[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,20,50,1330,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,270,282,294,306,318,330,342,354,366,378,386,398,410,422,434,446,458,470,482,490,502,514,526,538,550,562,574,586,598],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},929502,1,"单选题","某建筑场地位于8度抗震设防区，场地土层分布及土性如图5-18所示，其中粉土的黏粒含量百分率为14，拟建建筑基础埋深为1.5m，已知地面以下30m土层地质年代为第四纪全新世。试问，当地下水位在地表下5m时，按《建筑抗震设计规范》（GB 50011—2010）的规定，下述观点何项正确？（ ）",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","粉土层不液化，砂土层可不考虑液化影响",true,{"key":24,"text":25,"correct":26},"B","粉土层液化，砂土层可不考虑液化影响",false,{"key":28,"text":29,"correct":26},"C","粉土层不液化，砂土层需进一步判别液化影响",{"key":31,"text":32,"correct":26},"D","粉土层、砂土层均需进一步判别液化影响","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},929503,"在进行建筑地基基础设计时，关于所采用的荷载效应最不利组合与相应的抗力限值的下述内容，其中何项不正确？（ ）",[38,40,42,44],{"key":20,"text":39,"correct":26},"按地基承载力确定基础底面积时，传至基础的荷载效应按正常使用极限状态下荷载效应的标准组合，相应抗力采用地基承载力特征值",{"key":24,"text":41,"correct":26},"按单桩承载力确定桩数时，传至承台底面上的荷载效应按正常使用极限状态下荷载效应的标准组合，相应抗力采用单桩承载力特征值",{"key":28,"text":43,"correct":22},"计算地基变形时，传至基础底面上的荷载效应按正常使用极限状态下荷载效应的标准组合，相应限值应为相关规范规定的地基变形允许值",{"key":31,"text":45,"correct":26},"计算基础内力，确定其配筋和验算材料强度时，上部结构传来的荷载效应组合及相应的基底反力，应按承载力极限状态下荷载效应的基本组合，采用相应的分项系数",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},929504,"在同一非岩石地基上，建造相同埋置深度、相同基础底面宽度和相同基底附加压力的独立基础和条形基础，其地基最终变形量分别为s1和s2，则下列判断正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"s1＞s2",{"key":24,"text":53,"correct":26},"s1=s2",{"key":28,"text":55,"correct":22},"s1＜s2",{"key":31,"text":57,"correct":26},"不一定",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},929505,"试问复合地基的承载力特征值应按下述何种方法确定？（ ）",[62,64,66,68],{"key":20,"text":63,"correct":26},"桩间土的荷载试验结果",{"key":24,"text":65,"correct":26},"增强体的荷载试验结果",{"key":28,"text":67,"correct":22},"复合地基的荷载试验结果",{"key":31,"text":69,"correct":26},"本场地的工程地质勘察报告",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},929506,"对直径为1.65m的单桩嵌岩桩，当检验桩底有无空洞、破碎带、软弱夹层等不良地质现象时，应在柱底下的下述何种深度（m）范围进行？（ ）",[74,76,78,80],{"key":20,"text":75,"correct":26},"3",{"key":24,"text":77,"correct":22},"5",{"key":28,"text":79,"correct":26},"8",{"key":31,"text":81,"correct":26},"9",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},929507,"关于淤泥的天然含水量w和孔隙比e的数值，下列各项正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"w＞wL；e≥1.5",{"key":24,"text":89,"correct":26},"w＞wL；e≤1.5",{"key":28,"text":91,"correct":26},"w≥wP；e≥1.5",{"key":31,"text":93,"correct":26},"w＜wP；