[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-22":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":576},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,22,50,1330,[13,34,46,58,69,79,88,100,112,120,131,143,154,166,178,190,199,207,219,231,243,255,263,275,287,295,307,319,331,343,351,363,375,387,395,406,418,426,438,449,459,468,480,492,504,516,528,540,552,564],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},929602,1,"单选题","某现浇钢筋混凝土框架—剪力墙办公楼，地上11层，每层层高均为3.6m，房屋高度为39.9m，抗震设防烈度为9度，设计基本加速度为0.4g，设计地震分组为第一组，Ⅱ类场地，丙类建筑。若各楼面恒载标准均为12000kN，各楼层等效活载标准值均为1800kN，屋面层恒载标准值为16000kN，屋面活载标准值为1300kN，屋面雪载标准值为1000kN，结构基本自振周期T1=0.9s（已考虑非承重墙体的影响）。试问，结构总竖向地震作用标准值 与下列何项数值最接近？（ ）[2012年真题]",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","22500",false,{"key":24,"text":25,"correct":26},"B","22700",true,{"key":28,"text":29,"correct":22},"C","25400",{"key":31,"text":32,"correct":22},"D","25700","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},929603,"某三跨框架结构，抗震等级为二级，边跨跨度为5.7m，框架梁截面宽250mm，高600mm，柱宽为500mm，纵筋采用HRB335钢，箍筋采用HPB300钢，混凝土强度等级为C30，重力荷载引起的剪力VGb=135.2kN。在重力荷载和地震作用组合下作用于边跨一层梁上的弯矩为： 梁左端：Mmax=210kN·m，－Mmax=－420kN·m； 梁右端：Mmax=175kN·m，－Mmax=－360kN·m； 梁跨中：Mmax=180kN·m； 边跨梁：V=230kN。 3.计算该框架梁的剪力设计值Vb，最接近于（ ）kN。",[38,40,42,44],{"key":20,"text":39,"correct":22},"230",{"key":24,"text":41,"correct":22},"257.5",{"key":28,"text":43,"correct":26},"272.5",{"key":31,"text":45,"correct":22},"282.7",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},929604,"某三跨框架结构，抗震等级为二级，边跨跨度为5.7m，框架梁截面宽250mm，高600mm，柱宽为500mm，纵筋采用HRB335钢，箍筋采用HPB300钢，混凝土强度等级为C30，重力荷载引起的剪力VGb=135.2kN。在重力荷载和地震作用组合下作用于边跨一层梁上的弯矩为： 梁左端：Mmax=210kN·m，－Mmax=－420kN·m； 梁右端：Mmax=175kN·m，－Mmax=－360kN·m； 梁跨中：Mmax=180kN·m； 边跨梁：V=230kN。 2.若梁左端梁底已配置2φ25的钢筋，则梁顶钢筋As最接近于（ ）mm2。",[50,52,54,56],{"key":20,"text":51,"correct":22},"1170",{"key":24,"text":53,"correct":22},"1672",{"key":28,"text":55,"correct":22},"1964",{"key":31,"text":57,"correct":26},"1992",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},929605,"某三跨框架结构，抗震等级为二级，边跨跨度为5.7m，框架梁截面宽250mm，高600mm，柱宽为500mm，纵筋采用HRB335钢，箍筋采用HPB300钢，混凝土强度等级为C30，重力荷载引起的剪力VGb=135.2kN。在重力荷载和地震作用组合下作用于边跨一层梁上的弯矩为： 梁左端：Mmax=210kN·m，－Mmax=－420kN·m； 梁右端：Mmax=175kN·m，－Mmax=－360kN·m； 梁跨中：Mmax=180kN·m； 边跨梁：V=230kN。 1.计算梁跨中截面正截面所需纵筋As，最接近于（ ）mm2。",[62,64,66,68],{"key":20,"text":63,"correct":22},"393",{"key":24,"text":65,"correct":22},"685",{"key":28,"text":67,"correct":26},"850",{"key":31,"text":51,"correct":22},{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":20,"analysis":33},929606,"某普通住宅，采用现浇钢筋混凝土部分框支剪力墙结构，房屋高度为40.9m。地下1层，地上13层，首层～三层层高分别为4.5m、4.2m、3.9m，其余各层层高均为2.8m，抗震设防烈度为7度，Ⅱ类建筑场地。第3层设转换层，纵横向均有落地剪力墙，地下一层顶板可作为上部结构的嵌固部位。[2013年真题]",[73,75,77,78],{"key":20,"text":74,"correct":26},"5.假定，该结构第四层某剪力墙，其中一端截面为矩形，如图6-9所示，墙肢长度为6000mm，墙厚为250mm，箍筋保护层厚度为15mm，抗震等级为一级，重力荷载代表值作用下的轴压比μN=0.40，混凝土强度等级C40（fc=19.1N／mm2）。纵筋及箍筋采用HRB400钢筋（fy=360N／mm2）。试问，该剪力墙矩形截面端，满足规程最低要求的边缘构件阴影部分长度ac和最小箍筋配置，与下列何项最为接近？