[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":592},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,2,50,1330,[13,34,46,58,70,78,90,102,114,126,138,150,161,173,185,197,208,220,232,243,255,266,277,289,301,313,323,335,347,359,371,379,391,403,413,421,433,445,457,469,481,493,505,513,525,536,544,556,568,580],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},928602,1,"单选题","某简支梁计算跨度l0＝6.9m，截面尺寸b×h＝250mm×650mm，混凝土为C30，钢筋为HRB335级。该梁承受均布恒载标准值（包括梁自重）gk＝16.20kN\u002Fm及均布活载标准值qk＝8.50kN\u002Fm，活荷载准永久系数取为ψq=0.4。梁跨中下部配有纵向受拉钢筋3Φ20（As＝941mm2），梁的混凝土保护层厚度c＝25mm。 2.已知As＝941mm2，αE＝7.14，γ′f＝0，ftk＝2.01N\u002Fmm2，Es=2.0×105N\u002Fmm2；假定σs＝285N\u002Fmm2，则该梁的短期刚度Bs最接近于（ ）N\u002Fmm2。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","5.12×1013",true,{"key":24,"text":25,"correct":26},"B","5.25×1013",false,{"key":28,"text":29,"correct":26},"C","5.30×1013",{"key":31,"text":32,"correct":26},"D","5.60×1013","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},928603,"某简支梁计算跨度l0＝6.9m，截面尺寸b×h＝250mm×650mm，混凝土为C30，钢筋为HRB335级。该梁承受均布恒载标准值（包括梁自重）gk＝16.20kN\u002Fm及均布活载标准值qk＝8.50kN\u002Fm，活荷载准永久系数取为ψq=0.4。梁跨中下部配有纵向受拉钢筋3Φ20（As＝941mm2），梁的混凝土保护层厚度c＝25mm。 1.跨中截面在荷载效应的标准组合作用下，纵向受拉钢筋的应力σs最接近于（ ）N\u002Fmm2。",[38,40,42,44],{"key":20,"text":39,"correct":22},"232",{"key":24,"text":41,"correct":26},"293",{"key":28,"text":43,"correct":26},"310",{"key":31,"text":45,"correct":26},"330",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},928604,"某混凝土构件局部受压情况如图所示，局部受压范围无孔洞、凹槽，并忽略边距的影响，混凝土强度等级为C25，安全等级为二级。[2013年真题] 假定，局部受压作用尺寸a=300mm，b=200mm。试问，进行混凝土局部受压验算时，其计算底面积Ab（mm2）与下列何项数值最为接近？（ ）",[50,52,54,56],{"key":20,"text":51,"correct":26},"300000",{"key":24,"text":53,"correct":22},"420000",{"key":28,"text":55,"correct":26},"560000",{"key":31,"text":57,"correct":26},"720000",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},928605,"某混凝土构件局部受压情况如图所示，局部受压范围无孔洞、凹槽，并忽略边距的影响，混凝土强度等级为C25，安全等级为二级。[2013年真题] 假定，局部受压面积a×b=400mm×250mm，局部受压计算底面积Ab=675000mm2，局部受压区配置焊接钢筋网片l2×l1=600mm×400mm，其中心与F1重合，钢筋直径为φ6（HPB300），钢筋网片单层钢筋n1=7（沿l1方向）及n2=5（沿l2方向），间距s=70mm。试问，局部受压承载力设计值（kN）应与下列何项数值最为接近？（ ）",[62,64,66,68],{"key":20,"text":63,"correct":26},"3500",{"key":24,"text":65,"correct":22},"4200",{"key":28,"text":67,"correct":26},"4800",{"key":31,"text":69,"correct":26},"5300",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},928606,"某混凝土构件局部受压情况如图所示，局部受压范围无孔洞、凹槽，并忽略边距的影响，混凝土强度等级为C25，安全等级为二级。[2013年真题] 假定，局部受压面积a×b=400mm×250mm，局部受压计算底面积Ab=675000mm2，局部受压区配置焊接钢筋网片l2×l1=600mm×400mm，其中心与F1重合，钢筋直径为6（HPB300），钢筋网片单层钢筋n1=7（沿l1方向）及n2=5（沿l2方向），间距s=70mm。试问，局部受压承载力设计值（kN）应与下列何项数值最为接近？（ ）",[74,75,76,77],{"key":20,"text":63,"correct":22},{"key":24,"text":65,"correct":26},{"key":28,"text":67,"correct":26},{"key":31,"text":69,"correct":26},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":28,"analysis":33},928607,"某混凝土单筋矩形截面简支梁，截面尺寸和配筋如图所示，采用C30混凝土，HRB335纵筋，环境类别为二a类。 