[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":584},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,21,50,1330,[13,34,44,56,67,79,87,99,111,120,132,140,152,164,176,188,200,212,224,236,247,259,271,283,291,303,315,323,335,347,359,367,379,388,400,412,424,436,448,460,468,480,492,504,516,528,540,548,560,572],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},929552,1,"单选题","在选择楼盖结构设计方案时，下列各项不可取的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","抗震设计时，不论板柱—剪力墙结构房屋有多高，顶层及地下一层的顶板，应采用现浇的肋形梁板结构",false,{"key":24,"text":25,"correct":22},"B","房屋高度超过50m时，框架—核心筒结构房屋的楼盖，应采用现浇楼盖结构，包括肋形梁板楼盖.双向密肋楼盖.压型钢板与混凝土的组合楼盖等",{"key":27,"text":28,"correct":29},"C","房屋高度不超过50m的部分框支剪力墙结构，其转换层也可采用装配整体式楼盖，但应有增加预制板之间的整体性一系列构造措施",true,{"key":31,"text":32,"correct":22},"D","房屋高度不超过50m的框架结构或剪力墙结构，允许采用装配式楼盖，并配以提高预制板之间的整体性措施","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},929553,"在选择楼盖结构设计方案时，下列各项不可取的是( )。",[38,40,42,43],{"key":20,"text":39,"correct":22},"抗震设计时，不论板柱一剪力墙结构房屋有多高，顶层及地下一层的顶板，应采用现浇的肋形梁板结构",{"key":24,"text":41,"correct":22},"房屋高度超过50m时，框架一核心筒结构房屋的楼盖，应采用现浇楼盖结构，包括肋形梁板楼盖.双向密肋楼盖.压型钢板与混凝土的组合楼盖等",{"key":27,"text":28,"correct":29},{"key":31,"text":32,"correct":22},{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":31,"analysis":33},929554,"在设计屋面结构时，下列说法不正确的是（ ）。",[48,50,52,54],{"key":20,"text":49,"correct":22},"根据《建筑结构荷载规范》（GB 50009—2012），不上人的屋面均布活荷载标准值0.5kN\u002Fm2中，不包括因屋面排水不畅或堵塞所引起的积水重",{"key":24,"text":51,"correct":22},"根据《建筑结构荷载规范》（GB 50009—2012），屋顶花园的均布活荷载标准值3.0kN\u002Fm2中，不包括土.石.花草等重量",{"key":27,"text":53,"correct":22},"屋面均布活荷载，不与雪荷载同时组合",{"key":31,"text":55,"correct":29},"当为斜屋面时，《建筑结构荷载规范》（GB 50009—2012）第5.3.1条，屋面均布活荷载标准值是以沿屋面斜坡面积衡量的",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":31,"analysis":33},929555,"在设计屋面结构时，下列说法不正确的是( )。",[60,62,64,65],{"key":20,"text":61,"correct":22},"根据《建筑结构荷载规范》(G B. 50009-2001)(2006年版)的规定，不上人的屋面均布活荷载标准值0.5kN\u002Fm2中，不包括因屋面排水不畅或堵塞所引起的积水重",{"key":24,"text":63,"correct":22},"根据《建筑结构荷载规范》(G50009-2001)(2006年版)的规定，屋顶花园的均布活荷载标准值3.0kN\u002Fm2中，不包括土.石.花草等重量",{"key":27,"text":53,"correct":22},{"key":31,"text":66,"correct":29},"当为斜屋面时，《建筑结构荷载规范》(G50009-2001)(2006年版)所提供的屋面均布活荷载标准值是以沿屋面斜坡面积衡量的",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":20,"analysis":33},929556,"在设防烈度为6度至9度地区内的乙类、丙类高层建筑，应进行抗震设计，其地震作用计算按下列哪种做法才符合《高层建筑混凝土结构技术规范》(JGJ3-2002、J186- 2002)的规定 ( )",[71,73,75,77],{"key":20,"text":72,"correct":29},"各抗震设防的高层建筑结构均应计算地震作用",{"key":24,"text":74,"correct":22},"6度设防时，Ⅰ～Ⅲ类场地上的建筑不必计算，Ⅳ类场地上的较高建筑及7度至9度设防的建筑应按本地区设防烈度计算",{"key":27,"text":76,"correct":22},"6度不必计算，7度至9度设防的建筑应按本地区设防烈度计算",{"key":31,"text":78,"correct":22},"6度设防时Ⅰ.Ⅱ类场地上的建筑不必计算，Ⅲ类和Ⅳ类场地上建筑及7度至9度设防的建筑应按本地区设防烈度计算",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":20,"analysis":33},929557,"在设防烈度为6度至9度地区内的乙类、丙类高层建筑，应进行抗震设计，其地震作用计算按下列哪种做法才符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）的规定？