（ ）",{"key":24,"text":76,"correct":22},"提示：不考虑水平分布钢筋的影响。",{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":20,"analysis":33},929607,"某普通住宅，采用现浇钢筋混凝土部分框支剪力墙结构，房屋高度为40.9m。地下1层，地上13层，首层～三层层高分别为4.5m、4.2m、3.9m，其余各层层高均为2.8m，抗震设防烈度为7度，Ⅱ类建筑场地。第3层设转换层，纵横向均有落地剪力墙，地下一层顶板可作为上部结构的嵌固部位。[2013年真题] 4.假定，该建筑底层某落地剪力墙Q1，其稳定计算示意图如图所示，混凝土强度级采用",[83,84,86,87],{"key":20,"text":33,"correct":26},{"key":24,"text":85,"correct":22},"试问，满足剪力墙腹板墙肢局部稳定要求时，作用于400mm厚墙肢顶部组合的最大等效竖向均布荷载设计值q（kN／m），与下列何项数值最为接近？（ ）",{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":28,"analysis":33},929608,"某普通住宅，采用现浇钢筋混凝土部分框支剪力墙结构，房屋高度为40.9m。地下1层，地上13层，首层～三层层高分别为4.5m、4.2m、3.9m，其余各层层高均为2.8m，抗震设防烈度为7度，Ⅱ类建筑场地。第3层设转换层，纵横向均有落地剪力墙，地下一层顶板可作为上部结构的嵌固部位。[2013年真题] 3.假定，首层某根框支角柱C1，在地震作用下，其柱底轴力标准值NEk=1680kN；在重力荷载代表值作用下，其柱底轴力标准值NGE=2950kN。框支柱抗震等级为一级，不考虑风荷载。试问，考虑地震作用组合进行截面配筋计算时，柱C1柱底的轴力最大设计值（kN）与下列何项数值最为接近？（ ）",[92,94,96,98],{"key":20,"text":93,"correct":22},"5720",{"key":24,"text":95,"correct":22},"6160",{"key":28,"text":97,"correct":26},"6820",{"key":31,"text":99,"correct":22},"7150",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":28,"analysis":33},929609,"某普通住宅，采用现浇钢筋混凝土部分框支剪力墙结构，房屋高度为40.9m。地下1层，地上13层，首层～三层层高分别为4.5m、4.2m、3.9m，其余各层层高均为2.8m，抗震设防烈度为7度，Ⅱ类建筑场地。第3层设转换层，纵横向均有落地剪力墙，地下一层顶板可作为上部结构的嵌固部位。[2013年真题] 2.假定，方案调整后，首层某剪力墙墙肢W1，抗震措施的抗震等级为一级，墙肢底部截面考虑地震作用组合的内力计算值为：弯矩Mw=3500kN·m，剪力Vw=850kN。试问，W1墙肢底部截面的内力设计值最接近于下列何项数值？（ ）",[104,106,108,110],{"key":20,"text":105,"correct":22},"M=3500kN·m，V=1360kN",{"key":24,"text":107,"correct":22},"M=4550kN·m，V=1190kN",{"key":28,"text":109,"correct":26},"M=5250kN·m，V=1360kN",{"key":31,"text":111,"correct":22},"M=6300kN·m，V=1615kN",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":31,"analysis":33},929610,"某普通住宅，采用现浇钢筋混凝土部分框支剪力墙结构，房屋高度为40.9m。地下1层，地上13层，首层～三层层高分别为4.5m、4.2m、3.9m，其余各层层高均为2.8m，抗震设防烈度为7度，Ⅱ类建筑场地。第3层设转换层，纵横向均有落地剪力墙，地下一层顶板可作为上部结构的嵌固部位。[2013年真题] 1.假定，底部加强部位某片剪力墙的厚度为300mm。试问，该剪力墙底部加强部位的设置高度和剪力墙竖向分布钢筋，至少应取下列哪项才能符合规范、规程的最低要求？（ ）",[116,117,118,119],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":24,"analysis":33},929611,"某拟建工程，房屋高度为57.6m，地下2层，地上15层，首层层高为6.0m，二层层高为4.5m，其余各层层高均为3.6m。采用现浇钢筋混凝土框架。剪力墙结构，抗震设防烈度为7度，丙类建筑，设计基本地震加速度为0.15g，Ⅲ类场地。混凝土强度等级采用C40（fc=19.1N／mm2）。在规定的水平力作用下结构总地震倾覆力矩 底层剪力墙承受的地震倾覆力矩 5.假定，方案调整后，该结构中部未加剪力墙的某一榀框架如图6-7所示（地下部分未示出），框架抗震等级为二级。作用在底层边柱AB底截面A处的考虑地震作用组合的弯矩设计值MA=580kN·m，剪力计算值VA=230kN。按式 调整后，柱AB上端考虑地震作用组合的弯矩设计值MB=620kN?m（与MA同时针方向）。柱净高Hn=5.4m。试问，当柱AB进行底部截面配筋设计时，其剪力设计值（kN）最接近于下列何项数值？（ ） .",[124,125,127,129],{"key":20,"text":39,"correct":22},{"key":24,"text":126,"correct":26},"270",{"key":28,"text":128,"correct":22},"330",{"key":31,"text":130,"correct":22},"360",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":24,"analysis":33},929612,"某拟建工程，房屋高度为57.6m，地下2层，地上15层，首层层高为6.0m，二层层高为4.5m，其余各层层高均为3.6m。采用现浇钢筋混凝土框架。剪力墙结构，抗震设防烈度为7度，丙类建筑，设计基本地震加速度为0.15g，Ⅲ类场地。混凝土强度等级采用C40（fc=19.1N／mm2）。在规定的水平力作用下结构总地震倾覆力矩 底层剪力墙承受的地震倾覆力矩 4.假定，该结构进行方案调整后，在规定的水平力作用下，框架所承担的地震倾覆力矩占结构总地震倾覆力矩的35％，且结构各层框架柱数量不变，对应于地震作用标准值的结构底部总剪力V0=8950kN（各层水平地震剪力均满足规范、规程关于楼层最小水平地震剪力的规定），对应于地震作用标准值且未经调整的各层框架承担的地震总剪力中的最大值Vf，max=1060kN。试问，调整后首层框架总剪力标准值（kN），应取用下列何项数值？