[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":600},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,23,50,1330,[13,34,46,58,70,82,94,106,117,129,141,149,159,171,183,195,207,219,231,243,251,263,271,283,295,307,319,330,342,354,366,378,390,402,414,426,438,450,462,474,486,498,510,522,534,544,555,565,577,589],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},929652,1,"单选题","某16层现浇钢筋混凝土框架-剪力墙结构，房屋高度为64m，抗震设防烈度为7度，丙类建筑，场地类别Ⅱ类。在规定的水平力作用下，结构底层剪力墙部分承受的地震倾覆力矩为结构总地震倾覆力矩的92％。下列关于框架、剪力墙抗震等级的确定何项正确？（ ）[2012年真题]",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","框架三级.剪力墙三级",false,{"key":24,"text":25,"correct":22},"B","框架二级.剪力墙二级",{"key":27,"text":28,"correct":22},"C","框架三级.剪力墙二级",{"key":30,"text":31,"correct":32},"D","框架二级.剪力墙三级",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},929653,"某16层办公楼采用钢筋混凝土框架-剪力墙结构体系，层高均为4米，平面对称，结构布置均匀规则，质量和侧向刚度沿高度分布均匀，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第二组，建筑场地类别为Ⅲ类。考虑折减后的结构自振周期为 各楼层的重力荷载代表 结构的第一振型如图所示。采用振型分解反应谱法计算地震作用。[2012年真题] 提示： 3.假定，横向水平地震作用计算时，该结构前三个振型基底剪力标准值分别为 相邻振型的周期比小于0.85。试问，横向对应于水平地震作用标准值的结构底层总剪力 最接近下列何项数值？（ ） 提示：结构不进行扭转耦联计算且仅考虑前三个振型地震作用。",[38,40,42,44],{"key":20,"text":39,"correct":32},"13200",{"key":24,"text":41,"correct":22},"14200",{"key":27,"text":43,"correct":22},"14800",{"key":30,"text":45,"correct":22},"15100",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},929654,"某16层办公楼采用钢筋混凝土框架-剪力墙结构体系，层高均为4米，平面对称，结构布置均匀规则，质量和侧向刚度沿高度分布均匀，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第二组，建筑场地类别为Ⅲ类。考虑折减后的结构自振周期为 各楼层的重力荷载代表 结构的第一振型如图所示。采用振型分解反应谱法计算地震作用。[2012年真题] 提示： 2.假定，第一振型时地震影响系数为0.09，振型参与系数为1.5。试问，第一振型时的基底弯矩标准值(kN·m)最接近下列何项数值？（ ）",[50,52,54,56],{"key":20,"text":51,"correct":32},"685000",{"key":24,"text":53,"correct":22},"587000",{"key":27,"text":55,"correct":22},"485000",{"key":30,"text":57,"correct":22},"400000",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},929655,"某16层办公楼采用钢筋混凝土框架-剪力墙结构体系，层高均为4米，平面对称，结构布置均匀规则，质量和侧向刚度沿高度分布均匀，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第二组，建筑场地类别为Ⅲ类。考虑折减后的结构自振周期为 各楼层的重力荷载代表 结构的第一振型如图所示。采用振型分解反应谱法计算地震作用。[2012年真题] 提示： 1.试问，第一振型时的基底剪力标准值V10(kN)最接近下列何项数值？（ ）",[62,64,66,68],{"key":20,"text":63,"correct":22},"10000",{"key":24,"text":65,"correct":32},"13000",{"key":27,"text":67,"correct":22},"14000",{"key":30,"text":69,"correct":22},"15000",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},929656,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 5.假定，在规定的水平作用下，该结构底层框架部分承受的地震倾覆力矩为结构总地震倾覆力矩的60％，已知底层某框架柱截面为800mm×800mm，剪跨比大于2，混凝土强度等级C40（fn=19.1N\u002Fmm2），在不采用有利于提高轴压比限值的构造措施的条件下。试问，满足规范轴压比限值要求时，该柱考虑地震作用组合的轴压力设计值（kN）最大值，与下列何项数值最为接近？（ ） 提示：按《建筑抗震设计规范》（GB 50011—2010）作答。",[74,76,78,80],{"key":20,"text":75,"correct":32},"7950",{"key":24,"text":77,"correct":22},"8560",{"key":27,"text":79,"correct":22},"9170",{"key":30,"text":81,"correct":22},"11000",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},929657,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 4.假定，该结构位于非地震区，仅考虑风荷载作用，且水平风荷载沿竖向呈倒三角形分布，其最大荷载标准值q=65kN\u002Fm，已知该结构各层重力荷载设计值总和为 试问，在上述水平风力作用下，该结构顶点质心的弹性水平位移u（mm）不超过下列何项数值时，方可不考虑重力二阶效应的影响？