（ ）",[83,84,85,86],{"key":20,"text":72,"correct":29},{"key":24,"text":74,"correct":22},{"key":27,"text":76,"correct":22},{"key":31,"text":78,"correct":22},{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":31,"analysis":33},929558,"在某大城市市中心有一特重要的钢筋混凝土框架一核心筒结",[91,93,95,97],{"key":20,"text":92,"correct":22},"1.3",{"key":24,"text":94,"correct":22},"1.5",{"key":27,"text":96,"correct":22},"1.7",{"key":31,"text":98,"correct":29},"1.8",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":27,"analysis":33},929559,"在8度抗震区有一高21m的钢筋混凝土的框架结构裙房，与高120m的钢筋混凝土框架一剪力墙结构主楼之间，设防震缝一道。根据《高层建筑混凝土结构技术规范》(JGJ 3-2002、J186-2002)，该防震缝的最小宽度δ应为( )mm。",[103,105,107,109],{"key":20,"text":104,"correct":22},"70",{"key":24,"text":106,"correct":22},"77",{"key":27,"text":108,"correct":29},"110",{"key":31,"text":110,"correct":22},"539",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":27,"analysis":33},929560,"在8度抗震区有一高21m的钢筋混凝土的框架结构裙房，与高120m的钢筋混凝土框架—剪力墙结构主楼之间，设防震缝一道。该防震缝的最小宽度δ应为（ ）mm。",[115,116,117,119],{"key":20,"text":104,"correct":22},{"key":24,"text":106,"correct":22},{"key":27,"text":118,"correct":29},"140",{"key":31,"text":110,"correct":22},{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":24,"analysis":33},929561,"有一幢高层框架一剪力墙结构，层数为22层，高度80m，抗震设防烈度8度，Ⅲ类场地，设计地震分组为一组，总重力荷载代表值为∑Gi=286000kN，基本自振周期T1=1.43s，则采用底部剪力法计算底部剪力标准值FEk=( )kN。",[124,126,128,130],{"key":20,"text":125,"correct":22},"16159.1",{"key":24,"text":127,"correct":29},"13735.2",{"key":27,"text":129,"correct":22},"12349.5",{"key":31,"text":131,"correct":22},"10537",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":24,"analysis":33},929562,"有一幢高层框架—剪力墙结构，层数为22层，高度80m，抗震设防烈度8度，Ⅲ类场地，设计地震分组为一组，总重力荷载代表值为∑Gi=286000kN，基本自振周期T1=1.43s，则采用底部剪力法计算底部剪力标准值FEk=（ ）kN。",[136,137,138,139],{"key":20,"text":125,"correct":22},{"key":24,"text":127,"correct":29},{"key":27,"text":129,"correct":22},{"key":31,"text":131,"correct":22},{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":27,"analysis":33},929563,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 4.连梁每侧的腰筋配置最接近于（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":22},"4φ10",{"key":24,"text":147,"correct":22},"4φ8",{"key":27,"text":149,"correct":29},"4φ12",{"key":31,"text":151,"correct":22},"3φ10",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":31,"analysis":33},929564,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 3.连梁配置的箍筋最接近于（ ）。",[156,158,160,162],{"key":20,"text":157,"correct":22},"双肢φ8@110",{"key":24,"text":159,"correct":22},"双肢φ8@200",{"key":27,"text":161,"correct":22},"双肢φ8@150",{"key":31,"text":163,"correct":29},"双肢φ8@100",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":20,"analysis":33},929565,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 2.