（ ）",[135,137,139,141],{"key":20,"text":136,"correct":22},"1790",{"key":24,"text":138,"correct":26},"1590",{"key":28,"text":140,"correct":22},"1390",{"key":31,"text":142,"correct":22},"1060",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":28,"analysis":33},929613,"某拟建工程，房屋高度为57.6m，地下2层，地上15层，首层层高为6.0m，二层层高为4.5m，其余各层层高均为3.6m。采用现浇钢筋混凝土框架。剪力墙结构，抗震设防烈度为7度，丙类建筑，设计基本地震加速度为0.15g，Ⅲ类场地。混凝土强度等级采用C40（fc=19.1N／mm2）。在规定的水平力作用下结构总地震倾覆力矩 底层剪力墙承受的地震倾覆力矩 3.假定，该结构首层框架，对应于水平地震作用标准值的框架柱总剪力Vf=2400kN，框架柱的侧向刚度总和 其中某边柱C1的侧向刚度DC1=17220kN／m，其反弯点高度hy=3.75m，沿柱高范围没有水平力作用。试问，在水平地震作用下，按侧向刚度计算的C1柱底弯矩标准值（kN·m），与下列何项数值最为接近？（ ）",[147,149,150,152],{"key":20,"text":148,"correct":22},"240",{"key":24,"text":126,"correct":22},{"key":28,"text":151,"correct":26},"340",{"key":31,"text":153,"correct":22},"400",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},929614,"某拟建工程，房屋高度为57.6m，地下2层，地上15层，首层层高为6.0m，二层层高为4.5m，其余各层层高均为3.6m。采用现浇钢筋混凝土框架。剪力墙结构，抗震设防烈度为7度，丙类建筑，设计基本地震加速度为0.15g，Ⅲ类场地。混凝土强度等级采用C40（fc=19.1N／mm2）。在规定的水平力作用下结构总地震倾覆力矩 底层剪力墙承受的地震倾覆力矩 2.假定，该结构采用振型分解反应谱法进行多遇地震作用下的弹性分析，单向水平地震作用下不考虑偶然偏心影响的某框架柱轴力标准值：不考虑扭转耦联时X向地震作用下为5800kN，Y向地震作用下为6500kN；考虑扭转耦联时X向地震作用下为5300kN，Y向地震作用下为5700kN。试问，该框架柱考虑双向水平地震作用的轴力标准值（kN）与下列何项数值最为接近？（ ）",[158,160,162,164],{"key":20,"text":159,"correct":22},"7180",{"key":24,"text":161,"correct":26},"7260",{"key":28,"text":163,"correct":22},"8010",{"key":31,"text":165,"correct":22},"8160",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":20,"analysis":33},929615,"某拟建工程，房屋高度为57.6m，地下2层，地上15层，首层层高为6.0m，二层层高为4.5m，其余各层层高均为3.6m。采用现浇钢筋混凝土框架。剪力墙结构，抗震设防烈度为7度，丙类建筑，设计基本地震加速度为0.15g，Ⅲ类场地。混凝土强度等级采用C40（fc=19.1N／mm2）。在规定的水平力作用下结构总地震倾覆力矩 底层剪力墙承受的地震倾覆力矩 1.试问，该结构抗震构造措施所用的抗震等级为下列何项？（ ）",[170,172,174,176],{"key":20,"text":171,"correct":26},"框架一级，剪力墙一级",{"key":24,"text":173,"correct":22},"框架一级，剪力墙二级",{"key":28,"text":175,"correct":22},"框架二级，剪力墙二级",{"key":31,"text":177,"correct":22},"框架二级，剪力墙一级",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},929616,"某拟建的高度为59m的16层现浇钢筋混凝土框剪结构，质量和刚度沿高度分布比较均匀，对风荷载不敏感，其两种平面方案如图所示（单位m）。假设在如图所示的作用方向两种结构方案的基本自振周期相同。 2.当估算围护结构风荷载时，方案a和方案b相同高度迎风面中点处单位面积风荷载比值，最接近于（ ）。 提示：按《建筑结构荷载规范》（GB 50009—2012）解题。",[182,184,186,188],{"key":20,"text":183,"correct":22},"1.5∶1",{"key":24,"text":185,"correct":22},"1.15∶1",{"key":28,"text":187,"correct":26},"1∶1",{"key":31,"text":189,"correct":22},"1∶1.2",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":31,"analysis":33},929617,"某拟建的高度为59m的16层现浇钢筋混凝土框剪结构，质量和刚度沿高度分布比较均匀，对风荷载不敏感，其两种平面方案如图所示（单位m）。假设在如图所示的作用方向两种结构方案的基本自振周期相同。 1.当估算主体结构的风荷载效应时，方案a与方案b的风荷载标准值（kN\u002Fm2）之比，最接近于（ ）。 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）解题。",[194,195,197,198],{"key":20,"text":187,"correct":22},{"key":24,"text":196,"correct":22},"1∶1.15",{"key":28,"text":189,"correct":22},{"key":31,"text":185,"correct":26},{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":28,"analysis":33},929618,"某框架—核心筒结构底层一连梁如图所示，连梁截面bb=400mm，hb=1800mm，混凝土强度等级C35，（fc=16.7N\u002Fmm2），水平地震作用组合连梁剪力设计值V=840kN，当连梁中交叉暗撑与水平线夹角为α（sinα=0.66）时，交叉暗撑采用HRB400钢。