[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":605},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,14,50,1330,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,189,201,213,225,237,249,261,270,282,294,306,318,330,342,353,365,374,384,396,406,417,428,440,451,462,473,485,497,509,521,533,545,557,569,581,593],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},929202,1,"单选题","按下列条件确定。图为某办公楼底层局部承重横墙的示意图。墙体厚240mm，横墙间距6m，采用Mu10普通砖、M5混合砂浆砌筑。 试验算外纵墙上截面为b×h=240mm×400mm的钢筋混凝土挑梁下砖砌体的局部受压承载力（kN），并指出其值与下列何项数值最为接近？（ ）",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","132.7",false,{"key":24,"text":25,"correct":22},"B","159.3",{"key":27,"text":28,"correct":22},"C","166.9",{"key":30,"text":31,"correct":32},"D","191.1",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},929203,"某配筋砌块砌体剪力墙房屋，高25m，处于8度地震区，首层剪力墙截面尺寸如图4-27所示，墙体高度4400mm。已知砌块强度MU20、砂浆Mb15、灌孔混凝土Cb30。 已知剪力墙的剪力设计值为V=245kN，则底部加强部位截面组合剪力设计值VW应为（ ）kN。",[38,40,42,44],{"key":20,"text":39,"correct":32},"392",{"key":24,"text":41,"correct":22},"343",{"key":27,"text":43,"correct":22},"294",{"key":30,"text":45,"correct":22},"245",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},929204,"某配筋砌块砌体剪力墙房屋，高25m，处于8度地震区，首层剪力墙截面尺寸如图4-27所示，墙体高度4400mm。已知砌块强度MU20、砂浆Mb15、灌孔混凝土Cb30。 砌块的孔洞率为46%，灌孔率为1.0，灌孔砌块砌体的抗压强度设计值应为（ ）N\u002Fmm2。",[50,52,54,56],{"key":20,"text":51,"correct":22},"7.43",{"key":24,"text":53,"correct":32},"6.98",{"key":27,"text":55,"correct":22},"5.68",{"key":30,"text":57,"correct":22},"4.32",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},929205,"某配筋砌块砌体剪力墙房屋，高25m，处于8度地震区，首层剪力墙截面尺寸如图4-27所示，墙体高度4400mm。已知砌块强度MU20、砂浆Mb15、灌孔混凝土Cb30。 剪力墙弯矩设计值M=1177.69kN·m，轴力设计值N=1288.41kN，采用对称配筋，判断大小偏心受压时，最接近于（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":32},"1219mm；2703mm",{"key":24,"text":65,"correct":22},"1219mm；3060mm",{"key":27,"text":67,"correct":22},"1272mm；2703mm",{"key":30,"text":69,"correct":22},"1272mm；3060mm",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},929206,"某配筋砌块砌体剪力墙房屋，高25m，处于8度地震区，首层剪力墙截面尺寸如图4-27所示，墙体高度4400mm。已知砌块强度MU20、砂浆Mb15、灌孔混凝土Cb30。 进行剪力墙斜截面承载力验算、截面尺寸校核时，最接近于（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"245kN；1263.8kN",{"key":24,"text":77,"correct":22},"245kN；1790.4kN",{"key":27,"text":79,"correct":32},"392kN；1263.8kN",{"key":30,"text":81,"correct":22},"392kN；1790.4kN",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},929207,"某配筋砌块砌体剪力墙房屋，高25m，处于8度地震区，首层剪力墙截面尺寸如图4-27所示，墙体高度4400mm。已知砌块强度MU20、砂浆Mb15、灌孔混凝土Cb30。 