框架一核心筒办公楼，如图所示，房屋高度为155.4m，该建筑地上第1层至地上第4层的层高均为5.1m，第24层的层高6m，其余楼层的层高均为3.9m。抗震设防烈度7度，设计基本地震加速度0.10g，设计地震分组第一组，建筑场地类别为Ⅱ类，抗震设防类别为丙类，安全等级二级。",[38,39,40,41],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":27,"analysis":33},929755,"某底层带托柱转换层的钢筋混凝土框架—筒体结构办公楼，地下1层，地上25层，地下1层层高6.0m，地上1层至2层的层高均为4.5m，其余各层层高均为3.3m，房屋高度为85.2m，转换层位于地上2层，见图6-20所示。抗震设防烈度为7度，设计基本地震加速度为0.10g，设计分组为第一组，丙类建筑，Ⅲ类场地，混凝土强度等级：地上2层及以下均为C50，地上3层至5层为C40，其余各层均为C35。 假定，地上第2层转换梁的抗震等级为一级，某转换梁截面尺寸为700mm×1400mm，经计算求得梁端截面弯矩标准值（kN·m）如下：恒载Mgk=1304；活载（按等效均布荷载计）Mqk=169；风载Mwk=135；水平地震作用MEhk=300。试问，在进行梁端截面设计时，梁端考虑水平地震作用组合时的弯矩设计值M（kN·m）与下列何项数值最为接近？（ ）",[46,48,50,52],{"key":20,"text":47,"correct":22},"2100",{"key":24,"text":49,"correct":22},"2200",{"key":27,"text":51,"correct":29},"2350",{"key":31,"text":53,"correct":22},"2450",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":33},929756,"某底层带托柱转换层的钢筋混凝土框架—筒体结构办公楼，地下1层，地上25层，地下1层层高6.0m，地上1层至2层的层高均为4.5m，其余各层层高均为3.3m，房屋高度为85.2m，转换层位于地上2层，见图6-20所示。抗震设防烈度为7度，设计基本地震加速度为0.10g，设计分组为第一组，丙类建筑，Ⅲ类场地，混凝土强度等级：地上2层及以下均为C50，地上3层至5层为C40，其余各层均为C35。 假定，某转换柱的抗震等级为一级，其截面尺寸为900mm×900mm，混凝土强度等级为C50（fc=23.1N\u002Fmm2，ft=1.89N\u002Fmm2），纵筋和箍筋分别采用HRB400（fy=360N\u002Fmm2）和HRB335（fyv=300N\u002Fmm2），箍筋形式为井字复合箍，柱考虑地震作用效应组合的轴压力设计值为N=9350kN。试问，关于该转换柱加密区箍筋的体积配箍率ρV（％），最小取下列何项数值时才能满足规范、规程规定的最低要求？（ ）",[58,60,62,64],{"key":20,"text":59,"correct":29},"1.50",{"key":24,"text":61,"correct":22},"1.20",{"key":27,"text":63,"correct":22},"0.90",{"key":31,"text":65,"correct":22},"0.80",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":20,"analysis":33},929757,"某底层带托柱转换层的钢筋混凝土框架—筒体结构办公楼，地下1层，地上25层，地下1层层高6.0m，地上1层至2层的层高均为4.5m，其余各层层高均为3.3m，房屋高度为85.2m，转换层位于地上2层，见图6-20所示。抗震设防烈度为7度，设计基本地震加速度为0.10g，设计分组为第一组，丙类建筑，Ⅲ类场地，混凝土强度等级：地上2层及以下均为C50，地上3层至5层为C40，其余各层均为C35。 地上第2层某转换柱KZZ，如图23（z）所示，假定该柱的抗震等级为一级，柱上端和下端考虑地震作用组合的弯矩组合值分别为580kN·m、450kN·m，柱下端节点A左右梁端相应的同向组合弯矩设计值之和∑MB=1100kN·m。假设，转换柱KZZ在节点A处按弹性分析的上、下柱端弯矩相等。试问，在进行柱截面设计时，该柱上端和下端考虑地震作用组合的弯矩设计值Mt、Mb（kN·m）与下列何项数值最为接近？（ ）",[70,72,74,76],{"key":20,"text":71,"correct":29},"870、770",{"key":24,"text":73,"correct":22},"870、675",{"key":27,"text":75,"correct":22},"810、770",{"key":31,"text":77,"correct":22},"810、675",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},929759,"某底层带托柱转换层的钢筋混凝土框架—筒体结构办公楼，地下1层，地上25层，地下1层层高6.0m，地上1层至2层的层高均为4.5m，其余各层层高均为3.3m，房屋高度为85.2m，转换层位于地上2层，见图6-20所示。抗震设防烈度为7度，设计基本地震加速度为0.10g，设计分组为第一组，丙类建筑，Ⅲ类场地，混凝土强度等级：地上2层及以下均为C50，地上3层至5层为C40，其余各层均为C35。",[82,83,85,87],{"key":20,"text":33,"correct":22},{"key":24,"text":84,"correct":29},"假定，地面以上第2层（转换层）核心筒的抗震等级为二级，核心筒中某连梁截面尺寸为400mm×1200mm，净跨ln=1200mm，如图6-22所示。连梁的混凝土强度等级为C50（fc＝23.1N\u002Fmm2，ft=1.89N\u002Fmm2），连梁梁端有地震作用组合的最不利组合弯矩设计值（同为顺时针方向）如下：左端MlB=815kN·m；右端MrB=-812kN·m；梁端有地震作用组合的剪力Vb=1360kN。在重力荷载代表值作用下，按简支梁计算的梁端剪力设计值为VGb=54kN，连梁中设置交叉暗撑，暗撑纵筋采用HRB400（fy=360N\u002Fmm2）级钢筋，暗撑与水平线夹角为40o。试问，每根暗撑纵筋的截面积As（mm2）与下列何项的配筋面积最为接近？（ ）",{"key":27,"text":86,"correct":22},"提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）计算。",{"key":31,"text":33,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":27,"analysis":33},929760,"在第③轴底层落地剪力墙处，由不落地剪力墙传来按刚性楼板计算的框支层楼板组合的剪力设计值为3000kN（未经调整）。