（ ）",[86,88,90,92],{"key":20,"text":87,"correct":22},"40",{"key":24,"text":89,"correct":32},"50",{"key":27,"text":91,"correct":22},"60",{"key":30,"text":93,"correct":22},"70",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},929658,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 3.假定，该结构对应于x向地震作用标准值的底部总剪力V0=4250kN，相应未经调整的各层框架部分所承担的地震总剪力中的最大值为620kN。试问，抗震设计时，x向地震作用下，相应的底层框架部分承担的地震总剪力（kN）为下列何项数值时符合有关规范、规程的最低要求？（ ）",[98,100,102,104],{"key":20,"text":99,"correct":22},"620",{"key":24,"text":101,"correct":32},"850",{"key":27,"text":103,"correct":22},"900",{"key":30,"text":105,"correct":22},"930",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},929659,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题]",[110,111,113,115],{"key":20,"text":33,"correct":22},{"key":24,"text":112,"correct":32},"2.假定，该建筑物拟作为综合楼使用，二～五层为商场，六～七层为库房，其余楼层作为办公用房。设计时其楼屋面活荷载均按等效均布荷载计算而得，各层荷载标准值如下：①屋面：永久荷载8.8kN\u002Fm2，活荷载2.0kN\u002Fm2，雪荷载0.5kN\u002Fm2；②8～15层：永久荷载8.0kN\u002Fm2，活荷载2.0kN\u002Fm2；③6～7层：永久荷载8.0kN\u002Fm2，活荷载5.0kN\u002Fm2；④2～5层：永久荷载8.0kN\u002Fm2，活荷载3.5kN\u002Fm2。试问，进行地震作用计算时，该结构的总重力荷载代表值GE（kN）应与下列何项数值最为接近？（ ）",{"key":27,"text":114,"correct":22},"提示：1．按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。2．每层面积均按850m2计算，且不考虑楼板开洞影响。",{"key":30,"text":116,"correct":22},"{图2}",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":33},929660,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 1.已知该建筑物位于城市郊区，地面粗糙度为B类，所在地区基本风压W0=0.65kN\u002Fm2，屋顶处的风振系数βz=1.402。试问，在图6-16所示方向的风荷载作用下，屋顶lm高度范围内Y向的风荷载标准值Wk（kN\u002Fm2），与下列何项数值最为接近？（ ） 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。",[121,123,125,127],{"key":20,"text":122,"correct":22},"1.28",{"key":24,"text":124,"correct":32},"1.70",{"key":27,"text":126,"correct":22},"1.91",{"key":30,"text":128,"correct":22},"3.43",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":27,"analysis":33},929661,"某13层钢框架结构，箱形方柱截面如图所示，抗震设防烈度为8度，回转半径ix=iy=173mm，钢材采用Q345（fy=325N\u002Fmm2）。则满足规程要求的最大层高h，应最接近于（ ）mm。 提示： ①按《高层民用建筑钢结构技术规程》（JGJ 99—98）设计； ②柱子的计算长度取层高h。",[133,135,137,139],{"key":20,"text":134,"correct":22},"7800",{"key":24,"text":136,"correct":22},"8200",{"key":27,"text":138,"correct":32},"8800",{"key":30,"text":140,"correct":22},"9200",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":27,"analysis":33},929662,"某13层钢框架结构，箱形方柱截面如图所示，抗震设防烈度为8度，回转半径ix=iy=173mm，钢材采用Q345(fy=325N\u002Fmm2)。则满足规程要求的最大层高h，应最接近于( )mm。 提示： ①按《高层民用建筑钢结构技术规程》(JGJ99-98)设计； ②柱子的计算长度取层高h。",[145,146,147,148],{"key":20,"text":134,"correct":22},{"key":24,"text":136,"correct":22},{"key":27,"text":138,"correct":32},{"key":30,"text":140,"correct":22},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":27,"analysis":33},929664,"某12层现浇钢筋混凝土框架一剪力墙结构，房屋高度45m，抗震设防烈度8度（0.20g），丙类建筑，设计地震分组为第一组，建筑场地类别为Ⅱ类，建筑物平、立面示意如图所示，梁、板混凝土强度等级为C30（fc=14.3N／mm2，ft=1.43N／mm2）；框架柱和剪力墙为C40（fc=19.1N／mm2，ft=1.71N／mm2）。[2014年真题]",[153,154,156,158],{"key":20,"text":33,"correct":22},{"key":24,"text":155,"correct":22},"2.假定，该结构第10层带边框剪力墙墙厚250mm，该楼面处墙内设置宽度同墙厚的暗梁，剪力墙（包括暗梁）主筋采用HRB400（fy=360N／mm2）。试问，暗梁截面顶面纵向钢筋采用下列何项配置时，才最接近且又满足《高层建筑混凝土结构技术规程》（JGJ 3—2010）中的最低构造要求？（ ）",{"key":27,"text":157,"correct":32},"提示：暗梁的抗震等级同剪力墙。",{"key":30,"text":33,"correct":22},{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":27,"analysis":33},929665,"某12层现浇钢筋混凝土框架一剪力墙结构，房屋高度45m，抗震设防烈度8度（0.20g），丙类建筑，设计地震分组为第一组，建筑场地类别为Ⅱ类，建筑物平、立面示意如图所示，梁、板混凝土强度等级为C30（fc=14.3N／mm2，ft=1.43N／mm2）；框架柱和剪力墙为C40（fc=19.1N／mm2，ft=1.71N／mm2）。