交叉暗撑计算所需纵向钢筋最接近于（ ）。",[203,204,205,206],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":31,"analysis":33},929619,"某抗震等级为二级的高层框架结构，首层的梁柱中节点，横向左、右侧梁截面尺寸及纵向梁截面尺寸如图所示。梁柱混凝土强度等级为C30，fc=14.3MPa，ft=1.43MPa，as=as′=60mm。节点左侧梁端弯矩设计值 右侧梁端弯矩设计值 上柱底部考虑地震作用组合的轴向压力设计值N=3484.0kN，节点上下层柱反弯点之间的距离Hc=4.65m。 3.下列关于节点核心区的箍筋配置最合适的是（ ）。",[211,213,215,217],{"key":20,"text":212,"correct":22},"双向4肢φ8@100",{"key":24,"text":214,"correct":22},"双向4肢φ8@120",{"key":28,"text":216,"correct":22},"双向4肢φ8@150",{"key":31,"text":218,"correct":26},"双向4肢φ10@100",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":28,"analysis":33},929620,"某抗震等级为二级的高层框架结构，首层的梁柱中节点，横向左、右侧梁截面尺寸及纵向梁截面尺寸如图所示。梁柱混凝土强度等级为C30，fc=14.3MPa，ft=1.43MPa，as=as′=60mm。节点左侧梁端弯矩设计值 右侧梁端弯矩设计值 上柱底部考虑地震作用组合的轴向压力设计值N=3484.0kN，节点上下层柱反弯点之间的距离Hc=4.65m。 2.节点的容许剪力设计值[Vj]最接近于（ ）kN。",[223,225,227,229],{"key":20,"text":224,"correct":22},"1816.94",{"key":24,"text":226,"correct":22},"2059.20",{"key":28,"text":228,"correct":26},"2725.41",{"key":31,"text":230,"correct":22},"3088.80",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":33},929621,"某抗震等级为二级的高层框架结构，首层的梁柱中节点，横向左、右侧梁截面尺寸及纵向梁截面尺寸如图所示。梁柱混凝土强度等级为C30，fc=14.3MPa，ft=1.43MPa，as=as′=60mm。节点左侧梁端弯矩设计值 右侧梁端弯矩设计值 上柱底部考虑地震作用组合的轴向压力设计值N=3484.0kN，节点上下层柱反弯点之间的距离Hc=4.65m。 1.节点的剪力设计值Vj最接近于（ ）kN。",[235,237,239,241],{"key":20,"text":236,"correct":22},"973.52",{"key":24,"text":238,"correct":26},"1182.43",{"key":28,"text":240,"correct":22},"1414.96",{"key":31,"text":242,"correct":22},"1476.48",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":20,"analysis":33},929622,"某具有高层装配整体楼面的框架一剪力墙结构，抗震设防烈度8度，楼面横向宽度18m，在布置横向剪力墙时，下列间距符合规定的是( )。",[247,249,251,253],{"key":20,"text":248,"correct":26},"30m",{"key":24,"text":250,"correct":22},"40m",{"key":28,"text":252,"correct":22},"45m",{"key":31,"text":254,"correct":22},"54m",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":20,"analysis":33},929623,"某具有高层装配整体楼面的框架—剪力墙结构，抗震设防烈度8度，楼面横向宽度18m，在布置横向剪力墙时，下列间距符合规定的是（ ）。",[259,260,261,262],{"key":20,"text":248,"correct":26},{"key":24,"text":250,"correct":22},{"key":28,"text":252,"correct":22},{"key":31,"text":254,"correct":22},{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":31,"analysis":33},929624,"某矩形框筒，平面尺寸如图6-24所示，总高度102m，承受水平力q=20kN\u002Fm，可简化成双槽形截面，等效槽形截面如图4所示。角柱为L形、截面面积A3=6.41m2、形心坐标y=0.90m。槽形截面惯性矩为3056.5m4。计算图中底层3号柱所受的轴力N3最接近于( )kN。",[267,269,271,273],{"key":20,"text":268,"correct":22},"1564.9",{"key":24,"text":270,"correct":22},"1711.4",{"key":28,"text":272,"correct":22},"1956.2",{"key":31,"text":274,"correct":26},"2097.8",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":28,"analysis":33},929625,"某建造于大城市市区的28层公寓，采用钢筋混凝土剪力墙结构体系。平面为矩形，共6个开间，横向剪力墙间距为8.1m，其中间的剪力墙的计算简图如图所示。在风荷载(标准值)作用下，试采用近似分析方法(将两个墙肢视为一拉一压，且其合力作用在墙肢的中心线上)，估算每根连梁的平均支座弯矩设计值Mb最接近于( )kN·m。",[279,281,283,285],{"key":20,"text":280,"correct":22},"±114",{"key":24,"text":282,"correct":22},"±126",{"key":28,"text":284,"correct":26},"±160",{"key":31,"text":286,"correct":22},"±176",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":28,"analysis":33},929626,"某建造于大城市市区的28层公寓，采用钢筋混凝土剪力墙结构体系。