②～⑦轴处楼板无洞口，宽度15400mm。假定剪力沿③轴墙均布，穿过③轴墙的梁纵筋面积As1=10000mm2，穿墙楼板配筋宽度10800mm（不包括梁宽）。试问，③轴右侧楼板的最小厚度tf（mm）及穿过墙的楼板双层配筋中每层配筋的最小值为下列何项时，才能满足规范、规程的最低抗震要求？（ ） 提示：①按《建筑抗震设计规范》（GB 50011—2010）作答。②框支层楼板按构造配筋时满足楼板竖向承载力和水平平面内抗弯要求。",[92,93,94,95],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":31,"analysis":33},929761,"假定，第③轴底层墙肢A的抗震等级为一级，墙底截面见图27，墙厚度400mm，墙长hW=6400mm，hW0=6000mm，AW\u002FA=0.7，剪跨比=1.2，考虑地震作用组合的剪力计算值VW=4100kN，对应的轴向压力设计值N=19000kN，已知竖向分布筋为构造配置。试问，该截面竖向及水平向分布筋至少应按下列何项配置，才能满足规范、规程的抗震要求？（ ） 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。",[100,101,102,103],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":20,"analysis":33},929762,"第四层某剪力墙边缘构件如图6-32所示，阴影部分为纵向钢筋配筋范围，纵筋混凝土保护层厚度为20mm。已知剪力墙轴压比>0.3。试问，该边缘构件阴影部分的纵筋及箍筋为下列何项选项时，才能满足规范、规程的最低抗震构造要求？（ ） 提示：①按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。②箍筋体积配箍率计算时，扣除重叠部分箍筋。",[108,109,110,111],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":31,"analysis":33},929763,"假定，该建筑物使用需要，转换层设置在3层，房屋总高度不变，一至三层层高为4m，上部21层层高均为3m，第四层某剪力墙的边缘构件仍如图28所示。试问，该边缘构件纵向钢筋最小构造配箍率ρsv（％）及配箍特征值最小值λv取下列何项数值时，才能满足规范、规程的最低抗震构造要求？（ ） 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。（ ）",[116,118,120,122],{"key":20,"text":117,"correct":22},"1.2；0.2",{"key":24,"text":119,"correct":22},"1.4；0.2",{"key":27,"text":121,"correct":22},"1.2；0.24",{"key":31,"text":123,"correct":29},"1.4；0.24",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":24,"analysis":33},929764,"有一位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地上10层，高40m的钢筋混凝土框架结构。剖面和平面如图6-41所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共13000kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共14050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为1.0s。 该楼的结构布置、侧向刚度及质量等均对称、规则、均匀、属规则结构，则该楼总竖向地震作用标准值为（ ）kN。",[128,130,132,134],{"key":20,"text":129,"correct":22},"21000",{"key":24,"text":131,"correct":29},"22000",{"key":27,"text":133,"correct":22},"23000",{"key":31,"text":135,"correct":22},"24000",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":20,"analysis":33},929765,"有一位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地上10层，高40m的钢筋混凝土框架结构。剖面和平面如图6-41所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共13000kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共14050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为1.0s。 底层和顶层竖向地震作用标准值分别为（ ）kN。",[140,142,144,146],{"key":20,"text":141,"correct":29},"398.5；3985",{"key":24,"text":143,"correct":22},"498.5；4985",{"key":27,"text":145,"correct":22},"598.5；5985",{"key":31,"text":147,"correct":22},"698.5；6985",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":31,"analysis":33},929766,"有一位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地上10层，高40m的钢筋混凝土框架结构。剖面和平面如图6-41所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共13000kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共14050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为1.0s。 底层中柱A的竖向地震轴向力标准值NEvk为（ ）kN。",[152,154,156,158],{"key":20,"text":153,"correct":22},"800",{"key":24,"text":155,"correct":22},"900",{"key":27,"text":157,"correct":22},"1000",{"key":31,"text":159,"correct":29},"1100",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":33},929767,"一商店的单层平面框架，如图所示。 