2.关于图的截面配筋构造，下列说法正确的是（ ）。",[82,84,86,88],{"key":20,"text":83,"correct":26},"配筋构造正确，符合《混凝土结构设计规范》（GB 50010—2010）规定",{"key":24,"text":85,"correct":26},"配筋构造不正确，应沿梁侧面各配1Φ10构造纵筋",{"key":28,"text":87,"correct":22},"配筋构造不正确，应沿梁侧面各配1Φ14构造纵筋",{"key":31,"text":89,"correct":26},"配筋构造不正确，应沿梁侧面各配2Φ10构造纵筋",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":24,"analysis":33},928608,"某规则结构各层平面如图所示，荷载分布较均匀。现采用简化方法，按X、Y两个正交方向分别计算水平地震作用效应（不考虑扭转），并通过将该地震作用效应乘以放大系数来考虑地震扭转效应。试根据《建筑抗震设计规范》（GB 50011—2010）判断，下列框架的地震作用效应增大系数，其中何项较为合适？（ ）[2012年真题]",[94,96,98,100],{"key":20,"text":95,"correct":26},"KJ1：1.02",{"key":24,"text":97,"correct":22},"KJ3：1.05",{"key":28,"text":99,"correct":26},"K13：1.15",{"key":31,"text":101,"correct":26},"KJ2.KJ4：1.10",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":24,"analysis":33},928609,"某工地需使用盘条供应的钢筋，使用前采用冷拉方法调直。试问，钢筋采用HRB335级，调直时钢筋的冷拉率不宜大于下列何项数值？（ ）[2011年真题]",[106,108,110,112],{"key":20,"text":107,"correct":26},"0.5％",{"key":24,"text":109,"correct":22},"1％",{"key":28,"text":111,"correct":26},"1.5％",{"key":31,"text":113,"correct":26},"2％",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":28,"analysis":33},928610,"某钢筋混凝土柱的截面尺寸300mm×500mm，柱计算长度l0＝6m，轴向力设计值N＝1300kN，弯矩设计值M＝253kN·m。采用混凝土强度等级为C20，纵向受力钢筋采用HRB335级。 2.若已知ξ＝0.829，对称配筋，则As应为（ ）mm2。",[118,120,122,124],{"key":20,"text":119,"correct":26},"1972",{"key":24,"text":121,"correct":26},"2056",{"key":28,"text":123,"correct":22},"2306",{"key":31,"text":125,"correct":26},"2496",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":28,"analysis":33},928611,"某钢筋混凝土柱的截面尺寸300mm×500mm，柱计算长度l0＝6m，轴向力设计值N＝1300kN，弯矩设计值M＝253kN·m。采用混凝土强度等级为C20，纵向受力钢筋采用HRB335级。 1.若设计成对称配筋，相对受压区高度ξ应为（ ）。",[130,132,134,136],{"key":20,"text":131,"correct":26},"0.418",{"key":24,"text":133,"correct":26},"0.550",{"key":28,"text":135,"correct":22},"0.679",{"key":31,"text":137,"correct":26},"0.981",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":20,"analysis":33},928612,"某钢筋混凝土无梁楼盖中柱的板柱节点如图所示，混凝土强度等级C35（ft=1.57N／mm2），as=30mm，安全等级为二级，环境类别为Ⅰ类。试问，在不配置箍筋和弯起钢筋的情况下，该中柱柱帽周边楼板的受冲切承载力Fl（kN），与下列何项数值最为接近？（ ）[2014年真题]",[142,144,146,148],{"key":20,"text":143,"correct":22},"1264",{"key":24,"text":145,"correct":26},"1470",{"key":28,"text":147,"correct":26},"2332",{"key":31,"text":149,"correct":26},"2530",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":33},928613,"某钢筋混凝土偏心受压柱，正方形截面，混凝土强度等级C50，四角各配置（HRB400级），每边各配置（HRB335级），则此钢筋混凝土偏心受压柱的截面相对界限受压区高度ξb为（ ）。",[154,156,158,159],{"key":20,"text":155,"correct":22},"0.518",{"key":24,"text":157,"correct":26},"0.544",{"key":28,"text":133,"correct":26},{"key":31,"text":160,"correct":26},"0.614",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":28,"analysis":33},928614,"某钢筋混凝土梁，同时承受弯矩、剪力和扭矩的作用，不考虑抗震设计。梁截面为400mm×500mm，混凝土强度等级C30，梁内配置四肢箍筋，箍筋采用HPB300级钢筋。