剪力墙的水平分布钢筋，应选择（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"按计算配筋",{"key":24,"text":89,"correct":22},"按构造；0.10%",{"key":27,"text":91,"correct":22},"按构造；0.11%",{"key":30,"text":93,"correct":32},"按构造；0.13%",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},929208,"某六层混凝土砌块结构住宅，屋面及楼板均采用现浇混凝土，横墙、纵墙承重，标准层层高为2.8m，所有承重墙均为190mm厚砌块。全部墙体采用Mu10砌块、Mu10砂浆，芯柱Cb20混凝土，设防烈度7度。图4-28所示为单元的平、剖面图。 各层重力荷载代表值：六层为1227.37kN，二～五层为1636.41kN，首层为1383.72kN，底部总水平地震作用标准值（kN）为下列哪一项？（ ）",[98,100,102,104],{"key":20,"text":99,"correct":32},"622.66",{"key":24,"text":101,"correct":22},"732.54",{"key":27,"text":103,"correct":22},"1245.32",{"key":30,"text":105,"correct":22},"1465.08",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},929209,"某六层混凝土砌块结构住宅，屋面及楼板均采用现浇混凝土，横墙、纵墙承重，标准层层高为2.8m，所有承重墙均为190mm厚砌块。全部墙体采用Mu10砌块、Mu10砂浆，芯柱Cb20混凝土，设防烈度7度。图4-28所示为单元的平、剖面图。 下列四项中，哪一项是五层地震剪力设计值V5（kN）？（ ）",[110,112,114,116],{"key":20,"text":111,"correct":32},"296.33",{"key":24,"text":113,"correct":22},"300.32",{"key":27,"text":115,"correct":22},"385.23",{"key":30,"text":117,"correct":22},"390.42",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},929210,"某六层混凝土砌块结构住宅，屋面及楼板均采用现浇混凝土，横墙、纵墙承重，标准层层高为2.8m，所有承重墙均为190mm厚砌块。全部墙体采用Mu10砌块、Mu10砂浆，芯柱Cb20混凝土，设防烈度7度。图4-28所示为单元的平、剖面图。 进行墙体截面抗震承载力验算时，下列四个墙肢中，哪一个是最不利的墙肢？（ ）",[122,124,126,128],{"key":20,"text":123,"correct":22},"横墙、12轴墙肢",{"key":24,"text":125,"correct":22},"横墙13轴、B轴～C轴墙肢",{"key":27,"text":127,"correct":32},"纵墙B轴、13轴～16轴墙肢",{"key":30,"text":129,"correct":22},"纵墙C轴、15轴处墙间墙",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":30,"analysis":33},929211,"某六层混凝土砌块结构住宅，屋面及楼板均采用现浇混凝土，横墙、纵墙承重，标准层层高为2.8m，所有承重墙均为190mm厚砌块。全部墙体采用Mu10砌块、Mu10砂浆，芯柱Cb20混凝土，设防烈度7度。图4-28所示为单元的平、剖面图。 纵向B轴，13轴～16轴墙肢，首层Vi=175.22kN，σ0=0.34MPa，V计\u002FVi的比值应为下列哪一项？（ ）",[134,136,138,140],{"key":20,"text":135,"correct":22},"2.31",{"key":24,"text":137,"correct":22},"2.14",{"key":27,"text":139,"correct":22},"2.04",{"key":30,"text":141,"correct":32},"1.88",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},929212,"下述关于影响砌体结构受压构件高厚比卢计算值的说法，哪一项是不对的？（ ）",[146,148,150,152],{"key":20,"text":147,"correct":22},"改变墙体厚度",{"key":24,"text":149,"correct":32},"改变砌筑砂浆的强度等级",{"key":27,"text":151,"correct":22},"改变房屋的静力计算方案",{"key":30,"text":153,"correct":22},"调整或改变构件支承条件",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":27,"analysis":33},929213,"某砖砌体和钢筋混凝土构造柱组合墙，如图所示，结构安全等级二级。构造柱截面均为240mm×240mm，混凝土采用C20（fc=9.6MPa）。砌体采用MU10烧结多孔砖和M7.5混合砂浆砌筑，构造措施满足规范要求，施工质量控制等级为B级；承载力验算时不考虑墙体自重。 .假定，房屋的静力计算方案为刚性方案，其所在二层层高为3.0m。构造柱纵向钢筋配4φ14（fy=270MPa），试问，该组合墙体单位墙长的轴心受压承载力设计值（kN／m）与下列何项数值最为接近？（ ） 提示：强度系数η=0.646。",[158,160,162,164],{"key":20,"text":159,"correct":22},"300",{"key":24,"text":161,"correct":22},"400",{"key":27,"text":163,"correct":32},"500",{"key":30,"text":165,"correct":22},"600",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},929214,"某砖砌体和钢筋混凝土构造柱组合墙，如图所示，结构安全等级二级。构造柱截面均为240mm×240mm，混凝土采用C20（fc=9.6MPa）。砌体采用MU10烧结多孔砖和M7.5混合砂浆砌筑，构造措施满足规范要求，施工质量控制等级为B级；承载力验算时不考虑墙体自重。 假定，组合墙中部构造柱顶作用一偏心荷载，其轴向压力设计值N=672kN，在墙体平面外方向的砌体截面受压区高度x=120mm。构造柱纵向受力钢筋为HPB300级，采用对称配筋，as=a's=35mm。试问，该构造柱计算所需总配筋值（mm2）与下列何项数值最为接近？（ ） 提示：计算截面宽度取构造柱的间距。",[170,172,174,176],{"key":20,"text":171,"correct":22},"310",{"key":24,"text":173,"correct":32},"440",{"key":27,"text":175,"correct":22},"610",{"key":30,"text":177,"correct":22},"800",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":180,"answer":27,"analysis":33},929215,[181,183,185,187],{"key":20,"text":182,"correct":22},"7.30\u003C11.00",{"key":24,"text":184,"correct":22},"8.30\u003C11.00",{"key":27,"text":186,"correct":32},"7.30\u003C12.65",{"key":30,"text":188,"correct":22},"10.33\u003C12.65",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":30,"analysis":33},929216,"关于木结构房屋设计，下列说法中何种选择是错误的？（ ）",[193,195,197,199],{"key":20,"text":194,"correct":22},"对于木柱木屋架房屋，可采用贴砌在木柱外侧的烧结普通砖砌体，并应与木柱采取可靠拉结措施",{"key":24,"text":196,"correct":22},"对于有抗震要求的木柱木屋架房屋，其屋架与木柱连接处均须设置斜撑",{"key":27,"text":198,"correct":22},"对于木柱木屋架房屋，当有吊车使用功能时，屋盖除应设置上弦横向支撑外，尚应设置垂直支撑",{"key":30,"text":200,"correct":32},"对于设防烈度为8度地震区建造的木柱木屋架房屋，除支撑结构与屋架采用螺栓连接外，椽与檩条、檩条与屋架连接均可采用钉连接",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":27,"analysis":33},929217,"某底层框架-抗震墙房屋，总层数四层。建筑抗震设防类别为丙类。砌体施工质量控制等级为8级。其中一榀框架立面如图4-4所示，托墙梁截面尺寸为300mm×600mm，框架柱截面尺寸均为500mm×500mm，柱、墙均居轴线中。 假定，抗震设防烈度为6度，试问，下列说法何项错误？（ ）",[205,207,209,211],{"key":20,"text":206,"correct":22},"抗震墙采用嵌砌于框架之间的约束砖砌体墙，先砌墙后浇筑框架。墙厚240mm，砌筑砂浆等级为M10，选用MU10级烧结普通砖",{"key":24,"text":208,"correct":22},"抗震墙采用嵌砌于框架之间的约束小砌块砌体墙，先砌墙后浇筑框架。墙厚190mm，砌筑砂浆等级为Mb10，选用MU10级单排孔混凝土小型空心砌块",{"key":27,"text":210,"correct":32},"抗震墙采用嵌砌于框架之间的约束砖砌体墙，先砌墙后浇筑框架。墙厚240mm，砌筑砂浆等级为M10，选用MU15级混凝土多孔砖",{"key":30,"text":212,"correct":22},"抗震墙采用嵌砌于框架之间的约束小砌块砌体墙。当满足抗震构造措施后，尚应对其进行抗震受剪承载力验算",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":27,"analysis":33},929218,"某底层框架-抗震墙房屋，总层数四层。建筑抗震设防类别为丙类。砌体施工质量控制等级为8级。其中一榀框架立面如图4-4所示，托墙梁截面尺寸为300mm×600mm，框架柱截面尺寸均为500mm×500mm，柱、墙均居轴线中。 假定，抗震设防烈度为7度，抗震墙采用嵌砌于框架之间的配筋小砌块砌体墙，墙厚190mm。