e≤1.5",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},929508,"某土样由试验测得重度为γ＝17.8kN\u002Fm3，含水量w＝16%，土粒的密度ds＝2.60，则下列选项中不正确的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"ρd＝1.53t\u002Fm3",{"key":24,"text":101,"correct":26},"ρsat＝1.94t\u002Fm3",{"key":28,"text":103,"correct":22},"n＝31.1%",{"key":31,"text":105,"correct":26},"γsat＝19.4kN\u002Fm3",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},929509,"某地基地质剖面如图所示，细砂层底面处的自重压力为（ ）kPa。",[110,112,114,116],{"key":20,"text":111,"correct":26},"42.05",{"key":24,"text":113,"correct":22},"47.05",{"key":28,"text":115,"correct":26},"62.05",{"key":31,"text":117,"correct":26},"82.05",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},929510,"某建筑物矩形基础底面尺寸2.4m×1.6m，埋深d＝2.0m，所受荷载设计值M＝100kN·m，F＝450kN，其他条件见图5-21，则基底最大、最小附加应力最接近于（ ）kPa。",[122,124,126,128],{"key":20,"text":123,"correct":26},"129.42；32.15",{"key":24,"text":125,"correct":22},"186.0；55.6",{"key":28,"text":127,"correct":26},"188.4；58",{"key":31,"text":129,"correct":26},"222.4；92",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},929511,"已知矩形基础受到建筑物传来的轴心荷载800kN，基础尺寸4m×2m，基础埋深2m，土的重度γ＝17.5kN\u002Fm3，则基底中心点以下2.0m处的附加应力pz最接近于（ ）kPa。",[134,136,138,140],{"key":20,"text":135,"correct":26},"12.6",{"key":24,"text":137,"correct":26},"21",{"key":28,"text":139,"correct":22},"50.4",{"key":31,"text":141,"correct":26},"84",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},929512,"已知某条形基础底宽b＝2.0m，埋深d＝1.5m，荷载合力的偏心距e＝0.05m。地基为粉质黏土，黏聚力ck＝10kPa，内摩擦角φk＝20°，地下水位距地表1.0m，地下水位以上土的重度γ＝18kN\u002Fm3，地下水位以下土的饱和重度γsat＝19.5kN\u002Fm3，则地基土的承载力特征值fa最接近于（ ）kPa。",[146,148,150,152],{"key":20,"text":147,"correct":26},"98.2",{"key":24,"text":149,"correct":26},"116.7",{"key":28,"text":151,"correct":22},"135.9",{"key":31,"text":153,"correct":26},"152.3",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},929513,"某建筑工程采用振动置换法碎石桩处理地基，碎石桩桩径为0.6m，等边三角形布桩，桩距1.5m。现场载荷试验测得桩间土承载力特征值为80kPa，根据《建筑地基处理技术规范》（JGJ 79—2012）计算得复合地基承载力标准值最接近于（ ）kPa。（桩土应力比取n=3）",[158,160,162,164],{"key":20,"text":159,"correct":26},"95",{"key":24,"text":161,"correct":22},"103",{"key":28,"text":163,"correct":26},"125",{"key":31,"text":165,"correct":26},"135",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":20,"analysis":33},929514,"某均质黏性土场地，土层地质情况为：qsk=15kPa，fsk=140kPa。拟采用高压喷射注浆法处理，正方形布桩，桩径为500mm，桩距为1.0m，桩长为12m。已知桩体抗压强度fcu=5.5MPa，桩间土承载力折减系数β=0.4，桩身强度折减系数η=0.33。 