平面为矩形，共6个开间，横向剪力墙间距为8.1m，其中间的剪力墙的计算简图如图6-35所示。在风荷载（标准值）作用下，试采用近似分析方法（将两个墙肢视为一拉一压，且其合力作用在墙肢的中心线上），估算每根连梁的平均支座弯矩设计值Mb最接近于（ ）kN·m。",[291,292,293,294],{"key":20,"text":280,"correct":22},{"key":24,"text":282,"correct":22},{"key":28,"text":284,"correct":26},{"key":31,"text":286,"correct":22},{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":31,"analysis":33},929627,"某建造于大城市市区的28层公寓，采用钢筋混凝土剪力墙结构体系。平面为矩形，共6个开间，横向剪力墙间距为8.1m，层高2.8m，房屋宽15.7m，地面粗糙度D类。混凝土强度等级为C30，纵向钢筋采用HRB335钢，箍筋采用HPB300钢。as=a s′=35mm。 2.当未考虑非结构构件影响折减系数时，该建筑物的横向自振周期T1最接近于（ ）s。",[299,301,303,305],{"key":20,"text":300,"correct":22},"3.4",{"key":24,"text":302,"correct":22},"2.8",{"key":28,"text":304,"correct":22},"2.2",{"key":31,"text":306,"correct":26},"0.97",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":24,"analysis":33},929628,"某建造于大城市市区的28层公寓，采用钢筋混凝土剪力墙结构体系。平面为矩形，共6个开间，横向剪力墙间距为8.1m，层高2.8m，房屋宽15.7m，地面粗糙度D类。混凝土强度等级为C30，纵向钢筋采用HRB335钢，箍筋采用HPB300钢。as=a s′=35mm。 1.工程所在场地的地基土的构成如表所示。 若有抗震要求时，确定其建筑场地类别为（ ）类。",[311,313,315,317],{"key":20,"text":312,"correct":22},"Ⅰ",{"key":24,"text":314,"correct":26},"Ⅱ",{"key":28,"text":316,"correct":22},"Ⅲ",{"key":31,"text":318,"correct":22},"Ⅳ",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":31,"analysis":33},929629,"某高度45m钢结构，建于抗震设防烈度8度区，地震加速度0.2g，设计分组为第一组，场地类别为Ⅲ类，结构基本周期为1.0s。则与结构基本周期相应的地震影响系数，最接近于（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"0.05479",{"key":24,"text":326,"correct":22},"0.0678",{"key":28,"text":328,"correct":22},"0.0780",{"key":31,"text":330,"correct":26},"0.08214",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":31,"analysis":33},929630,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 4.已知二层某连梁截面尺寸为250mm×600mm，ln=1100mm，抗震等级为二级，as=as’=35mm，箍筋采用HRB335级钢筋（fy=300N\u002Fmm2），连梁左、右端同时针方向考虑地震作用组合的弯矩设计值 重力荷载代表值作用下，按简支梁计算的连梁端截面剪力设计值Vgh=10kN。试问，该连梁满足《高层建筑混凝土结构技术规程》（JGJ 3—2010）抗震设计要求的最小箍筋配置（双肢箍）应取下列何项？（ ）",[335,337,339,341],{"key":20,"text":336,"correct":22},"Φ8@100",{"key":24,"text":338,"correct":22},"Φ10@100",{"key":28,"text":340,"correct":22},"Φ10@150",{"key":31,"text":342,"correct":26},"Φ12@100",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":28,"analysis":33},929631,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 3.已知首层墙肢2一端边缘构件截面配筋形式如图6-19所示，假定其抗震等级为一级，轴压比等于0.4，箍筋采用HRB335级钢筋（fy=300N\u002Fmm2），箍筋保护层厚度取10mm。试问，其边缘构件箍筋采用下列何项配置时方能满足规范、规程的最低构造要求？（ ）提示：1．按《建筑抗震设计规范》（GB 50011—2010）作答；2．不计入墙水平分布筋；3．假定不计入箍筋重叠部分。",[347,348,349,350],{"key":20,"text":336,"correct":22},{"key":24,"text":340,"correct":22},{"key":28,"text":338,"correct":26},{"key":31,"text":342,"correct":22},{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":28,"analysis":33},929632,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 2.墙肢1处在第三层时，计算表明其端部所设暗柱仅需按构造配筋，轴压比=0.5。试问，该墙肢端部暗柱的竖向钢筋最小配置数量应为下列何项时，才能满足规范、规程的最低抗震构造要求？