由屋顶永久荷载标准值产生的D点柱顶弯矩标准值MDgk=50kN·m，由屋顶均布活荷载标准值产生的弯矩标准值MDqk=30kN·m，由此可算得上述两种情况D点的弯矩设计值MD=（ ）kN·m。",[164,166,168,170],{"key":20,"text":165,"correct":22},"130",{"key":24,"text":167,"correct":29},"102",{"key":27,"text":169,"correct":22},"96.9",{"key":31,"text":171,"correct":22},"95",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":27,"analysis":33},929768,"一商店的单层平面框架，如图所示。 在（1）的单层平面框架中，除由竖向均布荷载gk及qk产生的D点弯矩标准值MDgk=50kN·m及MDqk=30kN·m外，现尚需计及如图6-33所示由风荷载产生的D点弯距标准值MDwk=25kN·m，由此算得D点在上述三种工况组合后的弯矩设计值MD=（ ）kN·m。 提示：计算时对效应的组合不采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则。",[176,178,180,182],{"key":20,"text":177,"correct":22},"117.9",{"key":24,"text":179,"correct":22},"123.0",{"key":27,"text":181,"correct":29},"124.4",{"key":31,"text":183,"correct":22},"140.0",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":20,"analysis":33},929769,"一商店的单层平面框架，如图所示。 在计算时对效应的组合采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则，则由此算得D点在上述两种工况组合后的弯矩设计值MD=（ ）kN·m。",[188,190,191,193],{"key":20,"text":189,"correct":29},"129.3",{"key":24,"text":181,"correct":22},{"key":27,"text":192,"correct":22},"123",{"key":31,"text":177,"correct":22},{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":20,"analysis":33},929770,"一商店的单层平面框架，如图所示。 在（1）的单层框架中，由屋顶永久荷载标准值产生的柱顶D点轴向压力标准值NDgk=100kN，屋顶均布活荷载标准值产生的轴向压力标准值NDqk=60kN，风荷载标准值产生的轴向压力标准值NDwk=30kN（见图6-40），由此算得在上述三种工况组合后的柱顶D点轴向压力设计值ND=（ ）kN。",[198,200,202,204],{"key":20,"text":199,"correct":29},"229.2",{"key":24,"text":201,"correct":22},"220.8",{"key":27,"text":203,"correct":22},"210.5",{"key":31,"text":205,"correct":22},"200.3",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":31,"analysis":33},929771,"下列关于高层混凝土结构作用效应计算时剪力墙连梁刚度折减的观点，哪一项不符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）的要求？（ ）",[210,212,214,216],{"key":20,"text":211,"correct":22},"结构进行风荷载作用下的内力计算时，不宜考虑剪力墙连梁刚度折减",{"key":24,"text":213,"correct":22},"第3性能水准的结构采用等效弹性方法进行罕遇地震作用下竖向构件的内力计算时，剪力墙连梁刚度可折减，折减系数不宜小于0.3",{"key":27,"text":215,"correct":22},"结构进行多遇地震作用下的内力计算时，可对剪力墙连梁刚度予以折减，折减系数不宜小于0.5",{"key":31,"text":217,"correct":29},"结构进行多遇地震作用下的内力计算时，连梁刚度折减系数与抗震设防烈度无关",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":27,"analysis":33},929772,"下列关于高层混凝土结构地下室及基础的设计观点，哪一项相对准确？（ ）",[222,224,226,228],{"key":20,"text":223,"correct":22},"基础埋置深度，无论采用天然地基还是桩基，都不应小于房屋高度的1／18",{"key":24,"text":225,"correct":22},"上部结构的嵌固部位尽量设在地下室顶板以下或基础顶，减小底部加强区高度，提高结构设计的经济性",{"key":27,"text":227,"correct":29},"建于8度、Ⅲ类场地的高层建筑，宜采用刚度好的基础",{"key":31,"text":229,"correct":22},"高层建筑应调整基础尺寸，基础底面不应出现零应力区",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":24,"analysis":33},929773,"某高层现浇钢筋混凝土框架结构普通办公楼，结构设计使用年限50年，抗震等级一级，安全等级二级。其中五层某框架梁局部平面如图6-1所示。进行梁截面设计时，需考虑重力荷载、水平地震作用效应组合。 已知，该梁截面A处由重力荷载、水平地震作用产生的负弯矩标准值分别为： 恒荷载：MGk=-500kN·m； 活荷载：MQk=-100kN·m； 水平地震作用：MEhk=-260kN·m； 试问，进行截面A梁顶配筋设计时，起控制作用的梁端负弯矩设计值（kN·m），与下列何项数值最为接近？