单桩承载力Ra最接近于（ ）kN。",[170,172,174,176],{"key":20,"text":171,"correct":22},"310",{"key":24,"text":173,"correct":26},"325",{"key":28,"text":175,"correct":26},"340",{"key":31,"text":177,"correct":26},"356",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},929515,"某均质黏性土场地，土层地质情况为：qsk=15kPa，fsk=140kPa。拟采用高压喷射注浆法处理，正方形布桩，桩径为500mm，桩距为1.0m，桩长为12m。已知桩体抗压强度fcu=5.5MPa，桩间土承载力折减系数β=0.4，桩身强度折减系数η=0.33。 复合地基承载力fspk不宜小于（ ）kPa。",[182,184,186,188],{"key":20,"text":183,"correct":22},"355",{"key":24,"text":185,"correct":26},"375",{"key":28,"text":187,"correct":26},"395",{"key":31,"text":189,"correct":26},"410",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":31,"analysis":33},929516,"在混凝土结构或结构构件设计中，常遇到的计算或验算有：Ⅰ．承载力计算；Ⅱ．倾覆、滑移验算；Ⅲ．裂缝宽度验算；Ⅳ．抗震设计计算。试问，在下列的计算或验算的组合中，何项全部不考虑结构构件的重要性系数?（ ）",[194,196,198,200],{"key":20,"text":195,"correct":26},"Ⅰ.Ⅲ.Ⅳ",{"key":24,"text":197,"correct":26},"Ⅱ.Ⅲ",{"key":28,"text":199,"correct":26},"Ⅱ.Ⅲ.Ⅳ",{"key":31,"text":201,"correct":22},"Ⅲ.Ⅳ",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},929517,"下列组合不包含非结构抗力物理量的是（ ）。 Ⅰ．受弯承载力Mu Ⅱ．受压承载力Nu Ⅲ．混凝土梁的刚度B Ⅳ．受剪承载力Vu Ⅴ．混凝土构件最大裂缝宽度wmax Ⅵ．裂缝出现时的弯矩Mcr Ⅶ．混凝土叠合构件纵筋应力ρsk",[206,208,210,212],{"key":20,"text":207,"correct":26},"Ⅰ.Ⅱ.Ⅲ.Ⅴ",{"key":24,"text":209,"correct":22},"Ⅰ.Ⅱ.Ⅳ.Ⅵ",{"key":28,"text":211,"correct":26},"Ⅰ.Ⅲ.Ⅳ.Ⅶ",{"key":31,"text":213,"correct":26},"Ⅲ.Ⅴ.Ⅵ.Ⅶ",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},929518,"下列全为不燃烧建筑材料的是( )。 Ⅰ．木材 Ⅱ．钢材 Ⅲ．塑料 Ⅳ．混凝土 Ⅴ．烧结多孔砖 Ⅵ．花岗岩",[218,220,222,224],{"key":20,"text":219,"correct":26},"Ⅰ.Ⅱ.Ⅲ.Ⅳ",{"key":24,"text":221,"correct":26},"Ⅰ.Ⅱ.Ⅳ.Ⅴ",{"key":28,"text":223,"correct":26},"Ⅱ.Ⅲ.Ⅴ.Ⅵ",{"key":31,"text":225,"correct":22},"Ⅱ.Ⅳ.Ⅴ.Ⅵ",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":33},929519,"下列关于建筑构件耐火极限的论述正确的是（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"当建筑构件具备失去稳定性，失去完整性，失去绝热性中任一条件时，即认为其达到耐火极限",{"key":24,"text":233,"correct":26},"承重构件由失去稳定性，或失去完整性判定是否达到耐火极限",{"key":28,"text":235,"correct":26},"分隔构件由失去稳定性，或失去隔热性判定是否达到耐火极限",{"key":31,"text":237,"correct":26},"承重分割构件由失去完整性，或失去隔热性判定是否达到耐火极限",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},929520,"下列关于荷载作用的描述哪项是正确的？（ ）",[242,244,246,248],{"key":20,"text":243,"correct":22},"地下室顶板消防车道区域的普通混凝土梁在进行裂缝控制验算和挠度验算时可不考虑消防车荷载",{"key":24,"text":245,"correct":26},"屋面均布活荷载可不与雪荷载和风荷载同时组合",{"key":28,"text":247,"correct":26},"对标准值大于4kN／m2的楼面结构的活荷载，其基本组合的荷载分项系数应取1.3",{"key":31,"text":249,"correct":26},"计算结构的温度作用效应时，温度作用标准值应根据50年重现期的月平均最高气温Tmax和月平均最低气温Tmin的差值计算",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":31,"analysis":33},929521,"下列关于地基基础设计的一些主张，其中何项是不正确的？