[2014年真题] 1.假定，在该结构中，各层框架柱数量保持不变，对应于水平地震作用标准值的计算结果为：结构基底总剪力V0=13500kN，各层框架所承担的未经调整的地震总剪力中的最大值Vf，max=1600kN，第3层框架承担的未经调整的地震总剪力Vf=1500kN；该楼层某根柱调整前的柱底内力标准值为：弯矩M=±180kN·m，剪力V=±50kN。试问，抗震设计时，水平地震作用下该柱调整后的内力标准值，与下列何项数值最为接近？（ ） 提示：楼层剪重比满足规程关于楼层最小地震剪力系数（剪重比）的要求。",[163,165,167,169],{"key":20,"text":164,"correct":22},"M=±180kN·m；V=±50kN",{"key":24,"text":166,"correct":22},"M=±270kN·m：V=±75kN",{"key":27,"text":168,"correct":32},"M=±288kN·m；V=±80kN",{"key":30,"text":170,"correct":22},"M=±324kN·m；V=±90kN",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":27,"analysis":33},929666,"某12层钢筋混凝土框架结构，需进行弹性动力时程分析补充计算。已知，振型分解反应谱法求得的底部剪力为12000kN，现有4组实际地震记录加速度时程曲线P1～P4和1组人工模拟加速度时程曲线RP1。各条时程曲线计算所得的结构底部剪力见表。实际记录地震波及人工波的平均地震影响系数曲线与振型分解反应谱法所采用的地震影响系数曲线在统计意义上相符。试问，进行弹性动力时程分析时，选用下列哪一组地震波（包括人工波）最为合理？（ ）[2014年真题] A：P1；P2；P3 B：．P1；P2；RP1 C：．P2；P3；RP1 D：．P2；P4；RP1",[175,177,179,181],{"key":20,"text":176,"correct":22},"a",{"key":24,"text":178,"correct":22},"b",{"key":27,"text":180,"correct":32},"c",{"key":30,"text":182,"correct":22},"d",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":20,"analysis":33},929667,"某11层住宅，采用钢框架结构，其结构质量及刚度沿高度分布基本均匀，各层层高如图所示。抗震设防烈度为7度。 3.假定框架钢材采用Q345，fv=345N\u002Fmm2，某梁柱节点构造如图所示。试问，柱在节点域的腹板最小厚度twc（mm），与下列（ ）项数值最为接近。 提示：按《高层民用建筑钢结构技术规程》（JGJ 99—98）计算。",[187,189,191,193],{"key":20,"text":188,"correct":32},"10",{"key":24,"text":190,"correct":22},"13",{"key":27,"text":192,"correct":22},"15",{"key":30,"text":194,"correct":22},"17",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":20,"analysis":33},929668,"某11层住宅，采用钢框架结构，其结构质量及刚度沿高度分布基本均匀，各层层高如图所示。抗震设防烈度为7度。 {图} 2.假定屋盖和楼盖处重力荷载代表值均为 G，与结构总水平地震作用等效的底部剪力标准值FEk=10000kN，基本自振周期T1=1.1s。试问，顶层总水平地震作用标准值F11Ek（kN），与下列（ ）项数值最为接近。",[199,201,203,205],{"key":20,"text":200,"correct":32},"3000",{"key":24,"text":202,"correct":22},"2400",{"key":27,"text":204,"correct":22},"1600",{"key":30,"text":206,"correct":22},"1400",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":27,"analysis":33},929669,"某11层住宅，采用钢框架结构，其结构质量及刚度沿高度分布基本均匀，各层层高如图所示。抗震设防烈度为7度。 1.假定水平地震影响系数α1=0.22；屋面恒荷载标准值为4300kN，等效活荷载标准值为480kN，雪荷载标准值为160kN；各层楼盖处恒荷载标准值为4100kN，等效活荷载标准值为550kN。试问，结构总水平地震作用标准值FEk（kN），与下列（ ）项数值最为接近。 提示：按《高层民用建筑钢结构技术规程》（JGJ 99—98）底部剪力法计算。",[211,213,215,217],{"key":20,"text":212,"correct":22},"8317",{"key":24,"text":214,"correct":22},"8398",{"key":27,"text":216,"correct":32},"8471",{"key":30,"text":218,"correct":22},"8499",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":27,"analysis":33},929670,"抗震设计的高层建筑混凝土结构，关于地震作用的计算，下列何项符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）的要求？（ ）[2012年真题]",[223,225,227,229],{"key":20,"text":224,"correct":22},"7度抗震设计时，各种结构均不必考虑竖向地震作用",{"key":24,"text":226,"correct":22},"计算双向地震作用时，应考虑偶然偏心的影响",{"key":27,"text":228,"correct":32},"7～9度抗震设防的连体结构，应采用弹性时程分析法进行多遇地震作用下的补充分析",{"key":30,"text":230,"correct":22},"高度不超过40m以弯曲变形为主的高层建筑混凝土结构，可采用底部剪力法计算地震作用",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":20,"analysis":33},929671,"假定，转换层设在一层，一层有8根截面尺寸为900mm×900mm的框支柱（全部截面面积Ac1=6.48m2），二层横向剪力墙有效截面面积Aw2=16.1m2，一～三层墙、柱的混凝土强度等级均为C40。试问，满足《高层建筑混凝土结构技术规程》（JGJ 3—2010），关于转换层上下结构侧向刚要求的底层横向落地剪力墙的最小有效截面面积Aw1（m2），应与下列何项数值最为接近？