（ ） 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。",[355,357,359,361],{"key":20,"text":356,"correct":22},"6Φ20",{"key":24,"text":358,"correct":22},"6Φ18",{"key":28,"text":360,"correct":26},"6Φ16",{"key":31,"text":362,"correct":22},"6Φ14",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":24,"analysis":33},929633,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 1.假定，首层墙肢1的抗震等级为二级，考虑地震组合的一组不利内力计算值Mw=360kN·m，Vw=185kN。试问，在满足规范剪力墙截面受剪承载力限值时，墙肢l底部截面组合的剪力设计值（kN）与下列何项数值最为接近？（ ） 提示：1．按《建筑抗震设计规范》（GB 50011—2010）作答；2．取hw0=hw计算。",[367,369,371,373],{"key":20,"text":368,"correct":22},"1400",{"key":24,"text":370,"correct":26},"1540",{"key":28,"text":372,"correct":22},"1840",{"key":31,"text":374,"correct":22},"2060",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":24,"analysis":33},929634,"某高层建筑有抗震设防的底层大空间剪力墙结构，转换层以上楼层层高2.7m，横向剪力墙有效截面面积Aw2=19.2m2；框支层层高3.6m，横向落地剪力墙有效截面面积Aw1=11.4m2，框支层全部柱总截面面积Ac=2.88m2，柱截面均为1200mm×1200mm，混凝土强度等级框支层为C40，上层C25。下列各项中上下层刚度比正确的是（ ）。",[379,381,383,385],{"key":20,"text":380,"correct":22},"γ=1.64",{"key":24,"text":382,"correct":26},"γ=1.81",{"key":28,"text":384,"correct":22},"γ=1.88",{"key":31,"text":386,"correct":22},"γ=1.96",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":24,"analysis":33},929635,"某高层建筑有抗震设防的底层大空间剪力墙结构，转换层以上楼层层高2.7m，横向剪力墙有效截面面积Aw2=19.2m2；框支层层高3.6m，横向落地剪力墙有效截面面积Aw1=11.4m2，框支层全部柱截面面积Ae=2.88m2，柱截面均为1200mm×1200mm，混凝土强度等级框支层为C40，上层C25。下列各项上下层刚度比正确的是( )。",[391,392,393,394],{"key":20,"text":380,"correct":22},{"key":24,"text":382,"correct":26},{"key":28,"text":384,"correct":22},{"key":31,"text":386,"correct":22},{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":20,"analysis":33},929636,"某高层钢筋混凝土框架一剪力墙结构，平面尺寸为22m×60m，为满足使用要求其长度方向未设温度缝，仅设一条上下贯通的后浇带。建筑物使用期间结构最高平均温度Tmax=30℃，最低平均温度Tmin=10℃，设计考虑后浇带的封闭温度为15～25℃。假定，对该结构进行均匀温度作用分析。试问，该结构最大温升工况的均匀温度作用标准值 （℃）和最大降温工况的均匀温度作用标准值",[399,401,403,405],{"key":20,"text":400,"correct":26},"（℃），与下列何项数值最为接近？（ ）[2014年真题]",{"key":24,"text":402,"correct":22},"提示：①不考虑混凝土收缩、徐变的影响；",{"key":28,"text":404,"correct":22},"②按《建筑结构荷载规范》（G50009—2012）作答。",{"key":31,"text":33,"correct":22},{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":33},929637,"某高层钢结构，按8度抗震设防。结构设中心支撑，支撑斜杆钢材采用Q345（fy=325N\u002Fmm2），构件横断面如图所示。则满足腹板宽厚比要求的腹板厚度t最接近于（ ）mm。 提示：按《高层民用建筑钢结构技术规程》（JGJ 99—98）设计。",[410,412,414,416],{"key":20,"text":411,"correct":26},"26",{"key":24,"text":413,"correct":22},"28",{"key":28,"text":415,"correct":22},"30",{"key":31,"text":417,"correct":22},"32",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},929638,"某高层钢结构，按8度抗震设防。结构设中心支撑，支撑斜杆钢材采用Q345(fy=325N\u002Fmm2)，构件横断面如图6-7所示。则满足腹板宽厚比要求的腹板厚度t最接近于( )mm。 提示：按《高层民用建筑钢结构技术规程》(JGJ99-98)设计。",[422,423,424,425],{"key":20,"text":411,"correct":26},{"key":24,"text":413,"correct":22},{"key":28,"text":415,"correct":22},{"key":31,"text":417,"correct":22},{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":24,"analysis":33},929639,"某钢筋混凝土圆形烟囱，如图所示，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第一组，场地类别为Ⅱ类，基本自振周期T1=1.25s，50年一遇的基本风压ω0=0.45kN／m2，地面粗糙度为B类，安全等级为二级。已知该烟囱基础顶面以上各节（共分6节，每节竖向高度10m）重力荷载代表值如下表所示。[2014年真题] 提示：按《烟囱设计规范》（GB 50051—2013）作答。 3.假定，仅考虑第一振型的情况下，对烟囱进行横风向风振验算。