（ ）",[254,256,258,260],{"key":20,"text":255,"correct":26},"场地内存在发震断裂时，如抗震防烈度小于8度，可忽略发震断裂错动对地面建筑的影响",{"key":24,"text":257,"correct":26},"对砌体房屋可不进行天然地基及基础的搞垮承载力验算",{"key":28,"text":259,"correct":26},"当高耸结构的高度不超过20m时，基础倾斜的允许值为0.008",{"key":31,"text":261,"correct":22},"高宽比大于4的高层建筑，基础底面与地基之间零应力区面积不应超过基础底面面积的15%",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},929522,"下列各项中，钢铁的重度γs与木材的重度γt之比最接近的范围是( )。",[266,268],{"key":20,"text":267,"correct":26},"γs\u002Fγt＞20",{"key":24,"text":269,"correct":22},"γs\u002Fγt=8.0～20",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":28,"analysis":33},929523,"下列各项中，( )不属于超过承载能力极限状态的情形。",[274,276,278,280],{"key":20,"text":275,"correct":26},"地基失稳",{"key":24,"text":277,"correct":26},"墙.柱压屈失稳",{"key":28,"text":279,"correct":22},"构件变形过大，超过规范规定的挠度或水平变位限值",{"key":31,"text":281,"correct":26},"结构作为刚体失去平衡，如挑梁的倾覆",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":28,"analysis":33},929524,"下列各项不属于偶然作用的是( )。",[286,288,290,292],{"key":20,"text":287,"correct":26},"罕遇地震",{"key":24,"text":289,"correct":26},"爆炸力.撞击力",{"key":28,"text":291,"correct":22},"施工检修荷载",{"key":31,"text":293,"correct":26},"龙卷风",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":31,"analysis":33},929525,"下列不属于超过正常使用极限状态的情形的是（ ）。",[298,300,302,304],{"key":20,"text":299,"correct":26},"影响正常使用的振动",{"key":24,"text":301,"correct":26},"影响正常使用或外观的变形",{"key":28,"text":303,"correct":26},"混凝土构件的裂缝宽度超过规范规定的限值",{"key":31,"text":305,"correct":22},"结构构件或连接因过度变形而不适于继续承载",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":31,"analysis":33},929526,"下列（ ）不是影响结构抗力的主要因素。",[310,312,314,316],{"key":20,"text":311,"correct":26},"材料性能的不定性",{"key":24,"text":313,"correct":26},"几何参数的不定性",{"key":28,"text":315,"correct":26},"计算模式的不定性",{"key":31,"text":317,"correct":22},"结构的作用或荷载的不定性",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},929527,"如果所设计的民用建筑的房间不包括在《建筑结构荷载规范》(GB 50009-2001)(2006年版)表4.1.1之内，但调查发现该房间有可能活动的人很集中，有时很挤或有较重的设备，则楼面均布活荷载标准值(kN\u002Fm2)比较合适的取值范围是( )。",[322,324,326,328],{"key":20,"text":323,"correct":26},"2.5～3.0",{"key":24,"text":325,"correct":22},"3.5～4.0",{"key":28,"text":327,"correct":26},"4.5～5.5",{"key":31,"text":329,"correct":26},"6.0～7.0",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":28,"analysis":33},929528,"普通的钢筋混凝土的重度γc与砖砌体的重度γm之比（重度指单位体积的重力，俗称自重）的范围是（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":26},"γc\u002Fγm＜1.1",{"key":24,"text":337,"correct":26},"γc\u002