（ ） 提示：活荷载按等效均布计算，不考虑梁楼面活荷载标准值折减，重力荷载效应已考虑支座负弯矩调幅，不考虑风荷载组合。",[234,236,238,240],{"key":20,"text":235,"correct":22},"-740",{"key":24,"text":237,"correct":29},"-780",{"key":27,"text":239,"correct":22},"-1000",{"key":31,"text":241,"correct":22},"-1060",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":20,"analysis":33},929774,"某高层现浇钢筋混凝土框架结构普通办公楼，结构设计使用年限50年，抗震等级一级，安全等级二级。其中五层某框架梁局部平面如图6-1所示。进行梁截面设计时，需考虑重力荷载、水平地震作用效应组合。",[246,247,248,249],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":24,"analysis":33},929775,"某钢筋混凝土底部加强部位剪力墙，抗震设防烈度7度，抗震等级一级，平、立面如图6-2所示，混凝土强度等级C30（fc=14.3N／mm2，Ec=3.0×104N／mm2）。 假定，墙肢Qz1底部考虑地震作用组合的轴力设计值N=4800kN，重力荷载代表值作用下墙肢承受的轴压力设计值NGE=3900kN，bf=bw。试问，满足Qz1轴压比要求的最小墙厚bw（mm），与下列何项数值最为接近？（ ）",[254,256,258,260],{"key":20,"text":255,"correct":22},"300",{"key":24,"text":257,"correct":29},"350",{"key":27,"text":259,"correct":22},"400",{"key":31,"text":261,"correct":22},"450",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},929776,"某高层建筑裙楼商场内人行天桥，采用钢一混凝土组合结构，如图6-3所示，天桥跨度28m。假定，天桥竖向自振频率为fn=3.5Hz，结构阻尼比β=0.02，单位面积有效重量，试问，满足楼盖舒适度要求的最小天桥宽度B（m），与下列何项数值最为接近？（ ） 提示：①按《高层建筑混凝土结构技术规程》JGJ3—2010作答； ②接近楼盖自振频率时，人行走产生的作用力Fp=0.12kN。",[266,268,270,272],{"key":20,"text":267,"correct":22},"1.80",{"key":24,"text":269,"correct":29},"2.60",{"key":27,"text":271,"correct":22},"3.30",{"key":31,"text":273,"correct":22},"5.00",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},929777,"某环形截面钢筋混凝土烟囱，如图所示，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组第一组，场地类别Ⅱ类，基本风压w0=0.40kN／m2。烟囱基础顶面以上总重力荷载代表值为15000kN，烟囱基本自振周期为T1=2.5s。 .已知，烟囱底部（基础顶面处）由风荷载标准值产生的弯矩M=11000kN·m，由水平地震作用标准值产生的弯矩M=18000kN·m，由地震作用、风荷载、日照和基础倾斜引起的附加弯矩M=1800kN·m。试问，烟囱底部截面进行抗震极限承载能力设计时，烟囱抗弯承载力设计值最小值Rd（kN·m），与下列何项数值最为接近？（ ）",[278,280,282,284],{"key":20,"text":279,"correct":22},"28200",{"key":24,"text":281,"correct":29},"25500",{"key":27,"text":283,"correct":22},"25000",{"key":31,"text":285,"correct":22},"22500",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":31,"analysis":33},929778,"某环形截面钢筋混凝土烟囱，如图所示，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组第一组，场地类别Ⅱ类，基本风压w0=0.40kN／m2。烟囱基础顶面以上总重力荷载代表值为15000kN，烟囱基本自振周期为T1=2.5s。 烟囱底部（基础顶面处）截面筒壁竖向配筋设计时，需要考虑地震作用并按大、小偏心受压包络设计，已知，小偏心受压时重力荷载代表值的轴压力对烟囱承载能力不利，大偏心受压时重力荷载代表值的轴压力对烟囱承载能力有利。假定，小偏心受压时轴压力设计值为N1（kN），大偏心受压时轴压力设计值为N2（kN）。试问，N1、N2与下列何项数值最为接近？（ ）",[290,292,294,296],{"key":20,"text":291,"correct":22},"18000、15660",{"key":24,"text":293,"correct":22},"20340、15660",{"key":27,"text":295,"correct":22},"18900、12660",{"key":31,"text":297,"correct":29},"19500、13500",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},929779,"下列关于高层混凝土剪力墙结构抗震设计的观点，哪一项不符合《高层建筑混凝土结构技术规程》JGJ 3—2010的要求？（ ）",[302,304,306,308],{"key":20,"text":303,"correct":29},"剪力墙墙肢宜尽量减小轴压比，以提高剪力墙的抗剪承载力",{"key":24,"text":305,"correct":22},"楼面梁与剪力墙平面外相交时，对梁截面高度与墙肢厚度之比小于2的楼面梁，可通过支座弯矩调幅实现梁端半刚接设计，减少剪力墙平面外弯矩",{"key":27,"text":307,"correct":22},"进行墙体稳定验算时，对翼缘截面高度小于截面厚度2倍的剪力墙，考虑翼墙的作用，但应满足整体稳定的要求",{"key":31,"text":309,"correct":22},"剪力墙结构存在较多各肢截面高度与厚度之比大于4但不大于8的剪力墙时，只要墙肢厚度大于300mm，在规定的水平地震作用下，该部分较短剪力墙承担的底部倾覆力矩可大于结构底部总地震倾覆力矩的50%",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":31,"analysis":33},929780,"下列关于高层混凝土结构重力二阶效应的观点，哪一项相对准确？