连梁的容许剪力设计值最接近于（ ）kN。",[168,170,172,174],{"key":20,"text":169,"correct":29},"349",{"key":24,"text":171,"correct":22},"387",{"key":27,"text":173,"correct":22},"402",{"key":31,"text":175,"correct":22},"465",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":27,"analysis":33},929566,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 1.连梁配置箍筋时的剪力设计值最接近于（ ）kN。",[180,182,184,186],{"key":20,"text":181,"correct":22},"150",{"key":24,"text":183,"correct":22},"165",{"key":27,"text":185,"correct":29},"180",{"key":31,"text":187,"correct":22},"195",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":27,"analysis":33},929567,"以下关于高层建筑混凝土结构设计与施工的4种观点： Ⅰ．分段搭设的悬挑脚手架，每段高度不得超过25m Ⅱ．大体积混凝土浇筑体的里表温差不宜大于25℃，混凝土浇筑表面与大气温差不宜大于20℃ Ⅲ．混合结构核心筒应先于钢框架或型钢混凝土框架施工，高差宜控制在4～8层，并应满足施工工序的穿插要求 Ⅳ．常温施工时，柱、墙体拆模混凝土强度不应低于1.2MPa 试问，针对上述观点是否符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）相关要求判断，下列何项正确？（ ）[2012年真题]",[192,194,196,198],{"key":20,"text":193,"correct":22},"Ⅰ.Ⅱ符合，Ⅲ.Ⅳ不符合",{"key":24,"text":195,"correct":22},"Ⅰ.Ⅲ符合，Ⅱ.Ⅳ不符合",{"key":27,"text":197,"correct":29},"Ⅱ.Ⅲ符合，Ⅰ.Ⅳ不符合",{"key":31,"text":199,"correct":22},"Ⅲ.Ⅳ符合，Ⅰ.Ⅱ不符合",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},929568,"一幢五层的商店建筑，其抗震设防烈度为8度(0.2g)，场地类别为Ⅲ类，设计地震分组为第一组。该建筑采用钢结构，结构基本自振周期T1=0.4s，阻尼比ζ=0.035。由此，根据图7可算得该钢结构的地震影响系数α=( )。",[204,206,208,210],{"key":20,"text":205,"correct":22},"0.20",{"key":24,"text":207,"correct":29},"0.18",{"key":27,"text":209,"correct":22},"0.16",{"key":31,"text":211,"correct":22},"0.15",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":24,"analysis":33},929569,"一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 4.若二层中柱截面600mm×600mm混凝土C30在重力荷载代表值作用下NG=2200kN，在水平地震作用下该柱的附加轴向力标准值为NEk=±150kN，柱混凝土保护层厚度为30mm，箍筋采用HPB235钢筋四肢，其加密区内的箍筋体积配箍率ρv不宜小于（ ）。",[216,218,220,222],{"key":20,"text":217,"correct":22},"0.6%",{"key":24,"text":219,"correct":29},"0.95%",{"key":27,"text":221,"correct":22},"1.0%",{"key":31,"text":223,"correct":22},"1.2%",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":31,"analysis":33},929570,"一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 3.假定建筑物各层的重力荷载代表值如图所示，且结构基本自振周期T1=1.0s。若采用底部剪力法进行地震作用计算时，结构总水平地震作用设计值FE最接近于（ ）kN。",[228,230,232,234],{"key":20,"text":229,"correct":22},"3800",{"key":24,"text":231,"correct":22},"4400",{"key":27,"text":233,"correct":22},"4900",{"key":31,"text":235,"correct":29},"5500",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":24,"analysis":33},929571,"一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 2.未考虑非结构构件刚度影响时的框架基本自振周期T1最接近于（ ）s。",[240,242,244,246],{"key":20,"text":241,"correct":22},"0.5",{"key":24,"text":243,"correct":29},"0.9",{"key":27,"text":245,"correct":22},"1.2",{"key":31,"text":96,"correct":22},{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":20,"analysis":33},929572,"一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 1.在重力荷载代表值作用下，已知三层横梁的支座弯矩如图所示。