Fγm=1.1～1.25",{"key":28,"text":339,"correct":22},"γc\u002Fγm=1.25～1.40",{"key":31,"text":341,"correct":26},"γc\u002Fγm＞1.4",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":24,"analysis":33},929529,"某住宅用户进行二次装修，地面采用20mm水泥砂浆，然后在上面铺10mm厚大理石；而下家顶棚为V形钢龙骨吊顶，二层9mm纸面石膏板，无保温层；则增加楼面自重与楼面活荷载标准值的比值为（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":26},"0.35",{"key":24,"text":349,"correct":22},"0.44",{"key":28,"text":351,"correct":26},"0.50",{"key":31,"text":353,"correct":26},"0.59",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":24,"analysis":33},929530,"某一层吊车的两跨厂房，每跨厂房各设有3台A5工作级别的吊车。试问，通常情况下，进行该两跨厂房的每个排架计算时，参与组合的多台吊车的水平荷载标准值的折减系数应取下列何项数值？（ ）[2012年真题]",[358,360,362,364],{"key":20,"text":359,"correct":26},"0.95",{"key":24,"text":361,"correct":22},"0.9",{"key":28,"text":363,"correct":26},"0.85",{"key":31,"text":365,"correct":26},"0.8",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":28,"analysis":33},929531,"某框架结构钢筋混凝土办公楼，安全等级为二级，梁板布置如图所示。框架的抗震等级为三级，混凝土强度等级为C30，梁板均采用HRB400级钢筋。板面恒载标准值5.0kN／m2（含板自重），活荷载标准值2.0kN／m2，梁上恒荷载标准值10.0kN／m（含梁及梁上墙自重）。试问，配筋设计时，次梁L1上均布线荷载的组合设计值q（kN／m），与下列何项数值最为接近？（ ）[2014年真题] 提示：荷载传递按单向板考虑。",[370,372,374,376],{"key":20,"text":371,"correct":26},"37",{"key":24,"text":373,"correct":26},"38",{"key":28,"text":375,"correct":22},"39",{"key":31,"text":377,"correct":26},"40",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":24,"analysis":33},929532,"某房间有可能活动的人很集中，有时很挤或有较重的设备，则楼面均布活荷载标准值（kN\u002Fm2）比较合适的取值范围是（ ）。",[382,383,384,385],{"key":20,"text":323,"correct":26},{"key":24,"text":325,"correct":22},{"key":28,"text":327,"correct":26},{"key":31,"text":329,"correct":26},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":31,"analysis":33},929533,"某多层钢筋混凝土框架结构，房屋高度20m，混凝土强度等级C40，抗震设防烈度8度，设计基本地震加速度0.30g，抗震设防类别为标准设防类，建筑场地类别Ⅱ类。拟进行隔震设计，水平向减震系数为0.35，下列关于隔震设计的叙述，其中何项是正确的？（ ）",[390,392,394,396],{"key":20,"text":391,"correct":26},"隔震层以上各楼层的水平地震剪力可不符合本地区设防烈度的最小地震剪力系数的规定",{"key":24,"text":393,"correct":26},"隔震层下的地基基础的抗震验算按本地区抗震设防烈度进行，抗液化措施应按提高一个液化等级确定",{"key":28,"text":395,"correct":26},"隔震层以上的结构，水平地震作用应按7度（0.15g）计算，并应进行竖向地震作用的计算",{"key":31,"text":397,"correct":22},"隔震层以上的结构，框架抗震等级可定为三级，当未采取有利于提高轴压比限值的构造措施时，剪跨比大于2的柱的轴压比限值为0.75",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":28,"analysis":33},929534,"关于正常使用极限状态下荷载效应组合设计值S的表达式，下列叙述不正确的是( )。",[402,404,406,408],{"key":20,"text":403,"correct":26},"所有组合的第一项，即永久荷载效应采用标准值效应",{"key":24,"text":405,"correct":26},"对于标准组合，除可变荷载效应最大的取标准值以外，其