抗震构造措施满足规范要求。框架柱上下端正截面受弯承载力设计值均为165 kN·m，砌体沿阶梯形截面破坏的抗震抗剪强度设计值fvE=0.52MPa。试问，其抗震受剪承载力设计值V（kN）与下列何项数值最为接近？（ ）",[217,219,221,223],{"key":20,"text":218,"correct":22},"1220",{"key":24,"text":220,"correct":22},"1250",{"key":27,"text":222,"correct":32},"1550",{"key":30,"text":224,"correct":22},"1640",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":27,"analysis":33},929219,"一下撑式木屋架，形状及尺寸如图所示，两端铰支于下部结构。其空间稳定措施满足规范要求。P为自檀条（与屋架上弦锚固）传至屋架的节点荷载。要求屋架露天环境下设计使用年限5年。选用西北云杉TC11A制作。 假定，杆件D1采用截面为正方形的方木，P=16.7kN（设计值）。试问，当按强度验算时，其设计最小截面尺寸（mm×mm）与下列何项数值最为接近？（ ） 提示：强度验算时不考虑构件自重。",[229,231,233,235],{"key":20,"text":230,"correct":22},"80×80",{"key":24,"text":232,"correct":22},"85×85",{"key":27,"text":234,"correct":32},"90×90",{"key":30,"text":236,"correct":22},"95×95",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":27,"analysis":33},929220,"一下撑式木屋架，形状及尺寸如图所示，两端铰支于下部结构。其空间稳定措施满足规范要求。P为自檀条（与屋架上弦锚固）传至屋架的节点荷载。要求屋架露天环境下设计使用年限5年。选用西北云杉TC11A制作。 假定，杆件D2采用截面为正方形的方木。试问，满足长细比要求的最小截面边长（mm）与下列何项数值最为接近？（ ）",[241,243,245,247],{"key":20,"text":242,"correct":22},"60",{"key":24,"text":244,"correct":22},"70",{"key":27,"text":246,"correct":32},"90",{"key":30,"text":248,"correct":22},"100",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":24,"analysis":33},929221,"关于砌体结构的以下论述： Ⅰ.砌体的抗压强度设计值以龄期为28d的毛截面面积计算；. Ⅱ.砂浆强度等级是用边长为70.7mm的立方体试块以MPa表示的抗压强度平均值确定； Ⅲ.砌体结构的材料性能分项系数，当施工质量控制等级为C级时，取为1.6； Ⅳ.砌体施工质量控制等级分为 A、 B、C三级，当施工质量控制等级为A级时，砌体强度设计值可提高10％。 试问，针对上述论述正确性的判断，下列何项正确？（ ）",[253,255,257,259],{"key":20,"text":254,"correct":22},"Ⅰ、Ⅳ正确，Ⅱ、Ⅲ错误",{"key":24,"text":256,"correct":32},"Ⅰ、Ⅱ正确，Ⅲ、Ⅳ错误",{"key":27,"text":258,"correct":22},"Ⅱ、Ⅲ正确，Ⅰ、Ⅳ错误",{"key":30,"text":260,"correct":22},"Ⅱ、Ⅳ正确，Ⅰ、Ⅲ错误",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":27,"analysis":33},929222,"关于砌体结构设计与施工的以下论述： Ⅰ.采用配筋砌体时，当砌体截面面积小于0.3m2时，砌体强度设计值的调整系数为构件截面面积（m2）加0.7； Ⅱ.对施工阶段尚未硬化的新砌砌体进行稳定验算时，可按砂浆强度为零进行验算； Ⅲ.在多遇地震作用下，配筋砌块砌体剪力墙结构楼层最大层间弹性位移角不宜超过1\u002F1000； Ⅳ.砌体的剪变模量可按砌体弹性模量的0.5倍采用。 试问，针对上述论述正确性的判断，下列何项正确？（ ）",[265,266,268,269],{"key":20,"text":256,"correct":22},{"key":24,"text":267,"correct":22},"Ⅰ、Ⅲ正确，Ⅱ、Ⅳ错误’",{"key":27,"text":258,"correct":32},{"key":30,"text":260,"correct":22},{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":20,"analysis":33},929223,"某多层砌体结构房屋，各层层高均为3.6m，内外墙厚度均为240mm，轴线居中。室内外高差0.3m，基础埋置较深且有刚性地坪。采用现浇钢筋混凝土楼、屋盖，平面布置图和A轴剖面见图4-12所示。各内墙上门洞均为1000mm×2600mm（宽×高），外墙上窗洞均为1800mm×1800mm（宽×高） 试问，底层②轴墙体的高厚比与下列何项数值最为接近？提示：横墙间距s按5.7m计算。