（ ）[2013年真题]",[235,237,239,241],{"key":20,"text":236,"correct":32},"8.0",{"key":24,"text":238,"correct":22},"10.0",{"key":27,"text":240,"correct":22},"12.0",{"key":30,"text":242,"correct":22},"14.0",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":27,"analysis":33},929672,"假定，一结构中第四层某连梁的截面尺寸为300mm×700mm，抗震等级为一级，净跨为1500mm，为构造配筋，混凝土强度等级C40（ft=1.71N／mm2），纵筋及箍筋均采用HRB400钢筋（fy=360N／mm2）。试问，符合规范规程最低要求的连梁的纵筋和箍筋配置，应选用下列何项数值？（ ）[2013年真题]",[247,248,249,250],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":27,"analysis":33},929673,"黑龙江省佳木斯西北方向某县的一多层建筑在设计时，《建筑结构荷载规范》（GB 50009—2012）附录E中没有给出该县的基本雪压，但当地气象部门给出年最大积雪深度为0.50m，由此设计单位可按《建筑结构荷载规范》（GB 50009—2012）附录E第 E.1.2条规定确定雪压值s＝（ ）kN\u002Fm2。",[255,257,259,261],{"key":20,"text":256,"correct":22},"0.50",{"key":24,"text":258,"correct":22},"0.60",{"key":27,"text":260,"correct":32},"0.74",{"key":30,"text":262,"correct":22},"0.80",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":27,"analysis":33},929674,"黑龙江省佳木斯西北方向某县的一多层建筑在设计时，《建筑结构荷载规范》(GB 50009-2001)(2006年版)附录D中没有给出该县的基本雪压，但当地气象部门给出年最大积雪深度为0.50m，由此设计单位可按《建筑结构荷载规范》(GB 50009-2001) (2006年版)附录D第 D.1.2条规定确定雪压值s=( )kN\u002Fm2。",[267,268,269,270],{"key":20,"text":256,"correct":22},{"key":24,"text":258,"correct":22},{"key":27,"text":260,"correct":32},{"key":30,"text":262,"correct":22},{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":30,"analysis":33},929675,"关于柱轴压比限值的要求，下列各项不正确的是( )。",[275,277,279,281],{"key":20,"text":276,"correct":22},"框支剪力墙结构，抗震等级属于一级的框支柱(包括框支角柱)，其轴压比不宜大于0.60",{"key":24,"text":278,"correct":22},"框架一剪力墙结构，抗震等级属一级的框架柱，当剪力墙部分承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其框架柱轴压比不宜大于0.70",{"key":27,"text":280,"correct":22},"框架一核心筒结构，抗震等级属一级的框架柱，当核心筒结构承受的地震倾覆力矩大于结构总地震倾覆力矩的50%时，其框架柱轴压比不宜大于0.75",{"key":30,"text":282,"correct":32},"筒中筒结构，抗震等级属一级的密集柱，沿柱全高采用井字复合箍，箍筋间距 100mm.肢距150mm.箍径12mm；其内筒承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其密集柱的轴压比不宜大于0.75",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":20,"analysis":33},929676,"对于底部大空间剪力墙结构的转换层楼面，下列符合规定的是（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":32},"应采用现浇楼板，其混凝土强度等级不应低于C30，并应双层双向配筋，且每层每向的配筋率不宜小于0.25%",{"key":24,"text":290,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于C25，并应双层双向配筋，且每层每向的配筋率不宜小于0.25%",{"key":27,"text":292,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于C30，并应双层双向配筋，且每层每向的配筋率不宜小于0.20%",{"key":30,"text":294,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于C25，并应双层双向配筋，且每层每向的配筋率不宜小于0.20%",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":20,"analysis":33},929677,"对于底部大空间剪力墙结构的转换层楼面，下列符合规定的是( )。",[299,301,303,305],{"key":20,"text":300,"correct":32},"应采用现浇楼板，其混凝土强度等级不应低于 C.30，并应双层双向配筋，且每层每向的配筋率不宜小于0.25%",{"key":24,"text":302,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于 C.25，并应双层双向配筋，且每层每向的配筋率不宜小于0.25%",{"key":27,"text":304,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于30，并应双层双向配筋，且每层每向的配筋率不宜小于0.20%",{"key":30,"text":306,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于25，并应双层双向配筋，且每层每向的配筋率不宜小于0.20%",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":30,"analysis":33},929678,"对框架一核心筒结构进行结构布置时，下列概念不正确的是( )。",[311,313,315,317],{"key":20,"text":312,"correct":22},"核心筒是框架一核心筒结构抵抗侧向力的最主要构件，核心筒需占有一定的面积，以获得受力所需的侧向刚度",{"key":24,"text":314,"correct":22},"为了尽可能地减少扭矩，宜布置核心筒位于整个结构的中央，筒外形对称，甚至筒内墙肢也宜均匀.