经计算，Astl\u002Fs=0.65mm，Asv\u002Fs=2.15mm，其中，Astl为受扭计算中沿截面周边配置的箍筋单肢截面面积，Asv为受剪承载力所需的箍筋截面面积，s为沿构件长度方向的箍筋间距。试问，至少选用下列何项箍筋配置才能满足计算要求？（ ）[2011年真题]",[165,167,169,171],{"key":20,"text":166,"correct":26},"Φ8@100",{"key":24,"text":168,"correct":26},"Φ10@100",{"key":28,"text":170,"correct":22},"Φ12@100",{"key":31,"text":172,"correct":26},"Φ14@100",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":31,"analysis":33},928615,"某钢筋混凝土框架柱，抗震等级为四级，截面为b×h=400mm×400mm，采用C25混凝土，经计算，轴压比=0.40，剪跨比大于2.0。现拟采用HRB400钢筋作为复合箍。试问，该柱上下端加密区箍筋的最小体积配箍百分率与下列何项数值最为接近？（ ）[2012年真题]",[177,179,181,183],{"key":20,"text":178,"correct":26},"0.23％",{"key":24,"text":180,"correct":26},"0.28％",{"key":28,"text":182,"correct":26},"0.32％",{"key":31,"text":184,"correct":22},"0.40％",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":24,"analysis":33},928616,"某钢筋混凝土框架结构，框架抗震等级为二级，中间层框架中柱配筋示意见图，已知箍筋直径为10mm，且加密区箍筋间距为100mm。试问，该框架柱非加密区箍筋间距最大值（mm）与下列何项数值最为接近？（ ）[2012年真题] 提示：不考虑柱截面尺寸、剪跨比对箍筋配置的影响。该柱不需要提高变形能力。",[189,191,193,195],{"key":20,"text":190,"correct":26},"150",{"key":24,"text":192,"correct":22},"180",{"key":28,"text":194,"correct":26},"200",{"key":31,"text":196,"correct":26},"250",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":24,"analysis":33},928617,"某钢筋混凝土简支梁，安全等级为二级。梁截面250mm×600mm，混凝土强度等级C30，纵向受力钢筋均采用HRB335级钢筋，箍筋采用HPB300级钢筋，梁顶及梁底均配置纵向受力钢筋， 提示：相对界限受压区高度ξb=0.55。[2011年真题] 2.已知：梁底面配置了4Φ25受力钢筋，梁顶面钢筋可按需要配置。试问，如充分考虑受压钢筋的作用，此梁跨中可以承受的最大正弯矩设计值M（kN·m），应与下列何项数值最为接近？（ ）",[201,203,204,206],{"key":20,"text":202,"correct":26},"280",{"key":24,"text":43,"correct":22},{"key":28,"text":205,"correct":26},"450",{"key":31,"text":207,"correct":26},"770",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},928618,"某钢筋混凝土简支梁，安全等级为二级。梁截面250mm×600mm，混凝土强度等级C30，纵向受力钢筋均采用HRB335级钢筋，箍筋采用HPB300级钢筋，梁顶及梁底均配置纵向受力钢筋， 提示：相对界限受压区高度ξb=0.55。[2011年真题] 1.已知：梁顶面配置了2Φ16受力钢筋，梁底钢筋可按需要配置。试问，如充分考虑受压钢筋的作用，此梁跨中可以承受的最大正弯矩设计值M（kN·m），应与下列何项数值最为接近？（ ）",[212,214,216,218],{"key":20,"text":213,"correct":26},"455",{"key":24,"text":215,"correct":26},"480",{"key":28,"text":217,"correct":22},"519",{"key":31,"text":219,"correct":26},"536",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":24,"analysis":33},928619,"某钢筋混凝土方形柱为偏心受拉构件，安全等级为二级，柱混凝土强度等级C30，截面尺寸为400mm×400mm。柱内纵向钢筋仅配置了4根直径相同的角筋，角筋采用HRB335级钢筋， 已知：轴向拉力设计值N=250kN，单向弯矩设计值M=31kN·m。试问，按承载能力极限状态计算（不考虑抗震），角筋的直径（mm）至少应采用下列何项数值？（ ）[2011年真题]",[224,226,228,230],{"key":20,"text":225,"correct":26},"25",{"key":24,"text":227,"correct":22},"22",{"key":28,"text":229,"correct":26},"20",{"key":31,"text":231,"correct":26},"18",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":28,"analysis":33},928620,"某钢筋混凝土T形悬臂梁，安全等级为一级，混凝土强度C30，纵向受拉钢筋采用HRB335级钢筋，不考虑抗震设计。荷载简图及截面尺寸如图2-21所示。梁上作用有均布恒荷载标准值gk（已计入梁自重）。局部均布活荷载标准值qk，集中恒荷载标准值Pk。[2011年真题] 2.假定，悬臂梁根部截面按荷载效应组合的最大弯矩设计值Ma=850kN·m，as=60mm。