（ ）",[314,316,318,320],{"key":20,"text":315,"correct":22},"当结构满足规范要求的顶点位移和层问位移限值时，高度较低的结构重力二阶效应的影响较小",{"key":24,"text":317,"correct":22},"当结构在地震作用下的重力附加弯矩大于初始弯矩的10%时，应计入重力二阶效应的影响，风荷载作用时，可不计入",{"key":27,"text":319,"correct":22},"框架柱考虑多遇地震作用产生的重力二阶效应的内力时，尚应考虑《混凝土结构规范》GB50010—2010承载力计算时需要考虑的重力二阶效应",{"key":31,"text":321,"correct":29},"重力二阶效应影响的相对大小主要与结构的侧向刚度和自重有关，随着结构侧向刚度的降低，重力二阶效应的不利影响呈非线性关系急剧增长，结构侧向刚度满足水平位移限值要求，有可能不满足结构的整体稳定要求",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":31,"analysis":33},929781,"某拟建现浇钢筋混凝土高层办公楼，抗震设防烈度为8度（0.2g），丙类建筑，Ⅱ类建筑场地，平、剖面如图6-8所示。地上18层，地下2层，地下室顶板&plusmn;0.000处可作为上部结构嵌固部位。房屋高度受限，最高不超过60.3m，室内结构构件（梁或板）底净高不小于2.6m，建筑面层厚50mm。方案比较时，假定，&plusmn;0.000以上标准层平面构件截面满足要求，如果从结构体系、净高要求及楼层结构混凝土用量考虑，下列四种方案中哪种方案相对合理？（ ）",[326,328,330,332],{"key":20,"text":327,"correct":22},"方案一：室内无柱，外框梁L1（500&times;800），室内无梁，400厚混凝土平板楼盖",{"key":24,"text":329,"correct":22},"方案二：室内 A、B处设柱，外框梁L1（400&times;700），梁板结构，沿柱中轴线设框架梁L2（400&times;700），无次梁，300厚混凝土楼板",{"key":27,"text":331,"correct":22},"方案三：室内B处设柱，外框梁L1（400&times;700），梁板结构，沿柱中轴线设框架梁L2（800&times;450）；无次梁，200厚混凝土板楼盖",{"key":31,"text":333,"correct":29},"方案四：室内B处设柱，外框梁L1，沿柱中轴线设框架梁L2，L1、L2同方案三，梁板结构，次梁L3（200&times;400），100厚混凝土楼板",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":27,"analysis":33},929782,"某16层现浇钢筋混凝土框架-剪力墙结构办公楼，房屋高度为64.3m，如图6-9所示，楼板无削弱。抗震设防烈度为8度，丙类建筑，Ⅱ类建筑场地。假定，方案比较时，发现X、Y方向每向可以减少两片剪力墙（减墙后结构承载力及刚度满足规范要求）。试问，如果仅从结构布置合理性考虑，下列四种减墙方案中哪种方案相对合理？（ ）",[338,340,342,344],{"key":20,"text":339,"correct":22},"X向：W1；Y向：W5",{"key":24,"text":341,"correct":22},"X向：W2；Y向：W6",{"key":27,"text":343,"correct":29},"X向：W3；Y向：W4",{"key":31,"text":345,"correct":22},"X向：W2；Y向：W7",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":33},929783,"某20层现浇钢筋混凝土框架-剪力墙结构办公楼，某层层高3.5m，楼板自外围竖向构件外挑，多遇水平地震标准值作用下，楼层平面位移如图6-10所示。该层层间位移采用各振型位移的CQC组合值，见表6-4；整体分析时采用刚性楼盖假定，在振型组合后的楼层地震剪力换算的水平力作用下楼层层间位移，见表6-5。试问，该楼层扭转位移比控制值验算时，其扭转位移比应取下列哪组数值？（ ） △uA——同一侧楼层角点（挑板）处最大层间位移； △uB——同一侧楼层角点处竖向构件最大层间位移； △uC——同一侧楼层角点（挑板）处最小层间位移； △uD——同一侧楼层角点处竖向构件最小层间位移； △uE——楼层所有竖向构件平均层间位移。",[350,352,354,356],{"key":20,"text":351,"correct":22},"1.25",{"key":24,"text":353,"correct":29},"1.28",{"key":27,"text":355,"correct":22},"1.31",{"key":31,"text":357,"correct":22},"1.36",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},929784,"某平面不规则的现浇钢筋混凝土高层结构，整体分析时采用刚性楼盖假定计算，结构自振周期见表6-6。试问，对结构扭转不规则判断时，扭转为主的第一自振周期Tt与平动为主的第一自振周期T1之比值最接近下列何项数值？（ ）",[362,364,366,368],{"key":20,"text":363,"correct":22},"0.71",{"key":24,"text":365,"correct":29},"0.82",{"key":27,"text":367,"correct":22},"0.87",{"key":31,"text":369,"correct":22},"0.93",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":33},929785,"某普通办公楼，采用现浇钢筋混凝土框架—核心筒结构，房屋高度116.3m，地上31层，地下2层，3层设转换层，采用桁架转换构件，平、剖面如图6-15所示。抗震设防烈度为7度（0.1g），丙类建筑，设计地震分组第二组，Ⅱ类建筑场地，地下室顶板±0.000处作为上部结构嵌固部位。 该结构需控制罕遇地震作用下薄弱层的层间位移。假定，主体结构采用等效弹性方法进行罕遇地震作用下弹塑性计算分析时，结构总体上刚刚进入屈服阶段。电算程序需输入的计算参数分别为：连梁刚度折减系数S1；结构阻尼比S2；特征周期值S3。试问，下.列各组参数中（依次为S1、S2、S3），其中哪一组相对准确？（ ）",[374,376,378,380],{"key":20,"text":375,"correct":29},"0.4、0.06、0.45",{"key":24,"text":377,"correct":22},"0.4、0.06、0.40",{"key":27,"text":379,"correct":22},"0.5、0.05、0.45",{"key":31,"text":381,"correct":22},"0.2、0.06、0.40",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":33},929786,"某普通办公楼，采用现浇钢筋混凝土框架—核心筒结构，房屋高度116.3m，地上31层，地下2层，3层设转换层，采用桁架转换构件，平、剖面如图6-15所示。