（ ）",[274,276,278,280],{"key":20,"text":275,"correct":32},"13",{"key":24,"text":277,"correct":22},"15",{"key":27,"text":279,"correct":22},"17",{"key":30,"text":281,"correct":22},"19",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":27,"analysis":33},929224,"某多层砌体结构房屋，各层层高均为3.6m，内外墙厚度均为240mm，轴线居中。室内外高差0.3m，基础埋置较深且有刚性地坪。采用现浇钢筋混凝土楼、屋盖，平面布置图和A轴剖面见图4-12所示。各内墙上门洞均为1000mm×2600mm（宽×高），外墙上窗洞均为1800mm×1800mm（宽×高） 假定该房屋第二层横向（Y向）的水平地震剪力标准值V2k=2000kN。试问，第二层⑤轴墙体所承担的地震剪力标准值Vk（kN），应与下列何项数值最为接近？（ ）",[286,288,290,292],{"key":20,"text":287,"correct":22},"110",{"key":24,"text":289,"correct":22},"130",{"key":27,"text":291,"correct":32},"160",{"key":30,"text":293,"correct":22},"180",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":24,"analysis":33},929225,"某网状配筋砖砌体墙体，墙体厚度为240mm，墙体长度为6000mm，其计算高度H0=3600mm。采用MU10级烧结普通砖、M7.5级混合砂浆砌筑，砌体施工质量控制等级为B级。钢筋网采用冷拔低碳钢丝Φb4制作，其抗拉强度设计值fy=430MPa，钢筋网的网格尺寸a=60mm，竖向间距sn=240mm。 试问，轴心受压时，该配筋砖砌体抗压强度设计值fn（MPa），应与下列何项数值最为接近？（ ）",[298,300,302,304],{"key":20,"text":299,"correct":22},"2.6",{"key":24,"text":301,"correct":32},"2.8",{"key":27,"text":303,"correct":22},"3.0",{"key":30,"text":305,"correct":22},"3.2",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":27,"analysis":33},929226,"某网状配筋砖砌体墙体，墙体厚度为240mm，墙体长度为6000mm，其计算高度H0=3600mm。采用MU10级烧结普通砖、M7.5级混合砂浆砌筑，砌体施工质量控制等级为B级。钢筋网采用冷拔低碳钢丝Φb4制作，其抗拉强度设计值fy=430MPa，钢筋网的网格尺寸a=60mm，竖向间距sn=240mm。 假如砌体材料发生变化，已知fn=3.5MPa，网状配筋体积配筋率ρ=0.30％。试问，该配筋砖砌体的轴心受压承载力设计值（kN\u002Fm）应与下列何项数值最为接近？（ ）",[310,312,314,316],{"key":20,"text":311,"correct":22},"410",{"key":24,"text":313,"correct":22},"460",{"key":27,"text":315,"correct":32},"510",{"key":30,"text":317,"correct":22},"560",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},929227,"某五层砌体结构办公楼立面简图见图。抗震设防烈度7度，设计基本地震加速度值为0.15g。各层层高及计算高度均为3.6m，采用现浇钢筋混凝土楼、屋盖。砌体施工质量控制等级为B级，结构安全等级为二级。 已知各种荷载（标准值）：屋面恒载总重为1800kN，屋面活荷载总重150kN，屋面雪荷载总重100kN；每层楼层恒载总重为1600kN，按等效均布荷载计算的每层楼面活荷载为600kN；2～5层每层墙体总重为2100kN，女儿墙总重为400kN。采用底部剪力法对结构进行水平地震作用计算。试问，总水平地震作用标准值Fek（kN），应与下列何项数值最为接近？（ ） 提示：楼层重力荷载代表值计算时，集中于质点G1的墙体荷载按2100kN计算。",[322,324,326,328],{"key":20,"text":323,"correct":22},"1680",{"key":24,"text":325,"correct":32},"1970",{"key":27,"text":327,"correct":22},"2150",{"key":30,"text":329,"correct":22},"2300",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":30,"analysis":33},929228,"某五层砌体结构办公楼立面简图见图。抗震设防烈度7度，设计基本地震加速度值为0.15g。各层层高及计算高度均为3.6m，采用现浇钢筋混凝土楼、屋盖。砌体施工质量控制等级为B级，结构安全等级为二级。 采用底部剪力法对结构进行水平地震作用计算时，假设重力荷载代表值G1=G2=G3=G4=5000kN、G5=4000kN。若总水平地震作用标准值为Fek，截面抗震验算仅计算水平地震作用。试问，第二层的水平地震剪力设计值V2（kN）应与下列何项数值最为接近？