试问，在不考虑受压钢筋作用的情况下，按承载能力极限状态设计，纵向受拉钢筋的截面面积As（mm2）与下列何项数值最为接近？（ ）提示：相对界限受压区高度ξb=0.55。",[236,237,239,241],{"key":20,"text":63,"correct":26},{"key":24,"text":238,"correct":26},"3900",{"key":28,"text":240,"correct":22},"4300",{"key":31,"text":242,"correct":26},"4700",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":28,"analysis":33},928621,"某钢筋混凝土T形悬臂梁，安全等级为一级，混凝土强度C30，纵向受拉钢筋采用HRB335级钢筋，不考虑抗震设计。荷载简图及截面尺寸如图2-21所示。梁上作用有均布恒荷载标准值gk（已计入梁自重）。局部均布活荷载标准值qk，集中恒荷载标准值Pk。[2011年真题] 1.已知：gk=15kN\u002Fm，qk=6kN\u002Fm，Pk=20kN，活荷载的分项系数为1.4，活荷载的组合值系数为0.7。试问，构件承载能力设计时，悬臂梁根部截面按荷载效应组合的最大弯矩设计值Ma（kN·m）与下列何项数值最为接近？（ ）",[247,249,251,253],{"key":20,"text":248,"correct":26},"580",{"key":24,"text":250,"correct":26},"600",{"key":28,"text":252,"correct":22},"620",{"key":31,"text":254,"correct":26},"640",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":31,"analysis":33},928622,"某多层住宅，采用现浇钢筋混凝土剪力墙结构，结构平面立面均规则，抗震等级为三级，以地下室顶板作为上部结构的嵌固部位。底层某双肢墙有 A、B两个墙肢。已知A墙肢截面组合的剪力计算值Vw=180kN，同时B墙肢出现了大偏心受拉。试问，A墙肢截面组合的剪力设计值V（kN），应与下列何项数值最为接近？（ ）[2011年真题]",[259,261,263,264],{"key":20,"text":260,"correct":26},"215",{"key":24,"text":262,"correct":26},"235",{"key":28,"text":196,"correct":26},{"key":31,"text":265,"correct":22},"270",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":28,"analysis":33},928623,"某叠合梁，结构安全等级为二级，叠合前截面尺寸300mm×450mm，混凝土强度等级C35，叠合后截面为300mm×600mm，叠合层的混凝土强度等级C30，配有双肢箍8@200，fyv=360N／mm2，as=40mm，试问，此叠合梁叠合面的受剪承载力设计值V（kN），与下列何项数值最为接近？（ ）[2014年真题]",[270,271,273,275],{"key":20,"text":265,"correct":26},{"key":24,"text":272,"correct":26},"297",{"key":28,"text":274,"correct":22},"374",{"key":31,"text":276,"correct":26},"402",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":31,"analysis":33},928624,"某单筋矩形截面梁b×h＝250mm×450mm，采用C20级混凝土，配置（HRB335级）纵向受力钢筋；当发生正截面破坏时，属于下列情况中的（ ）。 提示：ρmax＝0.55fc\u002Ffy，as＝40mm。",[281,283,285,287],{"key":20,"text":282,"correct":26},"平衡配筋梁的界限破坏",{"key":24,"text":284,"correct":26},"适筋梁破坏",{"key":28,"text":286,"correct":26},"少筋梁破坏",{"key":31,"text":288,"correct":22},"超筋梁破坏",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":33},928625,"某承受均布荷载的简支梁跨度l0＝5m，截面尺寸b×h＝200mm×500mm，混凝土强度等级为C20，箍筋为HPB300级，纵筋为HRB335级钢筋，单排纵向受力钢筋，梁净跨为5m，as＝40mm。假设梁的支座截面承受剪力设计值V＝150kN，则该截面所需的箍筋总面积与间距的比值Asv\u002Fs最接近于（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":26},"0.51",{"key":24,"text":296,"correct":26},"0.54",{"key":28,"text":298,"correct":22},"0.65",{"key":31,"text":300,"correct":26},"0.82",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":28,"analysis":33},928626,"某车间内设有一台电动葫芦如图，其轨道梁吊挂于钢梁AB下。钢梁两端连接于厂房框架柱上，计算跨度L=7000mm，计算简图如图所示。钢材采用Q235—B钢，钢梁选用热轧H型钢HN400×200×8×13，其截面特性：A=83.37×102mm2，Ιz=23500×10?mm?,Wx=1170×103mm3,iy=45.6mm。[2012年真题] 已知条件同题（1）。试问，钢梁C点处由可变荷载Qk产生的最大挠度值（mm）应与下列何项数值最为接近？