当考虑梁端塑性变形内力重分布而对梁端负弯矩进行调幅，并取调幅系数为0.8时，则边横梁的跨中弯矩设计值M最接近于（ ）kN·m。",[251,253,255,257],{"key":20,"text":252,"correct":29},"73.5",{"key":24,"text":254,"correct":22},"88",{"key":27,"text":256,"correct":22},"93",{"key":31,"text":258,"correct":22},"111",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":24,"analysis":33},929573,"一幢高度为99m的剪力墙结构(图)，其女儿墙高度h=2.0m，女儿墙中部到室外地面的高度H=100m。基本风压w0=0.5kN\u002Fm2，B类地面粗糙度。女儿墙底部由风荷载产生的弯矩标准值Mwk(kN·m\u002Fm)与下列 ( )项数值接近。",[263,265,267,269],{"key":20,"text":264,"correct":22},"2.1",{"key":24,"text":266,"correct":29},"2.7",{"key":27,"text":268,"correct":22},"3.5",{"key":31,"text":270,"correct":22},"4.1",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":31,"analysis":33},929574,"一幢高60m、按6度抗震设防、位于Ⅳ类场地的钢筋混凝土框架一剪力墙结构，在基本振型地震作用下，框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的50%。在进行结构的抗震设计时，正确的是( )。",[275,277,279,281],{"key":20,"text":276,"correct":22},"因6度抗震设防，可允许不进行截面的抗震验算，仅需对框架和剪力墙分别按四级和三级抗震等级考虑抗震构造措施",{"key":24,"text":278,"correct":22},"应进行截面的抗震验算，并同时对框架按四级.剪力墙按三级抗震等级考虑抗震构造措施",{"key":27,"text":280,"correct":22},"应进行截面的抗震验算，并同时对框架按三级.剪力墙按二级抗震等级考虑抗震构造措施",{"key":31,"text":282,"correct":29},"应进行截面的抗震验算，并同时对框架和剪力墙均按二级抗震等级考虑抗震构造措施",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":31,"analysis":33},929575,"一幢高60m、按6度抗震设防、位于Ⅳ类场地的钢筋混凝土框架—剪力墙结构，在基本振型地震作用下，框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的50%。在进行结构的抗震设计时，正确的是（ ）。",[287,288,289,290],{"key":20,"text":276,"correct":22},{"key":24,"text":278,"correct":22},{"key":27,"text":280,"correct":22},{"key":31,"text":282,"correct":29},{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":20,"analysis":33},929576,"一幢20层的高层建筑，采用钢筋混凝土结构。该建筑的抗震设防烈度为8度(0.3g)，场地类别为Ⅱ类，设计地震分组为第一组。该结构的第一自振周期T1=1.2s，阻尼比ζ=0.05，地震影响系数α最接近于( )。",[295,297,299,301],{"key":20,"text":296,"correct":29},"0.08",{"key":24,"text":298,"correct":22},"0.07",{"key":27,"text":300,"correct":22},"0.06",{"key":31,"text":302,"correct":22},"0.05",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":31,"analysis":33},929577,"一展览厅的圆弧形静定三铰拱，其跨度ι=25m，矢高f=4m(图)，在 C、 D、E处均作用着两个集中荷载Pgk及Pqk，即一是由永久荷载标准值产生的拱顶集中荷载Pgk=100kN，另一是由拱面活荷载标准值产生的拱顶集中荷载Pqk=50kN， 由此算得该拱底部拉杆的轴向拉力设计值NA=( )kN。",[307,309,311,313],{"key":20,"text":308,"correct":22},"495.8",{"key":24,"text":310,"correct":22},"560.55",{"key":27,"text":312,"correct":22},"585.25",{"key":31,"text":314,"correct":29},"593.75",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":31,"analysis":33},929578,"一展览厅的圆弧形静定三铰拱，其跨度l=25m，矢高f=4m（见图），在 C、 D、E处均作用着两个集中荷载Pgk及Pqk，即一是由永久荷载标准值产生的拱顶集中荷载Pgk=100kN，另一是由拱面活荷载标准值产生的拱顶集中荷载Pqk=50kN，由此算得该拱底部拉杆的轴向拉力设计值NA=（ ）kN。",[319,320,321,322],{"key":20,"text":308,"correct":22},{"key":24,"text":310,"correct":22},{"key":27,"text":312,"correct":22},{"key":31,"text":314,"correct":29},{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":24,"analysis":33},929579,"一商厦建筑的抗震设防烈度为8度（0.30g）。该建筑的入口处采用悬挑长度为17.5m的钢桁架（见图），桁架高度为2.5m。