（ ）",[334,336,338,340],{"key":20,"text":335,"correct":22},"0.8Fek",{"key":24,"text":337,"correct":22},"0.9Fek",{"key":27,"text":339,"correct":22},"1.1Fek",{"key":30,"text":341,"correct":32},"1.2Fek",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":27,"analysis":33},929229,"某悬臂砖砌水池，采用MU10级烧结普通砖、M10级水泥砂浆砌筑，墙体厚度740mm，砌体施工质量控制等级为B级。水压力按可变荷载考虑，假定其荷载分项系数取1.4。试问，按抗剪承载力验算时，该池壁底部能承受的最大水压高度设计值H（m），应与下列何项数值最为接近？（ ） 提示：①不计池壁自重的影响；②按《砌体结构设计规范》（GB 50003—2011）作答。",[346,348,349,351],{"key":20,"text":347,"correct":22},"2.5",{"key":24,"text":303,"correct":22},{"key":27,"text":350,"correct":32},"3.5",{"key":30,"text":352,"correct":22},"4.0",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":27,"analysis":33},929230,"一钢筋混凝土简支梁，截面尺寸为200mm×500mm，跨度5.4m，支承在240mm厚的窗间墙上，如图4-14所示。窗间墙长1500mm，采用MU15级蒸压粉煤灰砖、M10级混合砂浆砌筑，砌体施工质量控制等级为B级。在梁下、窗间墙墙顶部位，设置有钢筋混凝土圈梁，圈梁高度为180mm。梁端的支承压力设计值N1=110kN，上层传来的轴向压力设计值为360kN。试问，作用于垫梁下砌体局部受压的压力设计值N0+N1（kN），与下列何项数值最为接近？（ ）",[357,359,361,363],{"key":20,"text":358,"correct":22},"190",{"key":24,"text":360,"correct":22},"220",{"key":27,"text":362,"correct":32},"240",{"key":30,"text":364,"correct":22},"260",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":24,"analysis":33},929231,"关于木结构的以下论述： Ⅰ.用原木、方木制作承重构件时，木材的含水率不应大于30％ Ⅱ.木结构受拉或受弯构件应选用IA级材质的木材； Ⅲ.验算原木构件挠度和稳定时，可取中央截面； Ⅳ.对设计使用年限为25年的木结构构件，结构重要性系数γ0不应小于0.9。试问，针对上述论述正确性的判断，下列何项正确？（ ）",[369,370,371,372],{"key":20,"text":256,"correct":22},{"key":24,"text":258,"correct":32},{"key":27,"text":254,"correct":22},{"key":30,"text":373,"correct":22},"Ⅲ、Ⅳ正确，Ⅰ、Ⅱ错误",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":30,"analysis":33},929232,"用新疆落叶松原木制作的轴心受压柱，两端铰接，柱计算长度为3.2m，在木柱1.6m高度处有一个d=22mm的螺栓孔穿过截面中央，原木标注直径d=150mm。该受压杆件处于室内正常环境，安全等级为二级，设计使用年限为25年。试问，当按稳定验算时，柱的轴心受压承载力（kN），应与下列何项数值最为接近？（ ）[2012年真题] 提示：验算部位按经过切削考虑。",[378,380,381,383],{"key":20,"text":379,"correct":22},"95",{"key":24,"text":248,"correct":22},{"key":27,"text":382,"correct":22},"105",{"key":30,"text":287,"correct":32},{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":27,"analysis":33},929233,"关于砌体结构的设计，有下列四项论点： Ⅰ.某六层刚性方案砌体结构房屋，层高均为3.3m，均采用现浇钢筋混凝土楼板，外墙洞口水平截面面积约为全截面面积的60％，基本风压为0.6kN\u002Fm2，外墙静力计算时可不考虑风荷载的影响； Ⅱ.通过改变砌块强度等级可以提高墙、柱的允许高厚比； Ⅲ.在蒸压粉煤灰砖强度等级不大于MU20、砂浆强度等级不大于M10的条件下，为增加砌体抗压承载力，提高砖的强度等级一级比提高砂浆强度等级一级效果好； Ⅳ.厚度180mm、上端非自由端、无门窗洞口的自承重墙体，允许高厚比修正系数为1.32。 试问，以下何项组合是全部正确的？