抗震设防烈度为7度（0.1g），丙类建筑，设计地震分组第二组，Ⅱ类建筑场地，地下室顶板±0.000处作为上部结构嵌固部位。 .假定，振型分解反应谱法求得的2～4层的水平地震剪力标准值（Vi）及相应层间位移值（△i）见表6-9。在P=1000kN水平力的作用下，按图6-16模型计算的位移分别为：△1=7.8mm；△2=6.2mm。试问，进行结构竖向规则性判断时，宜取下列哪种方法及结果作为结构竖向不规则的判断依据？（ ） 提示：3层转换层按整层计。",[386,388,390,392],{"key":20,"text":387,"correct":22},"等效剪切刚度比验算方法，侧向刚度比不满足要求",{"key":24,"text":389,"correct":29},"楼层侧向刚度比验算方法，侧向刚度比不满足规范要求",{"key":27,"text":391,"correct":22},"考虑层高修正的楼层侧向刚度比验算方法，侧向刚度比不满足规范要求",{"key":31,"text":393,"correct":22},"等效侧向刚度比验算方法，等效刚度比不满足规范要求",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":24,"analysis":33},929787,"某70层办公楼，平、立面如图所示，采用钢筋混凝土筒中筒结构，抗震设防烈度为7度，丙类建筑，Ⅱ类建筑场地。房屋高度地面以上为250m，质量和刚度沿竖向分布均匀。已知小震弹性计算时，振型分解反应谱法求得的底部地震剪力为16000kN，最大层间位移角出现在k层，θk=1／600。 该结构性能化设计时，需要进行弹塑性动力时程分析补充计算，现有7条实际地震记录加速度时程曲线P1～P7和4组人工模拟加速度时程曲线RP1～RP4，假定，任意7条实际记录地震波及人工波的平均地震影响系数曲线与振型分解反应谱法所采用的地震影响系数曲线在统计意义上相符，各条时程曲线由同一软件计算所得的结构底部剪力见表6-10。试问，进行弹塑性动力时程分析时，选用下列哪一组地震波最为合理？（ ）",[398,400,402,404],{"key":20,"text":399,"correct":22},"P1、P2、P4、P5、RP1、RP2、RP4",{"key":24,"text":401,"correct":29},"P1、P2、P4、P5、P7、RP1、RP4",{"key":27,"text":403,"correct":22},"P1、P2、P4、P5、P7、KP2、RP4",{"key":31,"text":405,"correct":22},"P1、P2、P3、P4、P5、RP1、RP4",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":33},929788,"某70层办公楼，平、立面如图所示，采用钢筋混凝土筒中筒结构，抗震设防烈度为7度，丙类建筑，Ⅱ类建筑场地。房屋高度地面以上为250m，质量和刚度沿竖向分布均匀。已知小震弹性计算时，振型分解反应谱法求得的底部地震剪力为16000kN，最大层间位移角出现在k层，θk=1／600。 假定，正确选用的7条时程曲线分别为：AP1～AP7，由同一软件计算所得的第k层结构的层间位移角（同一层）见表6-11。试问，估算的大震下该层的弹塑性层间位移角参考值最接近下列何项数值？（ ） 提示：按《建筑抗震设计规范》GB 50011—2010作答。",[410,412,414,416],{"key":20,"text":411,"correct":22},"1／90",{"key":24,"text":413,"correct":29},"1／100",{"key":27,"text":415,"correct":22},"1／125",{"key":31,"text":417,"correct":22},"1／145",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":27,"analysis":33},929789,"以下关于高层建筑混凝土结构设计与施工的4种观点： Ⅰ.分段搭设的悬挑脚手架，每段高度不得超过25m； Ⅱ.大体积混凝土浇筑体的里表温差不宜大于25℃，混凝土浇筑表面与大气温差不宜大于20℃； Ⅲ.混合结构核心筒应先于钢框架或型钢混凝土框架施工，高差宜控制在4～8层，并应满足施工工序的穿插要求； Ⅳ.常温施工时，柱、墙体拆模混凝土强度不应低于1.2MPa。 试问，针对上述观点是否符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）相关要求的判断，下列何项正确？（ ）",[422,424,426,428],{"key":20,"text":423,"correct":22},"Ⅰ、Ⅱ符合，Ⅲ、Ⅳ不符合",{"key":24,"text":425,"correct":22},"Ⅰ、Ⅲ符合，Ⅱ、Ⅳ不符合",{"key":27,"text":427,"correct":29},"Ⅱ、Ⅲ符合，Ⅰ、Ⅳ不符合",{"key":31,"text":429,"correct":22},"Ⅲ、Ⅳ符合，Ⅰ、Ⅱ不符合",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},929790,"某高层现浇钢筋混凝土框架结构，其抗震等级为二级，框架梁局部配筋如图6-23所示，梁、柱混凝土强度等级C40（fc=19.1N\u002Fmm2），梁纵筋为HRB400（fy=360N\u002Fmm2），箍筋HRB335（fy=300N\u002Fmm2），as=60mm。",[434,435,437,439],{"key":20,"text":33,"correct":22},{"key":24,"text":436,"correct":29},"关于梁端A—A剖面处纵向钢筋的配置，如果仅从框架抗震构造措施方面考虑，下列何项配筋相对合理？（ ）",{"key":27,"text":438,"correct":22},"提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。",{"key":31,"text":33,"correct":22},{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":27,"analysis":33},929791,"某高层现浇钢筋混凝土框架结构，其抗震等级为二级，框架梁局部配筋如图6-23所示，梁、柱混凝土强度等级C40（fc=19.1N\u002Fmm2），梁纵筋为HRB400（fy=360N\u002Fmm2），箍筋HRB335（fy=300N\u002Fmm2），as=60mm。 