（ ）",[305,307,309,311],{"key":20,"text":306,"correct":26},"4",{"key":24,"text":308,"correct":26},"6",{"key":28,"text":310,"correct":22},"10",{"key":31,"text":312,"correct":26},"14",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},928627,"某车间内设有一台电动葫芦如图，其轨道梁吊挂于钢梁AB下。钢梁两端连接于厂房框架柱上，计算跨度L=7000mm，计算简图如图所示。钢材采用Q235—B钢，钢梁选用热轧H型钢HN400×200×8×13，其截面特性：A=83.37×102mm2，Ιz=23500×10?mm?,Wx=1170×103mm3,iy=45.6mm。[2012年真题] 1.为便于对钢梁AB进行计算，将电动葫芦轨道梁、相关连接件和钢梁等自重折合为一集中荷载标准值Gk=6kN，作用于C点处钢梁下翼缘，电动葫芦自重和吊重合计的荷载标准值Qk=66kN（按动力荷载考虑），不考虑电动葫芦的水平荷载。已知C点处钢梁对x轴的净截面模量Wyx=1050×103mm3。试问，钢梁C点处的最大应力计算数值（N\u002Fmm2）应与下列何项数值最为接近？（ ）",[317,318,320,321],{"key":20,"text":194,"correct":26},{"key":24,"text":319,"correct":22},"165",{"key":28,"text":190,"correct":26},{"key":31,"text":322,"correct":26},"130",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":31,"analysis":33},928628,"某7度区某钢筋混凝土标准设防类多层建筑，设计地震分组为第二组，设计基本地震加速度为0.1g，场地类别为Ⅱ类。[2012年真题] 1.试问，罕遇地震下弹塑性位移验算时的水平地震影响系数最大值 应分别采用下列何项数值？（ ）",[327,329,331,333],{"key":20,"text":328,"correct":26},"0.08，0.35",{"key":24,"text":330,"correct":26},"0.12，0.40",{"key":28,"text":332,"correct":26},"0.50，0.40",{"key":31,"text":334,"correct":22},"0.50，0.45",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":20,"analysis":33},928629,"某7度区某钢筋混凝土标准设防类多层建筑，设计地震分组为第二组，设计基本地震加速度为0.1g，场地类别为Ⅱ类。[2012年真题] .假设，该建筑结构本身的计算自振周期为0.5s，周期折减系数为0.8。试问，多遇地震作用下的水平地震影响系数与下列何项数值最为接近？（ ）",[339,341,343,345],{"key":20,"text":340,"correct":22},"0.08",{"key":24,"text":342,"correct":26},"0.09",{"key":28,"text":344,"correct":26},"0.10",{"key":31,"text":346,"correct":26},"0.12",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":31,"analysis":33},928630,"某6度区标准设防类钢筋混凝土框架结构办公楼如图，房屋高度为22m，地震分组为第一组，场地类别为Ⅱ类。其中一根框架角柱，分别与跨度为8m和10m的框架梁相连，剪跨比为1.90，截面及配筋如图3所示，混凝土强度等级C40。试问，该框架柱的轴压比限值与下列何项数值最为接近？（ ）[2012年真题] 提示：可不复核柱的最小配箍特征值。",[351,353,355,357],{"key":20,"text":352,"correct":26},"0.80",{"key":24,"text":354,"correct":26},"0.85",{"key":28,"text":356,"correct":26},"0.90",{"key":31,"text":358,"correct":22},"0.95",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":28,"analysis":33},928631,"某2层钢筋混凝土办公楼浴室的简支楼面梁如图，安全等级为二级，从属面积为13.5，计算跨度为6.0m，梁上作用恒荷载标准值gk=14.0kN\u002Fm（含梁自重），按等效均布荷载计算的梁上活荷载标准值=4.5kN\u002Fm。[2012年真题] 假定，该梁两端均与框架柱刚接，当进行截面抗震验算时，试问，该梁在重力荷载代表值作用下按简支梁计算的梁端剪力设计值VGb（kN）与下列何项数值最为接近？（ ） 提示：假定重力荷载对该梁抗震不利。 {图}",[363,365,367,369],{"key":20,"text":364,"correct":26},"40",{"key":24,"text":366,"correct":26},"50",{"key":28,"text":368,"correct":22},"60",{"key":31,"text":370,"correct":26},"65",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":20,"analysis":33},928632,"某2层钢筋混凝土办公楼浴室的简支楼面梁如图，安全等级为二级，从属面积为13.5，计算跨度为6.0m，梁上作用恒荷载标准值gk=14.0kN\u002Fm（含梁自重），按等效均布荷载计算的梁上活荷载标准值=4.5kN\u002Fm。[2012年真题] 试问，梁跨中弯矩基本组合设计值M（kN·m）、标准组合设计值Mk（kN·m）、准永久组合设计值（kN·m）分别与下列何项数值最为接近？