试问，下列何项判断符合规范要求？（ ） 提示：①烟囱坡度为2％； ②烟囱顶部风压高度变化系数为μH=1.71； ③该烟囱第1振型的临界风速υcr，1=15.5m／s。",[430,432,434,436],{"key":20,"text":431,"correct":22},"可不计算亚临界横风向共振荷载",{"key":24,"text":433,"correct":26},"应验算横风向共振响应",{"key":28,"text":435,"correct":22},"可不计算横风向共振荷载",{"key":31,"text":437,"correct":22},"以上均不正确",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":31,"analysis":33},929640,"某钢筋混凝土圆形烟囱，如图所示，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第一组，场地类别为Ⅱ类，基本自振周期T1=1.25s，50年一遇的基本风压ω0=0.45kN／m2，地面粗糙度为B类，安全等级为二级。已知该烟囱基础顶面以上各节（共分6节，每节竖向高度10m）重力荷载代表值如下表所示。[2014年真题] 提示：按《烟囱设计规范》（GB 50051—2013）作答。 2.．试问，烟囱最大竖向地震作用标准值（kN）与下列何项数值最为接近？（ ）",[442,444,446,448],{"key":20,"text":443,"correct":22},"650",{"key":24,"text":445,"correct":22},"870",{"key":28,"text":447,"correct":22},"1740",{"key":31,"text":372,"correct":26},{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":33},929641,"某钢筋混凝土圆形烟囱，如图所示，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第一组，场地类别为Ⅱ类，基本自振周期T1=1.25s，50年一遇的基本风压ω0=0.45kN／m2，地面粗糙度为B类，安全等级为二级。已知该烟囱基础顶面以上各节（共分6节，每节竖向高度10m）重力荷载代表值如下表所示。[2014年真题] 提示：按《烟囱设计规范》（GB 50051—2013）作答。 1.试问，烟囱根部的竖向地震作用标准值（kN）与下列何项数值最为接近？（ ）",[453,454,455,457],{"key":20,"text":443,"correct":26},{"key":24,"text":445,"correct":22},{"key":28,"text":456,"correct":22},"1000",{"key":31,"text":458,"correct":22},"1200",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":31,"analysis":33},929642,"某8层钢结构，建于抗震设防烈度8度区，地震加速度0.20g，设计分组为第一组，场地类别为Ⅲ类，结构基本周期为1.0s。则与结构基本周期相应的地震影响系数，最接近于( )。",[463,464,465,466],{"key":20,"text":324,"correct":22},{"key":24,"text":326,"correct":22},{"key":28,"text":328,"correct":22},{"key":31,"text":467,"correct":26},"0.08624",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":31,"analysis":33},929643,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 4.已知首层框架角柱EF截面尺寸为500mm×600mm，与其相连的首层顶边跨梁截面为250mm×650mm，假定该框架抗震等级为一级，该柱顺时针方向的组合弯矩设计值为：柱",[472,474,476,478],{"key":20,"text":473,"correct":22},"380",{"key":24,"text":475,"correct":22},"405",{"key":28,"text":477,"correct":22},"415",{"key":31,"text":479,"correct":26},"445",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":31,"analysis":33},929644,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 3.假定，框架梁CD截面尺寸为250mm×650mm，h0=590mm，根据抗震计算结果，其边支座柱边的梁端截面顶面配筋为6Φ25。试问，在满足抗震构造要求的条件下其底部最小配筋面积（mm2）与下列何项数值最为接近？（ ）",[484,486,488,490],{"key":20,"text":485,"correct":22},"645",{"key":24,"text":487,"correct":22},"884",{"key":28,"text":489,"correct":22},"893",{"key":31,"text":491,"correct":26},"1473",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":33},929645,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 2.已知二层顶某跨框架边梁A B，在地震及各荷载作用下梁B端截面所产生的弯矩标准值如下：永久荷载下MGk=-65kN·m；楼面活荷载下MQk=-20kN·m；风荷载下Mwk=±70kN·m；水平地震作用下MEhk=±260kN·m。试问，满足规范要求时，AB梁B端截面考虑地震作用组合的最不利组合弯矩设计值MB（kN·m）与下列何项数值最为接近？（ ）",[496,498,500,502],{"key":20,"text":497,"correct":26},"-430",{"key":24,"text":499,"correct":22},"-440",{"key":28,"text":501,"correct":22},"-530",{"key":31,"text":503,"correct":22},"-540",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":24,"analysis":33},929646,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 1.