（ ）",[388,390,392,394],{"key":20,"text":389,"correct":22},"Ⅰ、Ⅲ",{"key":24,"text":391,"correct":22},"Ⅱ、Ⅲ",{"key":27,"text":393,"correct":32},"Ⅲ、Ⅳ",{"key":30,"text":395,"correct":22},"Ⅱ、Ⅳ",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":27,"analysis":33},929234,"某多层砌体结构房屋，顶层钢筋混凝土挑梁置于丁字形（带翼墙）截面的墙体上，端部设有构造柱，如图4-16所示；挑梁截面b×hb=240mm×450mm，墙体厚度均为240mm。屋面板传给挑梁的恒荷载及挑梁自重标准值为gk=27kN\u002Fm，不上人屋面，活荷载标准值为qk=3.5kN\u002Fm。试问，该挑梁的最大弯矩设计值（kN·m），与下列何项数值最为接近？（ ）",[400,401,403,404],{"key":20,"text":242,"correct":22},{"key":24,"text":402,"correct":22},"65",{"key":27,"text":244,"correct":32},{"key":30,"text":405,"correct":22},"75",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":30,"analysis":33},929235,"抗震等级为二级的配筋砌块砌体剪力墙房屋，首层某矩形截面剪力墙墙体厚度为190mm，墙体长度为5100mm，剪力墙截面的有效高度h0=4800mm，为单排孔混凝土砌块对孔砌筑，砌体施工质量控制等级为B级。若此段砌体剪力墙计算截面的剪力设计值V=210kN，轴力设计值N=1250kN，弯矩设计值M=1050kN·m，灌孔砌体的抗压强度设计值fx=7.5N\u002Fmm2。试问，底部加强部位剪力墙的水平分布钢筋配置，下列哪种说法合理？（ ） 提示：按《砌体结构设计规范》（GB 50003—2011）作答。",[410,411,413,415],{"key":20,"text":87,"correct":22},{"key":24,"text":412,"correct":22},"按构造，最小配筋率取0.10％",{"key":27,"text":414,"correct":22},"按构造，最小配筋率取0.11％",{"key":30,"text":416,"correct":32},"按构造，最小配筋率取0.13％",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":24,"analysis":33},929236,"露天环境下某工地采用红松原木制作混凝土梁底模立柱，强度验算部位未经切削加工，试问，在确定设计指标时，该红松原木轴心抗压强度最大设计值（N\u002Fmm2），与下列何项数值最为接近？（ ）",[421,423,425,427],{"key":20,"text":422,"correct":22},"10",{"key":24,"text":424,"correct":32},"12",{"key":27,"text":426,"correct":22},"14",{"key":30,"text":277,"correct":22},{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":27,"analysis":33},929237,"关于木结构，下列哪一种说法是不正确的？（ ）",[432,434,436,438],{"key":20,"text":433,"correct":22},"现场制作的原木、方木承重构件，木材的含水率不应大于25％",{"key":24,"text":435,"correct":22},"普通木结构受弯或压弯构件当采用原木时，对髓心不做限制指标",{"key":27,"text":437,"correct":32},"木材顺纹抗压强度最高，斜纹承压强度最低，横纹承压强度介于两者之间",{"key":30,"text":439,"correct":22},"标注原木直径时，应以小头为准；验算原木构件挠度和稳定时，可取中央截面",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":27,"analysis":33},929238,"设单排孔混凝土砌块为MU15级，采用Mb7.5级专用砂浆对孔砌筑，砌块孔洞率为30%；采用Cb25级灌孔混凝土，灌孔率为66.7%。则灌孔砌体的抗压强度设计值fg（MPa）与下列何项数值接近？（ ）",[444,446,447,449],{"key":20,"text":445,"correct":22},"3.61",{"key":24,"text":57,"correct":22},{"key":27,"text":448,"correct":32},"5.04",{"key":30,"text":450,"correct":22},"7.22",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":453,"answer":20,"analysis":33},929239,[454,456,458,460],{"key":20,"text":455,"correct":32},"188.7",{"key":24,"text":457,"correct":22},"209.7",{"key":27,"text":459,"correct":22},"214.2",{"key":30,"text":461,"correct":22},"227.9",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":464,"answer":20,"analysis":33},929240,[465,467,469,471],{"key":20,"text":466,"correct":32},"164.7",{"key":24,"text":468,"correct":22},"169.6",{"key":27,"text":470,"correct":22},"193.3",{"key":30,"text":472,"correct":22},"205.9",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":30,"analysis":33},929241,"某多层砌体刚性方案房屋底层局部承重横墙如图4-19所示。