钢桁架节点上的重力荷载代表值Pgk=90kN。由此，可算得该桁架端部斜腹杆a仅由竖向地震作用产生的轴向力 =（ ）kN。",[327,329,331,333],{"key":20,"text":328,"correct":22},"50",{"key":24,"text":330,"correct":29},"76.4",{"key":27,"text":332,"correct":22},"80",{"key":31,"text":334,"correct":22},"100",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":20,"analysis":33},929580,"一商店建筑中有一挑出长度为8m的长悬挑梁，梁上作用着永久荷载标准值的线荷载gk=30kN\u002Fm，楼面活荷载标准值的线荷载qk=20kN\u002Fm(图6-9)。该建筑的抗震设防烈度为8度(0.30g)。由此可算得梁端A处的最大弯矩设计值MA=( )kN·m。 提示：计算时应对有无竖向地震作用，以及比较永久荷载效应控制的组合与可变荷载效应控制的组合，然后确定最大弯矩设计值MA。",[339,341,343,345],{"key":20,"text":340,"correct":29},"2048.0",{"key":24,"text":342,"correct":22},"1923.2",{"key":27,"text":344,"correct":22},"1800.0",{"key":31,"text":346,"correct":22},"1785.6",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":31,"analysis":33},929581,"一客车停车库的楼面结构平面如图所示，该结构采用单向板及主次梁结构，次梁的间距为4m，主梁（框架梁）的间距沿纵向为9m，沿横向为8m。次梁将楼面永久荷载及楼面活荷载以集中荷载传递给主梁见图6-21（b），当按《建筑结构荷载规范》（GB 50009—2012）规定考虑楼面活荷载折减系数时，则可算得次梁传给主梁的活荷载集中荷载标准值Pqk＝（ ）kN。",[351,353,355,357],{"key":20,"text":352,"correct":22},"144",{"key":24,"text":354,"correct":22},"120",{"key":27,"text":356,"correct":22},"90",{"key":31,"text":358,"correct":29},"86.4",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":31,"analysis":33},929582,"一客车停车库的楼面结构平面如图(a)所示，该结构采用单向板及主次梁结构，次梁的间距为4m，主梁(框架梁)的间距沿纵向为9m，沿横向为8m。次梁将楼面永久荷载及楼面活荷载以集中荷载传递给主梁(图(b))，当按《建筑结构荷载规范》(GB 50009-2001)(2006年版)规定考虑楼面活荷载折减系数时，则可算得次梁传给主梁的活荷载集中荷载标准值Pqk=( )kN。",[363,364,365,366],{"key":20,"text":352,"correct":22},{"key":24,"text":354,"correct":22},{"key":27,"text":356,"correct":22},{"key":31,"text":358,"correct":29},{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":27,"analysis":33},929583,"下列四种高层建筑结构布置正确的是（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":22},"框架结构体系，当矩形建筑平面的长边边长为短边的4倍时，主要承重框架宜顺长向布置，形成纵向布置方案，对抗侧力有利",{"key":24,"text":374,"correct":22},"框架—剪力墙结构体系，当矩形建筑平面的长边边长为短边的4倍时，顺长边方向布置的纵向剪力墙宜集中布置在房屋的纵向两尽端",{"key":27,"text":376,"correct":29},"不论采用哪种结构，在一个独立结构单元内，其结构的平面布置宜对称.刚度和承载力分布均匀",{"key":31,"text":378,"correct":22},"不论场地的地质情况如何，为了高层建筑的抗滑和抗倾覆需要，均宜设地下室",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":27,"analysis":33},929584,"下列四种高层建筑结构布置正确的是( )。",[383,384,386,387],{"key":20,"text":372,"correct":22},{"key":24,"text":385,"correct":22},"框架一剪力墙结构体系，当矩形建筑平面的长边边长为短边的4倍时，顺长边方向布置的纵向剪力墙宜集中布置在房屋的纵向两尽端",{"key":27,"text":376,"correct":29},{"key":31,"text":378,"correct":22},{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":31,"analysis":33},929585,"下列关于竖向地震作用的主张，其中何项不正确？（ ）[2011年真题]",[392,394,396,398],{"key":20,"text":393,"correct":22},"9度抗震设计的高层建筑应计算竖向地震作用",{"key":24,"text":395,"correct":22},"8度抗震设计时，跨度大于24m的结构应考虑竖向地震作用",{"key":27,"text":397,"correct":22},"8度抗震设计的带转换层高层结构中的转换构件应考虑竖向地震作用的影响",{"key":31,"text":399,"correct":29},"8度采用隔震设计的建筑结构，可不计竖向地震作用",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":27,"analysis":33},929586,"下列关于高层建筑混凝土结构的抗震性能优化设计的4种观点： Ⅰ．