（ ）",[375,376,377,378],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":31,"analysis":33},928633,"梁的正截面破坏形式有适筋梁破坏、超筋梁破坏、少筋梁破坏，它们的破坏性质是（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":26},"都属于塑性破坏",{"key":24,"text":386,"correct":26},"都属于脆性破坏",{"key":28,"text":388,"correct":26},"适筋梁.超筋梁属脆性破坏，少筋梁属塑性破坏",{"key":31,"text":390,"correct":22},"适筋梁属延性破坏，超筋梁.少筋梁属脆性破坏",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":33},928634,"假设，某3层钢筋混凝土结构房屋，位于非抗震设防区，房屋高度9.0m，钢筋混凝土墙墙厚200mm，配置双层双向分布钢筋。试问，墙体双层水平分布钢筋的总配筋率最小值及双层竖向分布钢筋的总配筋率最小值分别与下列何项数值最为接近？（ ）[2012年真题]",[395,397,399,401],{"key":20,"text":396,"correct":22},"0.15％，0.15％",{"key":24,"text":398,"correct":26},"0.20％，0.15％",{"key":28,"text":400,"correct":26},"0.20％，0.20％",{"key":31,"text":402,"correct":26},"0.30％，0.30％",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":28,"analysis":33},928635,"假定，框架的抗震等级为二级，底层角柱截面尺寸及配筋形式如图所示，施工时要求箍筋采用HPB300（），柱箍筋混凝土保护层厚度为20mm，轴压比为0.6，剪跨比为3.0。如仅从抗震构造措施方面考虑，试验算该柱箍筋配置选用下列何项才能符合规范的最低构造要求？（ ） 提示：扣除重叠部分箍筋。",[407,408,410,411],{"key":20,"text":166,"correct":26},{"key":24,"text":409,"correct":26},"Φ8@100／200",{"key":28,"text":168,"correct":22},{"key":31,"text":412,"correct":26},"Φ10@100／200",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},928636,"假定，钢筋混凝土矩形截面简支梁如图下，梁跨度为5.4m，截面尺寸b×h=250mm×450mm，混凝土强度等级为C30，纵筋采用HRB400钢筋，箍筋采用HPB300钢筋，该梁的跨中受拉区纵筋As=620mm2，受扭纵筋Astl=280mm2（满足受扭纵筋最小配筋率要求），受剪箍筋Asvl／s=0.112mm2／mm，受扭箍筋Astl／s=0.2mm2／mm，试问，该梁跨中截面配筋应取下图何项？（ ）[2014年真题]",[417,418,419,420],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":26},{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":28,"analysis":33},928637,"关于预制构件吊环的以下3种说法： Ⅰ．应采用HPB300或更高强度的钢筋制作。当采用HRB335级钢筋时，末端可不设弯钩； Ⅱ．宜采用HPB300级钢筋制作。考虑到该规格材料用量可能很少，采购较难，也允许采用HRB335级钢筋制作，但其容许应力和锚固均应按HPB300级钢筋采用； Ⅲ．应采用HPB300级钢筋。在过渡期内允许使用HPB235级钢筋，但应控制截面的应力不超过50N\u002Fmm2。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[425,427,429,431],{"key":20,"text":426,"correct":26},"Ⅰ.Ⅱ.Ⅲ均错误",{"key":24,"text":428,"correct":26},"Ⅰ正确，Ⅱ.Ⅲ错误",{"key":28,"text":430,"correct":22},"Ⅱ正确，Ⅰ.Ⅲ错误",{"key":31,"text":432,"correct":26},"Ⅲ正确，Ⅰ.Ⅱ错误",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":28,"analysis":33},928638,"关于预应力混凝土构件的下列说法，何项不正确？（ ）[2014年真题]",[437,439,441,443],{"key":20,"text":438,"correct":26},"提高了构件的斜截面受剪承载力",{"key":24,"text":440,"correct":26},"有效改善了构件的正常使用极限状态性能",{"key":28,"text":442,"correct":22},"预应力混凝土的强度等级不宜低于C30",{"key":31,"text":444,"correct":26},"钢绞线的张拉控制应力取值应按其极限强度标准值计算",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":31,"analysis":33},928639,"关于预埋件及连接件设计的下列4种说法： Ⅰ.预埋件锚筋中心至锚板边缘的距离不应小于2d和20mm（d为锚筋直径）； Ⅱ.受拉直锚筋和弯折锚筋的锚固长度不应小于35d（d为锚筋直径）； Ⅲ.直锚筋与锚板应采用T形焊接，当锚筋直径不大于20mm时宜采用压力埋弧焊； Ⅳ.当一个预制构件上设有4个吊环时，应按3个吊环进行计算，在构件的自重标准值作用下，每个吊环的钢筋应力不应大于50N／mm2。试问，以下何项是全部正确的？（ ）[2013年真题]",[449,451,453,455],{"key":20,"text":450,"correct":26},"Ⅰ.Ⅲ.Ⅳ",{"key":24,"text":452,"correct":26},"Ⅰ.Ⅱ.Ⅲ",{"key":28,"text":454,"correct":26},"Ⅱ.Ⅲ",{"key":31,"text":456,"correct":22},"Ⅰ.