余均采用可变荷载效应的组合值",{"key":28,"text":407,"correct":22},"对于频遇组合，可变荷载效应采用荷载的频遇值效应",{"key":31,"text":409,"correct":26},"对于准永久组合，可变荷载效应采用荷载的准永久值效应",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":31,"analysis":33},929535,"关于屋面活荷载的规定，下列叙述不正确的是( )。",[414,416,418,420],{"key":20,"text":415,"correct":26},"屋面均布活荷载，不应与雪荷载同时组合",{"key":24,"text":417,"correct":26},"不上人的屋面，当施工或维修荷载较大时，应按实际情况采用；不同结构应按有关规范规定，将标准值0.5kN\u002Fm2作0.2kN\u002Fm2的增减",{"key":28,"text":419,"correct":26},"上人的屋面，当兼作其他用途时，应按相应楼面活荷载采用",{"key":31,"text":421,"correct":22},"对于因屋面排水不畅.堵塞等引起的积水荷载，应采取加固措施加以防止",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":31,"analysis":33},929536,"关于结构承载能力极限状态基本组合中的可变荷载效应控制的组合设计表达式，即《建筑结构可靠度设计统一标准》(GB 50068-2001)式(7.0.2-1)或式(7.0.2-3)，下列叙述错误的是( )。",[426,428,430,432],{"key":20,"text":427,"correct":26},"永久荷载分项系数&gamma; G，当其对结构不利时应取1.2，有利时不应大于1.0(挑梁抗倾覆验算取0.8)",{"key":24,"text":429,"correct":26},"可变荷载分项系数&gamma;Q1和&gamma;Qi当其对结构不利时，一般应取1.4(对标准值大于4kN\u002Fm2的工业房屋楼面活荷载应取1.3)，有利时应取0",{"key":28,"text":431,"correct":26},"&psi;i为第i个可变荷载的组合值系数，其值不应大于1，并由荷载规范按不同荷载给出",{"key":31,"text":433,"correct":22},"&psi;为框.排架的简化设计表达式中采用的荷载组合系数，当有风荷载参与组合时取&psi;=0.9",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":20,"analysis":33},929537,"关于建筑抗震性能化设计的以下说法： Ⅰ．确定的性能目标不应低于“小震不坏、中震可修、大震不倒”的基本性能设计目标； Ⅱ．当构件的承载力明显提高时，相应的延性构造可适当降低； Ⅲ．当抗震设防烈度为7度设计基本地震加速度为0.15g时，多遇地震、设防地震、罕遇地震的地震影响系数最大值分别为0.12、0.34、0.72； Ⅳ．针对具体工程的需要，可以对整个结构也可以对某些部位或关键构件，确定预期的性能目标。 试问，针对上述说法正确性的判断，下列何项正确？（ ）",[438,440,442,444],{"key":20,"text":439,"correct":22},"Ⅰ.Ⅱ.Ⅲ.Ⅳ均正确",{"key":24,"text":441,"correct":26},"Ⅰ.Ⅱ.Ⅲ正确，Ⅳ错误",{"key":28,"text":443,"correct":26},"Ⅱ.Ⅲ.Ⅳ正确，Ⅰ错误",{"key":31,"text":445,"correct":26},"Ⅰ.Ⅱ.Ⅳ正确，Ⅲ错误",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":24,"analysis":33},929538,"关于混凝土高温性能，下列论述不正确的是（ ）。",[450,452,454,456],{"key":20,"text":451,"correct":26},"混凝土抗压强度300℃以上，随温度升高呈直线下降，600℃时降低50%，800℃时降低80%",{"key":24,"text":453,"correct":22},"抗拉强度高温时下降情况几乎同抗压强度",{"key":28,"text":455,"correct":26},"弹性模量50～200℃下降较明显，200～400℃下降缓慢，400～600℃下降更平缓",{"key":31,"text":457,"correct":26},"火灾中混凝土的爆裂使承载力迅速降低",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":31,"analysis":33},929539,"关于荷载代表值的概念，下列叙述错误的是( )。",[462,464,466,468],{"key":20,"text":463,"correct":26},"永久荷载标准值相当于其概率分布的0.5分位值",{"key":24,"text":465,"correct":26},"楼面活荷载标准值相当于设计基准期最大荷载平均值μqt加α倍标准差σqt",{"key":28,"text":467,"correct":26},"对住宅.