达到A级性能目标的结构在大震作用下仍处于基本弹性状态； Ⅱ．建筑结构抗震性能化设计的性能目标，应不低于《建筑抗震设计规范》（GB 50011—2010）规定的基本设防目标； Ⅲ．严重不规则的建筑结构，其结构抗震性能目标应为A级； Ⅳ．结构抗震性能目标应综合考虑抗震设防类别、设防烈度、场地条件、结构的特殊性、建造费用、震后损失和修复难易程度等各项因素选定。 试问，针对上述观点正确性的判断，下列何项正确？（ ）[2012年真题]",[404,406,408,410],{"key":20,"text":405,"correct":22},"Ⅰ.Ⅱ.Ⅲ正确，Ⅳ错误",{"key":24,"text":407,"correct":22},"Ⅱ.Ⅲ.Ⅳ正确，Ⅰ错误",{"key":27,"text":409,"correct":29},"Ⅰ.Ⅱ.Ⅳ正确，Ⅲ错误",{"key":31,"text":411,"correct":22},"Ⅰ.Ⅲ.Ⅳ正确，Ⅱ错误",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":27,"analysis":33},929587,"下列关于高层建筑钢筋混凝土结构有关抗震的一些观点，其中何项不正确？（ ）[2011年真题] 提示：不考虑楼板开洞影响，按《建筑抗震设计规范》（GB 50011—2010）作答。",[416,418,420,422],{"key":20,"text":417,"correct":22},"对于板柱—抗震墙结构，沿两个主轴方向穿过柱截面的板底两个方向钢筋的受拉承载力应满足该层楼板重力荷载代表值（8度时尚宜计入竖向地震）作用下的柱轴压力设计值",{"key":24,"text":419,"correct":22},"钢筋混凝土框架—剪力墙结构中的剪力墙两端（不包括洞口两侧）宜设置端柱或与另一方向的剪力墙相连",{"key":27,"text":421,"correct":29},"抗震设计的剪力墙应设置底部加强部位，当结构计算嵌固端位于地下一层底板时，底部加强部位的高度应从地下一层底板算起",{"key":31,"text":423,"correct":22},"钢筋混凝土结构地下室顶板作为上部结构的嵌固部位时，应避免在地下室顶板开大洞口。地下室顶板的厚度不宜小于180mm，若柱网内设置多个次梁时，可适当减小",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":33},929588,"下列关于高层混凝土结构的相关论述，何项观点不符合相关规范、规程要求？（ ）[2014年真题]",[428,430,432,434],{"key":20,"text":429,"correct":29},"房屋高度大于60m的高层建筑，设计时应按基本风压的1.1倍采用",{"key":24,"text":431,"correct":22},"无论采用何种结构体系，结构的平面和竖向布置宜使结构具有合理的刚度.质量和承载力分布，避免因局部突变和扭转效应而形成薄弱部位",{"key":27,"text":433,"correct":22},"钢筋混凝土高层建筑结构，在水平力作用下，只要结构的弹性等效侧向刚度和重力荷载之间的关系满足一定的限值，可不考虑重力二阶效应的不利影响",{"key":31,"text":435,"correct":22},"抗震设计时，钢筋混凝土柱轴压比中的轴向压力，采用地震作用组合的轴向压力设计值",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":24,"analysis":33},929589,"下列关于复杂高层建筑混凝土结构抗震设计的4种说法： Ⅰ．7度抗震设防时，地上转换结构构件可采用厚板结构； Ⅱ．7度、8度抗震设计时，层数和刚度相差悬殊的建筑不宜采用连体结构； Ⅲ．带加强层高层建筑结构在抗震设计时，仅需在加强层核心筒剪力墙处设置约束边缘构件； Ⅳ．多塔楼结构在抗震设计时，塔楼中与裙房相连的外围柱，从嵌固端至裙房屋面的高度范围内，柱纵筋的最小配筋率宜适当提高。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[440,442,444,446],{"key":20,"text":441,"correct":22},"Ⅳ正确，Ⅰ.Ⅱ.Ⅲ错误",{"key":24,"text":443,"correct":29},"Ⅱ正确，Ⅰ.Ⅲ.Ⅳ错误",{"key":27,"text":445,"correct":22},"Ⅰ正确，Ⅱ.Ⅲ.Ⅳ错误",{"key":31,"text":447,"correct":22},"Ⅰ.Ⅱ.Ⅲ.Ⅳ均错误",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":20,"analysis":33},929590,"位于设防烈度8度，Ⅲ类场地，高58m的丙类钢筋混凝土框架—剪力墙结构房屋。在重力荷载代表值，水平风荷载及水平地震作用下第四层边柱的轴向力标准值分别为NG=4200kN，Nw=1200kN，NEh=500kN；柱截面为600mm×800mm，混凝土C40，fc=19.1N\u002Fmm2。第四层层高3.60m，横梁高600mm。经计算知剪力墙部分承受的地震倾覆力矩大于结构总地震倾覆力矩的50%较多。则该柱轴压比验算结果正确的是（ ）。",[452,454,456,458],{"key":20,"text":453,"correct":29},"μN=0.621＜0.80，符合规程要求",{"key":24,"text":455,"correct":22},"μN=0.644＜0.75，符合规程要求",{"key":27,"text":457,"correct":22},"μN=0.657＜0.80，符合规程要求",{"key":31,"text":459,"correct":22},"μN=0.657＜0.85，符合规程要求",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":20,"analysis":33},929591,"位于设防烈度8度，Ⅲ类场地，高58m，丙类的钢筋混凝土框架一剪力墙结构房屋。