对称设置，以适应框架一核心筒结构对扭矩较敏感的特点",{"key":27,"text":316,"correct":22},"为保证框架一核心筒结构的侧向刚度沿竖向不发生突变，宜将核心筒贯通建筑物的全高",{"key":30,"text":318,"correct":32},"为降低层高和方便铺设管线，同时也避免楼盖主梁搁置在核心筒的连梁上，可采用无梁楼盖将核心筒与周边柱.内柱连成整体，因此，周边柱之间的框架梁也可一并省去",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":30,"analysis":33},929679,"对框架—核心筒结构进行结构布置时，下列概念不正确的是（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"核心筒是框架—核心筒结构抵抗侧向力的最主要构件，核心筒需占有一定的面积，以获得受力所需的侧向刚度",{"key":24,"text":326,"correct":22},"为了尽可能地减少扭矩，宜布置核心筒位于整个结构的中央，筒外形对称，甚至筒内墙肢也宜均匀.对称设置，以适应框架—核心筒结构对扭矩较敏感的特点",{"key":27,"text":328,"correct":22},"为保证框架—核心筒结构的侧向刚度沿竖向不发生突变，宜将核心筒贯通建筑物的全高",{"key":30,"text":318,"correct":32},{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},929680,"10层框架—剪力墙结构，抗震设防烈度为8度，Ⅱ类场地，设计地震分组：第一组。首层层高6m，2层层高4.5m，3～10层层高3.6m，总高度39.3m。质量和刚度沿高度分布比较均匀，各楼层重力荷载代表值Gi如图所示。各楼层框架的Di值及剪力墙等效刚度如表6-5所列。采用侧移法计算在连续均布荷载作用下结构假想顶点位移μT=ψuqH4\u002F100EIw，并已知当结构刚度特征值λ=1.2时位移系数ψu=8.07。结构阻尼比ζ=0.05。 3.假定结构自振周期为T1=0.793s，结构底部由水平地震作用产生的总弯矩标准值M0（kN·m）与（ ）项数值最为接近。",[334,336,338,340],{"key":20,"text":335,"correct":32},"137981",{"key":24,"text":337,"correct":22},"154368",{"key":27,"text":339,"correct":22},"194018",{"key":30,"text":341,"correct":22},"202112",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":33},929681,"10层框架—剪力墙结构，抗震设防烈度为8度，Ⅱ类场地，设计地震分组：第一组。首层层高6m，2层层高4.5m，3～10层层高3.6m，总高度39.3m。质量和刚度沿高度分布比较均匀，各楼层重力荷载代表值Gi如图所示。各楼层框架的Di值及剪力墙等效刚度如表6-5所列。采用侧移法计算在连续均布荷载作用下结构假想顶点位移μT=ψuqH4\u002F100EIw，并已知当结构刚度特征值λ=1.2时位移系数ψu=8.07。结构阻尼比ζ=0.05。 2.若结构自振周期T1=0.68s，则T1相对应的地震影响系数α1与（ ）项数值最为接近。",[346,348,350,352],{"key":20,"text":347,"correct":22},"0.077",{"key":24,"text":349,"correct":32},"0.088",{"key":27,"text":351,"correct":22},"0.112",{"key":30,"text":353,"correct":22},"0.16",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":24,"analysis":33},929682,"10层框架—剪力墙结构，抗震设防烈度为8度，Ⅱ类场地，设计地震分组：第一组。首层层高6m，2层层高4.5m，3～10层层高3.6m，总高度39.3m。质量和刚度沿高度分布比较均匀，各楼层重力荷载代表值Gi如图所示。各楼层框架的Di值及剪力墙等效刚度如表6-5所列。采用侧移法计算在连续均布荷载作用下结构假想顶点位移μT=ψuqH4\u002F100EIw，并已知当结构刚度特征值λ=1.2时位移系数ψu=8.07。结构阻尼比ζ=0.05。 1.未考虑非结构构件刚度影响时的结构基本自振周期T1（s），最接近于（ ）项数值。",[358,360,362,364],{"key":20,"text":359,"correct":22},"0.5",{"key":24,"text":361,"correct":32},"0.9",{"key":27,"text":363,"correct":22},"1.2",{"key":30,"text":365,"correct":22},"1.7",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":33},929683,"一商店建筑中有一挑出长度为8m的长悬挑梁，梁上作用着永久荷载标准值的线荷载gk=30kN\u002Fm，楼面活荷载标准值的线荷载qk=20kN\u002Fm（见图）。该建筑的抗震设防烈度为8度（0.30g）。由此可算得梁端A处的最大弯矩设计值MA=（ ）kN·m。 提示：计算时应对有无竖向地震作用，以及比较永久荷载效应控制的组合与可变荷载效应控制的组合，然后确定最大弯矩设计值MA。",[370,372,374,376],{"key":20,"text":371,"correct":32},"2048.0",{"key":24,"text":373,"correct":22},"1923.2",{"key":27,"text":375,"correct":22},"1800.0",{"key":30,"text":377,"correct":22},"1785.6",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":27,"analysis":33},929684,"图所示为一个8层钢筋混凝土框架结构的平面图。该建筑抗震烈度为8度，属于二级抗震等级。下列结构动力分析方法中，正确的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"只要作横向的平动振型抗震验算，因为纵向（y向）的抗侧刚度较弱",{"key":24,"text":385,"correct":22},"只要作横向的抗震验算和纵向的抗震验算",{"key":27,"text":387,"correct":32},"除作x.y向的平动振型的抗震验算外，还要作扭转振型的耦联计算",{"key":30,"text":389,"correct":22},"该结构属于简单的纯框架，层数也不高，用基底剪力法计算其横向的水平地震力，并按各榀框架的抗侧刚度进行分配",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":30,"analysis":33},929685,"某矩形框筒，平面尺寸如图所示，总高度102m，承受水平力q=20kN\u002Fm，框筒截面可简化成双槽形截面，该截面如图6-38所示。