办公楼楼面活荷载，荷载准永久值相当于取其设计基准期任意时点荷载概率分布的0.5分位值",{"key":31,"text":469,"correct":22},"可变荷载的荷载频遇值相当于取其设计基准期任意时点荷载概率分布的0.1分位值",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":31,"analysis":33},929540,"关于钢材高温性能，下列叙述不正确的是( )。",[474,476,478,480],{"key":20,"text":475,"correct":26},"低碳钢500℃时约为常温强度的1\u002F2，600℃约为1\u002F3",{"key":24,"text":477,"correct":26},"高强钢丝350℃时约为常温强度的1\u002F2，400℃约为1\u002F3",{"key":28,"text":479,"correct":26},"低碳钢300～350℃时，普通低合金钢400～450℃时，钢材徐变增大",{"key":31,"text":481,"correct":22},"冷加工钢筋高温性能和低碳钢相似",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":31,"analysis":33},929541,"度区某竖向规则的抗震墙结构如图1-1所示，房屋高度为90m，抗震设防类别为标准设防类。试问，下列四种经调整后的墙肢组合弯矩设计值简图，哪一种相对准确？（ ） 提示：根据《建筑抗震设计规范》（GB 50011—2010）作答。",[486,487,488,489],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":31,"analysis":33},929542,"按我国现行规范的规定，试判断下列说法中何项不妥？（ ）",[494,496,498,500],{"key":20,"text":495,"correct":26},"材料强度标准值的保证率为95%",{"key":24,"text":497,"correct":26},"永久荷载的标准值的保证率一般为95%",{"key":28,"text":499,"correct":26},"活荷载的准永久值的保证率为50%",{"key":31,"text":501,"correct":22},"活荷载的频遇值的保证率为95%",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":31,"analysis":33},929543,"《混凝土结构设计规范》(GB 50010-2002)规定，对用作预应力筋的钢丝、钢绞线和热处理钢筋，其抗拉强度设计值fpy=fpyk\u002Fγs，预应力钢筋材料性能分项系数γs=( )。",[506,508,510,512],{"key":20,"text":507,"correct":26},"1.05",{"key":24,"text":509,"correct":26},"1.10",{"key":28,"text":511,"correct":26},"1.15",{"key":31,"text":513,"correct":22},"1.20",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":31,"analysis":33},929544,"在结构设计的分项系数表达式中，针对承载能力和正常使用极限状态的设计要求应采用不同的荷载代表值。下列关于荷载代表值的规定正确的是（ ）。",[518,520,522,524],{"key":20,"text":519,"correct":26},"永久荷载和可变荷载均应采用荷载的标准值.组合值.频遇值或准永久值作为代表值",{"key":24,"text":521,"correct":26},"永久荷载应采用标准值.组合值，可变荷载应采用组合值.频遇值或准永久值作为代表值",{"key":28,"text":523,"correct":26},"永久荷载应采用标准值.频遇值，可变荷载应采用标准值.组合值或准永久值作为代表值",{"key":31,"text":525,"correct":22},"永久荷载应采用标准值，可变荷载应采用标准值.组合值.频遇值或准永久值作为代表值",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":31,"analysis":33},929545,"下列不属于永久荷载作用的是（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":26},"结构自重",{"key":24,"text":533,"correct":26},"土压力",{"key":28,"text":535,"correct":26},"预应力",{"key":31,"text":537,"correct":22},"温度作用",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":20,"analysis":33},929546,"关于设计基准期和设计使用年限的概念，下列叙述错误的是（ ）。",[542,544,546,548],{"key":20,"text":543,"correct":22},"可靠度指结构在规定的时间内，在规定的条件下完成预定功能的概率。