假定，该建筑物较高，其所在建筑场地类别为Ⅳ类，计算表明该结构角柱为小偏心受拉，其计算纵筋面积为3600mm2，采用HRB400级钢筋（fy=360N\u002Fmm2），配置如图6-24所示。试问，该柱纵向钢筋最小取下列何项配筋时，才能满足规范、规程的最低要求？（ ）",[444,445,446,447],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":20,"analysis":33},929792,"根据《建筑抗震设计规范》（GB 50011—2010）及《高层建筑混凝土结构技术规程》（JGJ 3—2010），下列关于高层建筑混凝土结构抗震变形验算（弹性工作状态）的观点，哪一种相对准确？（ ）",[452,454,456,458],{"key":20,"text":453,"correct":29},"结构楼层位移和层间位移控制值验算时，采用CQC的效应组合，位移计算时不考虑偶然偏心影响；扭转位移比计算时，不采用各振型位移的CQC组合计算，位移计算时考虑偶然偏心的影响",{"key":24,"text":455,"correct":22},"结构楼层位移和层间位移控制值验算以及扭转位移比计算时，均采用CQC的效应组合，位移计算时，均考虑偶然偏心影响",{"key":27,"text":457,"correct":22},"结构楼层位移和层间位移控制值验算以及扭转位移比计算时，均采用CQC的效应组合，位移计算时，均不考虑偶然偏心影响",{"key":31,"text":459,"correct":22},"结构楼层位移和层间位移控制值验算时，采用CQC的效应组合，位移计算时考虑偶然偏心影响；扭转位移比计算时，不采用CQC组合计算，位移计算时不考虑偶然偏心的影响",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":27,"analysis":33},929793,"下列关于高层混凝土结构抗震性能化设计的观点，哪一项不符合《建筑抗震设计规范》（GB 50011—2010）的要求？（ ）",[464,466,468,470],{"key":20,"text":465,"correct":22},"选定性能目标应不低于“小震不坏，中震可修和大震不倒”的性能设计目标",{"key":24,"text":467,"correct":22},"结构构件承载力按性能3要求进行中震复核时，承载力按标准值复核，不计入作用分项系数、承载力抗震调整系数和内力调整系数，材料强度取标准值",{"key":27,"text":469,"correct":29},"结构构件地震残余变形按性能3要求进行中震复核时，整个结构中变形最大部位的竖向构件，其弹塑性位移角限值，可取常规设计时弹性层间位移角限值",{"key":31,"text":471,"correct":22},"结构构件抗震构造按性能3要求确定抗震等级时，当构件承载力高于多遇地震提高一度的要求时，构造所对应的抗震等级可降低一度，且不低于6度采用，不包括影响混凝土构件正截面承载力的纵向受力钢筋的构造要求",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":20,"analysis":33},929794,"某环形截面钢筋混凝土烟囱，如图6-26所示，烟囱基础顶面以上总重力荷载代表值为18000kN，烟囱基本自振周期T1=2.5s",[476,477,479,481],{"key":20,"text":33,"correct":29},{"key":24,"text":478,"correct":22},"如果烟囱建于非地震区，基本风压w0=0.5kN\u002Fm2，地面粗糙度为B类。试问，烟囱承载能力极限状态设计时，风荷载按下列何项考虑？（ ）",{"key":27,"text":480,"correct":22},"提示：假定烟囱第2及以上振型，不出现跨临界的强风共振。",{"key":31,"text":33,"correct":22},{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":27,"analysis":33},929795,"某大底盘单塔楼高层建筑，主楼为钢筋混凝土框架—核心筒，裙房为混凝土框架—剪力墙结构，主楼与裙楼连为整体，如图6-28所示。抗震设防烈度7度，建筑抗震设防类别为丙类，设计基本地震加速度为0.15g，场地Ⅲ类，采用桩筏形基础。 假定，该建筑物塔楼质心偏心距为e1，大底盘质心偏心距为e2，见图24。如果仅从抗震概念设计方面考虑，试问，偏心距（e1，e2；单位：m）选用下列哪一组数值时结构不规则程度相对最小？（ ）",[486,488,490,492],{"key":20,"text":487,"correct":22},"0.0；0.0",{"key":24,"text":489,"correct":22},"0.1；5.0",{"key":27,"text":491,"correct":29},"0.2；7.2",{"key":31,"text":493,"correct":22},"1.0；8.0",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":31,"analysis":33},929796,"某大底盘单塔楼高层建筑，主楼为钢筋混凝土框架—核心筒，裙房为混凝土框架—剪力墙结构，主楼与裙楼连为整体，如图6-28所示。抗震设防烈度7度，建筑抗震设防类别为丙类，设计基本地震加速度为0.15g，场地Ⅲ类，采用桩筏形基础。 裙房一榀横向框架距主楼18m，某一顶层中柱上、下端截面组合弯矩设计值分别为 320kN·m，350kN·m（同为顺时针方向）；剪力计算值为125kN，柱断面为500mm×500mm，Hn=5.2m，>2，混凝土强度等级C40。在不采用有利于提高轴压比限值的构造措施的条件下，试问，该柱截面设计时，轴压比限值[μn]及剪力设计值（kN）应取下列何组数值才能满足规范的要求？（ ） 提示：按《建筑抗震设计规范》（GB 50011—2010）作答；V=ηvc（Mcb+Mct）\u002FHn。",[498,500,502,504],{"key":20,"text":499,"correct":22},"0.90；125",{"key":24,"text":501,"correct":22},"0.75；170",{"key":27,"text":503,"correct":22},"0.85；155",{"key":31,"text":505,"correct":29},"0.75；155",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":508,"answer":24,"analysis":33},929797,[509,510,511,512],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":24,"analysis":33},929798,"某框架结构，抗震等级为一级，底层角柱如图6-30所示。