角柱为L形、截面面积A3=6.41m2、形心坐标y=0.90m。槽形截面惯性矩为3056.5m4。计算图中底层3号柱所受的轴力N3最接近于（ ）kN。",[394,396,398,400],{"key":20,"text":395,"correct":22},"1564.9",{"key":24,"text":397,"correct":22},"1711.4",{"key":27,"text":399,"correct":22},"1956.2",{"key":30,"text":401,"correct":32},"2094.8",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":30,"analysis":33},929686,"关于柱轴压比限值的要求，下列各项不正确的是（ ）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"框支剪力墙结构，抗震等级属于一级的框支柱（包括框支角柱），其轴压比不宜大于0.60",{"key":24,"text":409,"correct":22},"框架—剪力墙结构，抗震等级属一级的框架柱，当剪力墙部分承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其框架柱轴压比不宜大于0.65",{"key":27,"text":411,"correct":22},"框架—核心筒结构，抗震等级属一级的框架柱，当核心筒结构承受的地震倾覆力矩大于结构总地震倾覆力矩的50%时，其框架柱轴压比不宜大于0.75",{"key":30,"text":413,"correct":32},"筒中筒结构，抗震等级属一级的密集柱，沿柱全高采用井字复合箍，箍筋间距100mm.肢距150mm.箍径12mm；其内筒承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其密集柱的轴压比不宜大于0.75",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":30,"analysis":33},929687,"某10层钢筋混凝土框架结构，如图所示，质量和刚度沿竖向分布比较均匀，抗震设防类别为标准设防类，抗震设防烈度7度，设计基本地震加速度0.10g，设计地震分组第一组，场地类别Ⅱ类。[2014年真题] 2.假定，该框架结构进行方案调整后，结构的基本自振周期T1=1.10s，总水平地震作用标准值FEk=3750kN。试问，作用于该结构顶部附加水平地震作用△F10（kN），与下列何项数值最为接近？（ ）",[418,420,422,424],{"key":20,"text":419,"correct":22},"210",{"key":24,"text":421,"correct":22},"260",{"key":27,"text":423,"correct":22},"370",{"key":30,"text":425,"correct":32},"590",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":24,"analysis":33},929688,"某10层钢筋混凝土框架结构，如图所示，质量和刚度沿竖向分布比较均匀，抗震设防类别为标准设防类，抗震设防烈度7度，设计基本地震加速度0.10g，设计地震分组第一组，场地类别Ⅱ类。[2014年真题] 3.假定，该结构楼层屈服强度系数沿高度分布均匀，底层屈服强度系数为0.45，且不小于上层该系数的0.8，底层柱的轴压比为0.60。试问，在罕遇地震作用下按弹性分析的层间位移（mm），最大不超过下列何值时，才能满足结构弹塑性水平位移限值要求？（ ） 提示：不考虑重力二阶效应；可考虑柱子箍筋构造措施的提高。",[430,432,434,436],{"key":20,"text":431,"correct":22},"46",{"key":24,"text":433,"correct":32},"56",{"key":27,"text":435,"correct":22},"66",{"key":30,"text":437,"correct":22},"76",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":33},929689,"某10层钢筋混凝土框架结构，如图所示，质量和刚度沿竖向分布比较均匀，抗震设防类别为标准设防类，抗震设防烈度7度，设计基本地震加速度0.10g，设计地震分组第一组，场地类别Ⅱ类。[2014年真题] 6.假定，框架中间层边框架节点如图6-3所示。梁端A处由重力荷载代表值产生的弯矩标准值MG=－135kN·m，水平地震作用产生的弯矩标准值ME=±130kN·m，风荷载产生的弯矩标准值Mw=±80kN·m。试问，框架梁端（A—A处）在考虑弯矩调幅后（调幅系数0.85），地震设计状况下梁顶最不利组合弯矩设计值MA（kN·m），与下列何项数值最为接近？（ ）",[442,444,446,448],{"key":20,"text":443,"correct":22},"250",{"key":24,"text":445,"correct":32},"310",{"key":27,"text":447,"correct":22},"350",{"key":30,"text":449,"correct":22},"440",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":24,"analysis":33},929690,"在一展览馆的楼面上，有一静止的展品及其墩座，其自重的标准值共为30kN；墩座经厚50mm的垫层坐落在板跨为3m（单向板）、板厚为150mm的钢筋混凝土楼板上。该展品的四周无其他展品的展览区（见图）。 l——板跨；bcx、bcy——分别为平行、垂直于板跨的荷载作用面的计算宽度；b——局部分布荷载的有效分布宽度。 1.单向板上，由墩座和展品这一局部荷载在板中产生的最大弯矩Mmax最接近于（ ）kN·m。",[454,456,458,460],{"key":20,"text":455,"correct":22},"22.5",{"key":24,"text":457,"correct":32},"21.19",{"key":27,"text":459,"correct":22},"20.02",{"key":30,"text":461,"correct":22},"19.03",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":24,"analysis":33},929691,"在一展览馆的楼面上，有一静止的展品及其墩座，其自重的标准值共为30kN；墩座经厚50mm的垫层坐落在板跨为3m（单向板）、板厚为150mm的钢筋混凝土楼板上。该展品的四周无其他展品的展览区（见图）。 