其中，规定的时间指设计基准期",{"key":24,"text":545,"correct":26},"设计基准期是为确定可变作用及与时间有关的材料性能等取值而选用的时间参数，设计基准期为50年",{"key":28,"text":547,"correct":26},"设计使用年限是设计规定的结构或构件不需要进行大修即可按其预定的目的使用的时期",{"key":31,"text":549,"correct":26},"设计使用年限按1.2.3.4类分别采用5年.25年.50年.100年",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":28,"analysis":33},929547,"关于建立承载能力极限状态偶然组合设计表达式的原则，下列叙述不正确的是（ ）。",[554,556,558,560],{"key":20,"text":555,"correct":26},"只考虑一种偶然作用与其他荷载相组合",{"key":24,"text":557,"correct":26},"偶然作用的代表值不乘以分项系数",{"key":28,"text":559,"correct":22},"与偶然作用同时出现的可变荷载，应根据观测资料和工程经验采用适当的代表值，如组合值等",{"key":31,"text":561,"correct":26},"荷载与抗力分项系数，可根据结构可靠度分析或工程经验确定，应符合专门规范的规定",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":28,"analysis":33},929548,"关于对设计地震分组的下列的一些解释，其中何项较为符合规范编制中的抗震设防决策？（ ）",[566,568,570,572],{"key":20,"text":567,"correct":26},"是按实际地震的震级大小分为三组",{"key":24,"text":569,"correct":26},"是按场地剪切波速和覆盖层厚度分为三组",{"key":28,"text":571,"correct":22},"是按地震动反应谱特征周期和加速衰减影响的区域分为三组",{"key":31,"text":573,"correct":26},"是按震源机制和结构自振周期分为三组",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":24,"analysis":33},929549,"关于材料和岩土性能的试验值，下列叙述正确的是（ ）。",[578,580,582,584],{"key":20,"text":579,"correct":26},"材料和岩土的强度.变形模量.内摩擦角等物理力学性能，可根据试验.理论计算或经验确定",{"key":24,"text":581,"correct":22},"结构中材料性能的不定性，应由标准试件材料性能的不定性和换算系数或函数的不定性两部分组成",{"key":28,"text":583,"correct":26},"材料性能宜采用随机变量模型，各统计参数和概率分布函数，应以试验为基础用参数估计和假设检验确定。检验的显著水平可采用0.01",{"key":31,"text":585,"correct":26},"材料强度的概率分布宜采用极值Ⅰ型分布",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":24,"analysis":33},929550,"关于材料的高温性能，下列叙述错误的是（ ）。",[590,592,594,596],{"key":20,"text":591,"correct":26},"建筑材料燃烧性能分为：A不燃性，B1难燃性，B2可燃性，B3易燃性",{"key":24,"text":593,"correct":22},"钢材属不燃性材料，一定应力下，在高温时随时间增加不会发生缓慢变形",{"key":28,"text":595,"correct":26},"混凝土是一种耐火性良好的材料，300℃以下，抗压强度基本不变",{"key":31,"text":597,"correct":26},"黏土砖耐火性能好，240mm厚承重墙可耐火5h（小时）以上",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":28,"analysis":33},929551,"某项目周边建筑的情况如图所示，试问该项目风荷载计算时所需的地面粗糙度类别，选取下列何项符合规范要求？（ ） 提示：按《建筑结构荷载规范》（GB 50009—2012）条文说明作答。",[602,604,606,608],{"key":20,"text":603,"correct":26},"A类",{"key":24,"text":605,"correct":26},"B类",{"key":28,"text":607,"correct":22},"C类",{"key":31,"text":609,"correct":26},"D类",[611,614,617,620,623,626],{"id":15,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":15},595,"建筑结构与设备",{"id":618,"name":619,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":621,"name":622,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":624,"name":625,"category":7,"favorite":8},534,"BIM工程师",{"id":627,"name":625,"category":7,"favorite":8},535]