假定，该框架结构层侧向刚度无突变，底层屈服强度系数为0.45，第二层的楼层屈服强度系数为0.55，框架底层柱轴压比均不小于0.5。若不考虑箍筋配置的影响，试问，罕遇地震作用下按弹性方法计算的底层层间位移Δue（mm）不超过下列何值时，方能满足规范对结构薄弱层层间弹塑性位移的要求？（ ）",[508,510,512,514],{"key":20,"text":509,"correct":22},"47.5",{"key":24,"text":511,"correct":26},"50.5",{"key":28,"text":513,"correct":22},"53.5",{"key":31,"text":515,"correct":22},"96.0",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":24,"analysis":33},929647,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 4.若该框架为钢结构，结构的基本自振周期T1＝1.2s，结构阻尼比ζ＝0.035，其他数据不变，结构总水平地震作用标准值FEk最接近于（ ）kN。",[520,522,524,526],{"key":20,"text":521,"correct":22},"2413",{"key":24,"text":523,"correct":26},"2628",{"key":28,"text":525,"correct":22},"2839",{"key":31,"text":527,"correct":22},"3140",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":24,"analysis":33},929648,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 3.若已知结构总水平地震作用标准值FEk＝3126kN，顶部附加水平地震作用ΔF6=256kN，作用于G5处的地震作用标准值F5最接近于（ ）kN。",[532,534,536,538],{"key":20,"text":533,"correct":22},"565",{"key":24,"text":535,"correct":26},"697",{"key":28,"text":537,"correct":22},"756",{"key":31,"text":539,"correct":22},"914",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":24,"analysis":33},929649,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 2.若该框架为钢筋混凝土结构，结构的基本自振周期T1＝0.85s，总水平地震作用标准值FEk＝3304kN，作用于顶部附加水平地震作用标准值ΔF6最接近于（ ）kN。",[544,546,548,550],{"key":20,"text":545,"correct":22},"153",{"key":24,"text":547,"correct":26},"258",{"key":28,"text":549,"correct":22},"466",{"key":31,"text":551,"correct":22},"525",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":28,"analysis":33},929650,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 1.假定结构的基本自振周期T1＝0.65s，结构阻尼比ζ＝0.05。结构总水平地震作用标准值FEk最接近于（ ）kN。",[556,558,560,562],{"key":20,"text":557,"correct":22},"2492",{"key":24,"text":559,"correct":22},"3271",{"key":28,"text":561,"correct":26},"4217",{"key":31,"text":563,"correct":22},"4555",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":31,"analysis":33},929651,"某3层内框架砖房，四角设有构造柱，建筑平面、剖面如图所示。设防烈度7度，内框架混凝土强度等级C20，柱截面400mm×400mm，梁截面250mm×650mm，现浇混凝土楼、屋盖。砖强度等级MU10，砂浆强度等级一层为M10，二层为M7.5，三层为M5。外墙厚370mm，墙外缘距轴线120mm。山墙未设门窗，基础顶面标高-0.5000。已知各质点重力荷载代表值为G3=5300kN，G2=7100kN，G1=7500kN，各层的水平地震剪力设计值V1、V2、V3最接近于( )。",[568,570,572,574],{"key":20,"text":569,"correct":22},"1759kN；1449kN；921kN",{"key":24,"text":571,"correct":22},"1759kN；1441kN；711kN",{"key":28,"text":573,"correct":22},"1759kN；1371kN；711kN",{"key":31,"text":575,"correct":26},"1353kN；1125kN；718kN",[577,580,583,586,589,592],{"id":15,"name":578,"category":7,"favorite":579},"领导干部任职前廉政法规知识测试题",92,{"id":581,"name":582,"category":7,"favorite":15},595,"建筑结构与设备",{"id":584,"name":585,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":587,"name":588,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":590,"name":591,"category":7,"favorite":8},534,"BIM工程师",{"id":593,"name":591,"category":7,"favorite":8},535]