l——板跨；bcx、bcy——分别为平行、垂直于板跨的荷载作用面的计算宽度；b——局部分布荷载的有效分布宽度。 2.单向板上局部荷载的有效分布宽度b最接近于（ ）m。",[466,468,470,472],{"key":20,"text":467,"correct":22},"3.27",{"key":24,"text":469,"correct":32},"2.85",{"key":27,"text":471,"correct":22},"2.69",{"key":30,"text":473,"correct":22},"0.75",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":20,"analysis":33},929692,"在一展览馆的楼面上，有一静止的展品及其墩座，其自重的标准值共为30kN；墩座经厚50mm的垫层坐落在板跨为3m（单向板）、板厚为150mm的钢筋混凝土楼板上。该展品的四周无其他展品的展览区（见图）。 l——板跨；bcx、bcy——分别为平行、垂直于板跨的荷载作用面的计算宽度；b——局部分布荷载的有效分布宽度。 3.单向板上在（b×l）面积上的等效均布荷载q最接近于（ ）kN\u002Fm2。",[478,480,482,484],{"key":20,"text":479,"correct":32},"10.11",{"key":24,"text":481,"correct":22},"6.61",{"key":27,"text":483,"correct":22},"4.8",{"key":30,"text":485,"correct":22},"3.5",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":24,"analysis":33},929693,"一单层平面框架（见图），由屋顶永久荷载标准值产生的D点柱顶弯矩标准值MDgk=50kN·m。 1.由屋顶均布活荷载标准值产生的弯矩标准值MDqk=30kN·m，则D点的弯矩设计值MD最接近于（ ）kN·m。",[490,492,494,496],{"key":20,"text":491,"correct":22},"130",{"key":24,"text":493,"correct":32},"102",{"key":27,"text":495,"correct":22},"96.9",{"key":30,"text":497,"correct":22},"95",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":27,"analysis":33},929694,"一单层平面框架（见图），由屋顶永久荷载标准值产生的D点柱顶弯矩标准值MDgk=50kN·m。 现尚需计及如图所示由风荷载产生的D点弯矩标准值MDwk=25kN·m，由此算得D点组合后的弯矩设计值MD最接近于（ ）kN·m。（不采用简化规则）",[502,504,506,508],{"key":20,"text":503,"correct":22},"117.9",{"key":24,"text":505,"correct":22},"123.0",{"key":27,"text":507,"correct":32},"124.4",{"key":30,"text":509,"correct":22},"140.0",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":27,"analysis":33},929695,"一钢筋混凝土排架，由于三种荷载（不包括柱自重）使排架柱柱脚A处产生三个柱脚弯矩标准值，MAgk=50kN·m、MAqk=30kN·m、MAck=60kN·m（见图6-28（a）、（b）、（c）），MAgk是柱顶处屋面桁架上永久荷载的偏心反力产生的，MAqk是柱顶处屋面桁架上活荷载的偏心反力产生的，MAck是柱中部吊车梁上A5级软钩吊车荷载的偏心反力产生的。风荷载作用下产生的柱脚弯矩标准值MAwk=65kN·m（见图）。 1.由桁架上永久荷载、活荷载和吊车荷载产生的柱脚最大弯矩设计值MA应为（ ）kN·m。计算时对效应的组合不采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则。",[514,516,518,520],{"key":20,"text":515,"correct":22},"160.8",{"key":24,"text":517,"correct":22},"166",{"key":27,"text":519,"correct":32},"173.4",{"key":30,"text":521,"correct":22},"180",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":30,"analysis":33},929696,"一钢筋混凝土排架，由于三种荷载（不包括柱自重）使排架柱柱脚A处产生三个柱脚弯矩标准值，MAgk=50kN·m、MAqk=30kN·m、MAck=60kN·m（见图6-28（a）、（b）、（c）），MAgk是柱顶处屋面桁架上永久荷载的偏心反力产生的，MAqk是柱顶处屋面桁架上活荷载的偏心反力产生的，MAck是柱中部吊车梁上A5级软钩吊车荷载的偏心反力产生的。风荷载作用下产生的柱脚弯矩标准值MAwk=65kN·m（见图）。 2.还需考虑风荷载作用下产生的柱脚弯矩。由桁架上永久荷载和三种可变荷载确定的柱脚最大弯矩设计值MA应为（ ）kN·m。计算时对效应的组合不采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则。",[526,528,530,532],{"key":20,"text":527,"correct":22},"215.4",{"key":24,"text":529,"correct":22},"228",{"key":27,"text":531,"correct":22},"230",{"key":30,"text":533,"correct":32},"239.2",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":20,"analysis":33},929697,"一钢筋混凝土排架，由于三种荷载（不包括柱自重）使排架柱柱脚A处产生三个柱脚弯矩标准值，MAgk=50kN·m、MAqk=30kN·m、MAck=60kN·m（见图6-28（a）、（b）、（c）），MAgk是柱顶处屋面桁架上永久荷载的偏心反力产生的，MAqk是柱顶处屋面桁架上活荷载的偏心反力产生的，MAck是柱中部吊车梁上A5级软钩吊车荷载的偏心反力产生的。风荷载作用下产生的柱脚弯矩标准值MAwk=65kN·m（见图）。 3.采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则，计算在四种荷载下柱脚A处的最大弯矩设计值MA应为（ ）kN·m。",[538,540,541,542],{"key":20,"text":539,"correct":32},"255.3",{"key":24,"text":533,"correct":22},{"key":27,"text":529,"correct":22},{"key":30,"text":543,"correct":22},"210.3",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":20,"analysis":33},929698,"某单层工业厂房，厂房柱距12m，采用工字形截面的实腹式钢吊车梁。