在重力荷载代表值，水平风荷载及水平地震作用下第四层边柱的轴向力标准值分别为NG=4200kN，Nw=1200kN，nEb=500kN；柱截面为600mm×800mm，混凝土C40，fe=19.1N\u002F mm2。第四层层高3.60m，横梁高600mm。经计算知剪力墙部分承受的地震倾覆力矩大于结构总地震倾覆力矩的50%较多。则该柱轴压比验算结果正确的是( )。",[464,465,466,467],{"key":20,"text":453,"correct":29},{"key":24,"text":455,"correct":22},{"key":27,"text":457,"correct":22},{"key":31,"text":459,"correct":22},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":31,"analysis":33},929592,"位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地面以上有10层，总高40m，结构形式为钢筋混凝土框架结构。剖面和平面如图所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共12500kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共13050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为0.9s。该楼的结构布置、侧向刚度及质量等均对称、规则、均匀、属规则结构。 3.底层中柱A的竖向地震产生的轴向力标准值NEvk最接近于（ ）kN。",[472,474,476,478],{"key":20,"text":473,"correct":22},"702",{"key":24,"text":475,"correct":22},"707",{"key":27,"text":477,"correct":22},"1053",{"key":31,"text":479,"correct":29},"1061",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":20,"analysis":33},929593,"位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地面以上有10层，总高40m，结构形式为钢筋混凝土框架结构。剖面和平面如图所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共12500kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共13050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为0.9s。该楼的结构布置、侧向刚度及质量等均对称、规则、均匀、属规则结构。 2.第8层的竖向地震作用标准值Fv8k最接近于（ ）kN。",[484,486,488,490],{"key":20,"text":485,"correct":29},"3065",{"key":24,"text":487,"correct":22},"3303",{"key":27,"text":489,"correct":22},"3751",{"key":31,"text":491,"correct":22},"3985",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":24,"analysis":33},929594,"位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地面以上有10层，总高40m，结构形式为钢筋混凝土框架结构。剖面和平面如图所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共12500kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共13050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为0.9s。该楼的结构布置、侧向刚度及质量等均对称、规则、均匀、属规则结构。 1.结构的总竖向地震作用标准值FEvk最接近于（ ）kN。",[496,498,500,502],{"key":20,"text":497,"correct":22},"21060",{"key":24,"text":499,"correct":29},"21224",{"key":27,"text":501,"correct":22},"22862",{"key":31,"text":503,"correct":22},"23868",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":24,"analysis":33},929595,"图所示的框架为某框架—剪力墙结构中的一榀边框架，其抗震等级为二级，底部一、二层顶梁截面高度为700mm，梁顶与板顶平，柱截面为700mm×700mm。已知在重力荷载和地震作用下，柱BC的轴压比为0.75，节点B和柱BC未按“强柱弱梁”调整的组合弯矩设计值(kN·m)如图所示。[2012年真题] 提示：①对应于地震作用标准值，各层框架承担的剪力均不小于结构总剪力的20％； ②按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。 2.假定，角柱AD在重力荷载和地震作用组合下，柱上、下端按“强柱弱梁”要求调整后的弯矩设计值分别为 （同为顺时针方向）。试问，抗震设计时柱AD端部截面的剪力设计值（kN）与下列何项数值最为接近？（ ）",[508,510,512,514],{"key":20,"text":509,"correct":22},"175",{"key":24,"text":511,"correct":29},"200",{"key":27,"text":513,"correct":22},"225",{"key":31,"text":515,"correct":22},"250",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":24,"analysis":33},929596,"图所示的框架为某框架—剪力墙结构中的一榀边框架，其抗震等级为二级，底部一、二层顶梁截面高度为700mm，梁顶与板顶平，柱截面为700mm×700mm。