Ⅲ",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":20,"analysis":33},928640,"关于框架结构竖向活荷载最不利布置的方法，下列论述不正确的是（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":22},"满布荷载法：活荷载同时作用于所有梁，求出支座和跨中弯矩直接用于内力组合",{"key":24,"text":464,"correct":26},"分层组合法：以分层法为依据，对梁只考虑本层活荷载最不利布置；对柱弯矩仅考虑上.下层活荷载影响；对柱轴力，必须考虑该层以上相邻梁布置活荷载",{"key":28,"text":466,"correct":26},"最不利荷载位置法：根据框架截面指定内力的影响线确定活荷载最不利布置",{"key":31,"text":468,"correct":26},"分跨计算组合法：活荷载逐层逐跨单独布置，分别计算内力，最后组合最不利内力",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":33},928641,"关于抗震设计时的构造要求，下列叙述正确的是（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":26},"抗震等级为一级的框架梁，采用C30混凝土，HRB335级钢筋，则其支座纵向受力钢筋的最小配筋率应为0.381%",{"key":24,"text":476,"correct":22},"建造在Ⅳ类场地上房屋高度为75m的框架—剪力墙结构，8度设防，丙类建筑；采用C50混凝土，HRB335级钢筋，则其框架角柱全部纵向受力钢筋的最小配筋率应为1.3%",{"key":28,"text":478,"correct":26},"铰接排架柱的箍筋加密区长度，对吊车梁区段，取上柱根部至吊车梁顶面",{"key":31,"text":480,"correct":26},"抗震等级为一级的铰接排架柱，其角柱柱顶箍筋加密区内箍筋最大间距为100mm，最小直径为8mm",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":28,"analysis":33},928642,"关于混凝土叠合构件，下列表述何项不正确？（ ）[2014年真题]",[485,487,489,491],{"key":20,"text":486,"correct":26},"考虑预应力长期影响，可将计算所得的预应力混凝土叠合构件在使用阶段的预应力反拱值乘以增大系数1.75",{"key":24,"text":488,"correct":26},"叠合梁的斜截面受剪承载力计算应取叠合层和预制构件中的混凝土强度等级的较低值",{"key":28,"text":490,"correct":22},"叠合梁的正截面受弯承载力计算应取叠合层和预制构件中的混凝土强度等级的较低值",{"key":31,"text":492,"correct":26},"叠合板的叠合层混凝土厚度不应小于40mm，混凝土强度等级不宜低于C25",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":28,"analysis":33},928643,"关于钢筋混凝土构件的以下3种说法： Ⅰ．局部受压承载力计算公式两侧均为设计值； Ⅱ．裂缝宽度计算时，荷载组合的效应为准永久值，而不是设计值； Ⅲ．非预应力钢筋混凝土受弯构件最大挠度按荷载准永久组合，并考虑荷载长期作用的影响进行计算。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[497,499,501,503],{"key":20,"text":498,"correct":26},"Ⅰ.Ⅱ正确，Ⅲ错误",{"key":24,"text":500,"correct":26},"Ⅱ.Ⅲ正确，Ⅰ错误",{"key":28,"text":502,"correct":22},"Ⅰ.Ⅲ正确，Ⅱ错误",{"key":31,"text":504,"correct":26},"Ⅰ.Ⅱ.Ⅲ均正确",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":31,"analysis":33},928644,"关于非抗震预应力混凝土受弯构件受拉一侧受拉钢筋的最小配筋百分率的以下3种说法： Ⅰ．预应力钢筋的配筋百分率不得少于0.2和45∫z\u002F∫y的较大值； Ⅱ．非预应力钢筋的最小配筋百分率为0.2； Ⅲ．受拉钢筋最小配筋百分率不得少于按正截面受弯承载力设计值等于正截面开裂弯矩值的原则确定的配筋百分率。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[509,510,511,512],{"key":20,"text":426,"correct":26},{"key":24,"text":428,"correct":26},{"key":28,"text":430,"correct":26},{"key":31,"text":432,"correct":22},{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":31,"analysis":33},928645,"根据《混凝土结构设计规范》（GB 50010—2010），下列表述正确的是（ ）。",[517,519,521,523],{"key":20,"text":518,"correct":26},"配置抗冲切箍筋的钢筋混凝土楼板，其冲切破坏前有明显预兆，呈延性破坏",{"key":24,"text":520,"correct":26},"受弯构件进行疲劳验算时，受压区混凝土应力图形可简化为等效的矩形应力图",{"key":28,"text":522,"correct":26},"对于进行疲劳强度验算的受弯构件，其主拉应力由箍筋或弯起钢筋承受，不考虑混凝土的作用",{"key":31,"text":524,"correct":22},"在吊车梁疲劳强度验算中，荷载应取用标准值，当吊车为重级工作制时，对吊车的竖向荷载应考虑动力系数1.1",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":24,"analysis":33},928646,"钢筋混凝土梁底有锚板和对称配置的直锚筋所组成的受力预埋件，如图所示。