设置有两台Q＝25\u002F10t的软钩桥式吊车，吊车每侧有两个车轮，轮距4m，最大轮压标准值Pkmax＝279.7kN，横行小车质量标准值Q1＝73.5kN，吊车轨道高度hR＝130mm。 1.当吊车为中级工作制时，作用在每个车轮处的横向水平荷载标准值最接近于（ ）kN。",[548,549,551,553],{"key":20,"text":236,"correct":32},{"key":24,"text":550,"correct":22},"11.1",{"key":27,"text":552,"correct":22},"15.9",{"key":30,"text":554,"correct":22},"22.2",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":27,"analysis":33},929699,"某单层工业厂房，厂房柱距12m，采用工字形截面的实腹式钢吊车梁。设置有两台Q＝25\u002F10t的软钩桥式吊车，吊车每侧有两个车轮，轮距4m，最大轮压标准值Pkmax＝279.7kN，横行小车质量标准值Q1＝73.5kN，吊车轨道高度hR＝130mm。 2.假定吊车为重级工作制时，作用在每个车轮处的横向水平荷载标准值最接近于（ ）kN。",[559,560,561,563],{"key":20,"text":236,"correct":22},{"key":24,"text":242,"correct":22},{"key":27,"text":562,"correct":32},"28.0",{"key":30,"text":564,"correct":22},"42.0",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":24,"analysis":33},929700,"某地上16层、地下1层的现浇钢筋混凝土框架-剪力墙办公楼，如图所示。房屋高度为64.2m，该建筑地下室至地上第3层的层高均为4.5m，其余各层层高均为3.9m，质量和刚度沿高度分布比较均匀，丙类建筑，抗震设防烈度为7度，设计基本地震加速度为0.15g，设计地震分组为第一组，Ⅲ类场地，在规定的水平力作用下，结构底层框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的10％但不大于50％，地下1层顶板为上部结构的嵌固端。构件混凝土强度等级均为C40 4.地上第3层某L形剪力墙墙肢的截面如图所示，墙肢轴压比为0.24。试问，该剪力墙转角处边缘构件（图中阴影部分）的纵向钢筋面积 最小取下列何项数值时才能满足规范、规程的最低构造要求？（ ） 提示：不考虑承载力计算要求。",[569,571,573,575],{"key":20,"text":570,"correct":22},"2700",{"key":24,"text":572,"correct":32},"3300",{"key":27,"text":574,"correct":22},"3500",{"key":30,"text":576,"correct":22},"3800",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":27,"analysis":33},929701,"某地上16层、地下1层的现浇钢筋混凝土框架-剪力墙办公楼，如图所示。房屋高度为64.2m，该建筑地下室至地上第3层的层高均为4.5m，其余各层层高均为3.9m，质量和刚度沿高度分布比较均匀，丙类建筑，抗震设防烈度为7度，设计基本地震加速度为0.15g，设计地震分组为第一组，Ⅲ类场地，在规定的水平力作用下，结构底层框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的10％但不大于50％，地下1层顶板为上部结构的嵌固端。构件混凝土强度等级均为C40 5.假定，该建筑所在地区的基本风压为0.40kN／m2（50年一遇），地面粗糙度为B类，风向如图所示，风载沿房屋高度方向呈倒三角形分布，地面处（±0.000）为0，屋顶高度处风振系数为1.42，L形剪力墙厚度均为300mm。试问，承载力设计时，在图示风向风荷载标准值作用下，在（±0.000）处产生的倾覆力矩标准值Mwk(kN·m)与下列何项数值最为接近？（ ） 提示：①按《高层建筑混凝土结构技术规程》（JGJ 3—2010）计算风荷载体型系数； ②假定风作用面宽度为24.3m。",[581,583,585,587],{"key":20,"text":582,"correct":22},"42000",{"key":24,"text":584,"correct":22},"47000",{"key":27,"text":586,"correct":32},"52000",{"key":30,"text":588,"correct":22},"68000",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":24,"analysis":33},929702,"某地上16层、地下1层的现浇钢筋混凝土框架-剪力墙办公楼，如图所示。房屋高度为64.2m，该建筑地下室至地上第3层的层高均为4.5m，其余各层层高均为3.9m，质量和刚度沿高度分布比较均匀，丙类建筑，抗震设防烈度为7度，设计基本地震加速度为0.15g，设计地震分组为第一组，Ⅲ类场地，在规定的水平力作用下，结构底层框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的10％但不大于50％，地下1层顶板为上部结构的嵌固端。构件混凝土强度等级均为C40",[593,595,597,599],{"key":20,"text":594,"correct":22},"107",{"key":24,"text":596,"correct":32},"157",{"key":27,"text":598,"correct":22},"200",{"key":30,"text":443,"correct":22},[601,604,607,610,613,616],{"id":15,"name":602,"category":7,"favorite":603},"领导干部任职前廉政法规知识测试题",92,{"id":605,"name":606,"category":7,"favorite":15},595,"建筑结构与设备",{"id":608,"name":609,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":611,"name":612,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":614,"name":615,"category":7,"favorite":8},534,"BIM工程师",{"id":617,"name":615,"category":7,"favorite":8},535]