考虑地震作用组合时按弹性分析未经调整的构件端部组合弯矩设计值为：柱：McA上=300kN·m，McA下=280kN·m（同为顺时针方向），柱底MB=320kN·m；梁：Mb=460kN·m。已知梁h0=560mm，a's=40mm，梁端顶面实配钢筋（HRB400级）面积As=2281mm2（计入梁受压筋和相关楼板钢筋影响）。试问该柱进行截面配筋设计时所采用的组合弯矩设计值（kN·m），与下列何项数值最为接近？（ ） 提示：按《建筑抗震设计规范》（GB 50011—2010）作答。",[517,519,521,523],{"key":20,"text":518,"correct":22},"780",{"key":24,"text":520,"correct":29},"600",{"key":27,"text":522,"correct":22},"545",{"key":31,"text":524,"correct":22},"365",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":27,"analysis":33},929799,"长矩形平面现浇钢筋混凝土框架—剪力墙高层结构，楼、屋盖抗震墙之间无大洞口，抗震设防烈度为8度时，下列关于剪力墙布置的几种说法，其中何项不够准确？（ ）",[529,531,533,535],{"key":20,"text":530,"correct":22},"结构两主轴方向均应布置剪力墙",{"key":24,"text":532,"correct":22},"楼、屋盖长宽比不大于3时，可不考虑楼盖平面内变形对楼层水平地震剪力分配的影响",{"key":27,"text":534,"correct":29},"两方向的剪力墙宜集中布置在结构单元的两尽端，增大整个结构的抗扭能力",{"key":31,"text":536,"correct":22},"剪力墙的布置宜使结构各主轴方向的侧向刚度接近",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":27,"analysis":33},929800,"一库房为6m间距的单跨门式刚架，如图6-33所示，该刚架的斜梁与水平线间的夹角为25°，斜梁上铺设槽钢檩条和压型钢板。檩条间距为1.5m，计算跨度为6m。该地区的基本雪压s0＝0.5kN\u002Fm2。由此可算得檩条上由屋面积雪荷载产生沿檩条跨度的线荷载标准值qs＝（ ）kN\u002Fm。",[541,543,545,547],{"key":20,"text":542,"correct":22},"0.68",{"key":24,"text":544,"correct":22},"0.75",{"key":27,"text":546,"correct":29},"0.85",{"key":31,"text":548,"correct":22},"0.94",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":31,"analysis":33},929801,"计算一大雨篷中间主钢梁的梁端弯矩设计值，如图6-34所示。该雨篷的主钢梁G1与型钢混凝土框架柱相连，柱距为9m，主钢梁悬挑长度为6m。主钢梁上铺设带金属边框构件的采光玻璃，其重量包括主钢梁在内为0.80kN\u002Fm2。钢梁面标高为5.0m。该建筑在10m高度处的基本风压w0＝0.70kN\u002Fm2，地面粗糙度为A类。现需计算在雨篷结构永久荷载和风的负风压（吸力）作用下主钢梁G1的梁端弯矩设计值MA＝（ ）kN·m。",[553,555,557,559],{"key":20,"text":554,"correct":22},"155.5",{"key":24,"text":556,"correct":22},"-120",{"key":27,"text":558,"correct":22},"-180",{"key":31,"text":560,"correct":29},"-242.4",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":24,"analysis":33},929802,"如图所示，在B类粗糙度场地上建一座高为125m的钢筋混凝土烟囱。100年一遇的风载标准值w0＝0.65kN\u002Fm2。烟囱自重的标准值GK＝18738.8kN，筒身的重心C距基础顶面H0＝37.7m。 烟囱的第一周期T1最接近于（ ）s。",[565,567,569,571],{"key":20,"text":566,"correct":22},"2.213",{"key":24,"text":568,"correct":29},"2.914",{"key":27,"text":570,"correct":22},"3.756",{"key":31,"text":572,"correct":22},"4.106",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":31,"analysis":33},929803,"如图所示，在B类粗糙度场地上建一座高为125m的钢筋混凝土烟囱。100年一遇的风载标准值w0＝0.65kN\u002Fm2。烟囱自重的标准值GK＝18738.8kN，筒身的重心C距基础顶面H0＝37.7m。 62.50m处该烟囱的风振系数βz最接近于（ ）。",[577,579,581,583],{"key":20,"text":578,"correct":22},"1.79",{"key":24,"text":580,"correct":22},"1.68",{"key":27,"text":582,"correct":22},"1.60",{"key":31,"text":584,"correct":29},"1.42",[586,589,592,595,598,601],{"id":15,"name":587,"category":7,"favorite":588},"领导干部任职前廉政法规知识测试题",92,{"id":590,"name":591,"category":7,"favorite":15},595,"建筑结构与设备",{"id":593,"name":594,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":596,"name":597,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":599,"name":600,"category":7,"favorite":8},534,"BIM工程师",{"id":602,"name":600,"category":7,"favorite":8},535]