已知在重力荷载和地震作用下，柱BC的轴压比为0.75，节点B和柱BC未按“强柱弱梁”调整的组合弯矩设计值(kN·m)如图所示。[2012年真题] 提示：①对应于地震作用标准值，各层框架承担的剪力均不小于结构总剪力的20％； ②按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。 1.试问，底层柱BC的纵向配筋计算时，考虑地震组合的弯矩设计值(kN·m)与下列何项数值最为接近？（ ）",[520,522,524,526],{"key":20,"text":521,"correct":22},"450",{"key":24,"text":523,"correct":29},"470",{"key":27,"text":525,"correct":22},"680",{"key":31,"text":527,"correct":22},"700",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":27,"analysis":33},929597,"图6-31(a)所示为一个8层钢筋混凝土框架结构的平面图。该建筑抗震烈度为8度，属于二级抗震等级。下列结构动力分析方法中，正确的是( )。",[532,534,536,538],{"key":20,"text":533,"correct":22},"只要作横向的平动振型抗震验算，因为纵向(y向)的抗侧刚度较弱",{"key":24,"text":535,"correct":22},"不仅要作横向的抗震验算，还要作纵向的抗震验算",{"key":27,"text":537,"correct":29},"除作x.y向的平动振型的抗震验算外，还要作扭转振型的耦联计算",{"key":31,"text":539,"correct":22},"该结构属于简单的纯框架，层数也不高，用基底剪力法计算其横向的水平地震力，并按各榀框架的抗侧刚度进行分配",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":20,"analysis":33},929598,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 4.条件同题（3），当柱轴压比μN=0.8，该柱在箍筋加密区的纵向钢筋和箍筋，下列各项中，最接近有关规范、规程最低构造要求的是（ ）。",[544,545,546,547],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":31,"analysis":33},929599,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 3.外周边框架底层某中柱，截面700mm×700mm，混凝土强度等级C50（fc=23.1N\u002Fmm2），内置Q345型钢（fa=295N\u002Fmm2），地震作用组合的柱轴向压力设计值N=19000kN，剪跨比λ=2.4。当要求柱轴压比μN≤0.8时，其采用的型钢截面面积应最接近于（ ）mm2。",[552,554,556,558],{"key":20,"text":553,"correct":22},"15000",{"key":24,"text":555,"correct":22},"19500",{"key":27,"text":557,"correct":22},"36000",{"key":31,"text":559,"correct":29},"45720",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":24,"analysis":33},929600,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 2.抗震设计时，在水平地震作用下，对应于地震作用标准值的结构底部总剪力计算值为8800kN；对于地震作用标准值且未经调整的各层框架总剪力中，24层最大，其计算值为1600kN。则各楼层框架的剪力经调整后最接近于（ ）kN。",[564,566,568,570],{"key":20,"text":565,"correct":22},"1500",{"key":24,"text":567,"correct":29},"1760",{"key":27,"text":569,"correct":22},"1920",{"key":31,"text":571,"correct":22},"2400",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":20,"analysis":33},929601,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 1.计算多遇地震作用时，该结构的水平地震作用影响系数α最接近于（ ）。",[576,578,580,582],{"key":20,"text":577,"correct":29},"0.0172",{"key":24,"text":579,"correct":22},"0.020",{"key":27,"text":581,"correct":22},"0.022",{"key":31,"text":583,"correct":22},"0.024",[585,588,591,594,597,600],{"id":15,"name":586,"category":7,"favorite":587},"领导干部任职前廉政法规知识测试题",92,{"id":589,"name":590,"category":7,"favorite":15},595,"建筑结构与设备",{"id":592,"name":593,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":595,"name":596,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":598,"name":599,"category":7,"favorite":8},534,"BIM工程师",{"id":601,"name":599,"category":7,"favorite":8},535]