构件安全等级均为二级，混凝土强度等级为C35，直锚筋为6φ16（HRB400级），已采取防止锚板弯曲变形的措施。所承受的荷载F作用点位于锚板表面中心，力的作用方向如图所示。[2011年真题] 2.在Fmax作用下且直锚筋未采取附加横向钢筋等措施时，图中数值a（mm）至少应取下列何项数值？（ ）",[529,530,532,534],{"key":20,"text":366,"correct":26},{"key":24,"text":531,"correct":22},"70",{"key":28,"text":533,"correct":26},"100",{"key":31,"text":535,"correct":26},"120",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":24,"analysis":33},928647,"钢筋混凝土梁底有锚板和对称配置的直锚筋所组成的受力预埋件，如图所示。构件安全等级均为二级，混凝土强度等级为C35，直锚筋为6φ16（HRB400级），已采取防止锚板弯曲变形的措施。所承受的荷载F作用点位于锚板表面中心，力的作用方向如图所示。[2011年真题] 1.当不考虑地震作用组合时，该预埋件可以承受的最大荷载设计值Fmax（kN）与下列何项数值最为接近？（ ）提示：预埋件承载力由锚筋面积控制。",[540,541,542,543],{"key":20,"text":63,"correct":26},{"key":24,"text":238,"correct":22},{"key":28,"text":240,"correct":26},{"key":31,"text":242,"correct":26},{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":28,"analysis":33},928648,"非抗震设计的钢筋混凝土梁，采用C30混凝土，HRB335级钢筋。梁内配置纵向受拉钢筋4Φ22。 1.若纵向受拉钢筋采用绑扎搭接接头，接头方式如图所示，则纵向受力钢筋最小搭接长度ll（mm）与下列（ ）项数值最为接近。",[548,550,552,554],{"key":20,"text":549,"correct":26},"650",{"key":24,"text":551,"correct":26},"780",{"key":28,"text":553,"correct":22},"910",{"key":31,"text":555,"correct":26},"1050",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":28,"analysis":33},928649,"从混凝土受压构件的承载力N-M相关关系中得出的下述结论正确的是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":26},"当M一定时，对小偏压柱，应取N小的组合控制截面设计",{"key":24,"text":563,"correct":26},"当M一定时，对大偏压柱，应取N大的组合控制截面设计",{"key":28,"text":565,"correct":22},"当N一定时，无论大.小偏压柱都要取M尽可能大的组合控制截面设计",{"key":31,"text":567,"correct":26},"轴压时的受压承载力最大，Nmax＝N0；纯弯时的受弯承载力最大，Mmax＝M0",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":20,"analysis":33},928650,"板柱结构，柱网尺寸8.1m×8.1m，板厚200mm，中柱截面尺寸为b×h=700mm×700mm，采用C30混凝土，受冲切钢筋用HPB300级，若板上作用的荷载设计值g＋q=11.8kN\u002Fmm2，则仅采用箍筋作为受冲切钢筋所需的箍筋面积Asuv最接近于（ ）mm2。 提示：as=20mm，γ0=1.0。",[572,574,576,578],{"key":20,"text":573,"correct":22},"1432.1",{"key":24,"text":575,"correct":26},"1520.3",{"key":28,"text":577,"correct":26},"1641.8",{"key":31,"text":579,"correct":26},"1720.7",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":20,"analysis":33},928651,"在钢筋混凝土双筋梁中，大偏心受压和大偏心受拉构件的正截面承载力计算中，要求受压区高度x≥2a′，是为了（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":22},"保证受压钢筋在构件破坏时能达到其抗压强度设计值",{"key":24,"text":587,"correct":26},"防止受压钢筋压屈",{"key":28,"text":589,"correct":26},"避免保护层剥落",{"key":31,"text":591,"correct":26},"保证受压钢筋在构件破坏时能达到极限抗压强度",[593,596,599,602,605,608],{"id":15,"name":594,"category":7,"favorite":595},"领导干部任职前廉政法规知识测试题",92,{"id":597,"name":598,"category":7,"favorite":15},595,"建筑结构与设备",{"id":600,"name":601,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":603,"name":604,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":606,"name":607,"category":7,"favorite":8},534,"BIM工程师",{"id":609,"name":607,"category":7,"favorite":8},535]