采用MU15级蒸压灰砂砖，M5级混合砂浆（±0.00以上）或M7.5级水泥砂浆（±0.00以下）砌筑（B级施工质量控制等级）。试计算单位长度横墙轴心受压承载力（kN\u002Fm）与下列何项数值接近？ （ ）",[477,479,481,483],{"key":20,"text":478,"correct":22},"216",{"key":24,"text":480,"correct":22},"236.7",{"key":27,"text":482,"correct":22},"246.6",{"key":30,"text":484,"correct":32},"300.8",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":27,"analysis":33},929242,"某截面为490mm×620mm的砖柱受轴向压力作用，采用强度等级为MU20烧结多孔砖及强度等级为M7.5的水泥混合砂浆砌筑，施工质量控制等级为C级，柱计算高度H0=H=6.0m，则该柱底截面轴向承载力（kN）与（ ）项数值最为接近。",[489,491,493,495],{"key":20,"text":490,"correct":22},"512.25",{"key":24,"text":492,"correct":22},"519.37",{"key":27,"text":494,"correct":32},"591.00",{"key":30,"text":496,"correct":22},"574.35",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":20,"analysis":33},929243,"截面尺寸为190mm×800mm的混凝土空心砌块墙段，砌块的强度等级为MU10，砌筑砂浆强度等级Mb5，墙高2.8m，两端为不动铰支座。沿墙段长边方向偏心距e=200mm。该墙段的受压承载力（kN）与下列何项数值最为接近？（ ）",[501,503,505,507],{"key":20,"text":502,"correct":32},"143.6",{"key":24,"text":504,"correct":22},"154.2",{"key":27,"text":506,"correct":22},"204.0",{"key":30,"text":508,"correct":22},"227.3",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},929244,"某5m高轴心受压砖柱，e=0，上下端均为不动铰支座，采用MU10和M5的混合砂浆砌筑，截面尺寸为490mm×490mm。 该柱受压承载力设计值（kN）与（ ）项数值相近。",[513,515,517,519],{"key":20,"text":514,"correct":32},"292.7",{"key":24,"text":516,"correct":22},"255.6",{"key":27,"text":518,"correct":22},"241.4",{"key":30,"text":520,"correct":22},"213.5",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":27,"analysis":33},929245,"某5m高轴心受压砖柱，e=0，上下端均为不动铰支座，采用MU10和M5的混合砂浆砌筑，截面尺寸为490mm×490mm。 当该柱采用网状配筋配置，钢筋为Φb4冷拔低碳钢丝，fy=430N\u002Fmm2，钢筋网竖向间距s=260mm（四皮砖），网格尺寸为60mm×60mm，已求得体积配筋率ρ=0.162，fn=2.522N\u002Fmm2，该网状配筋柱承载力（kN）与（ ）项数值最为接近。",[525,527,529,531],{"key":20,"text":526,"correct":22},"592.7",{"key":24,"text":528,"correct":22},"513.5",{"key":27,"text":530,"correct":32},"491.1",{"key":30,"text":532,"correct":22},"441.4",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":30,"analysis":33},929246,"组合砖柱的截面尺寸为370mm×620mm，计算高度为6.6m。采用MU10砖，M10混合砂浆砌筑，面层厚度和钢筋配置见图4-23。承受轴心压力。 该组合砖柱的稳定系数最接近（ ）项数值。",[537,539,541,543],{"key":20,"text":538,"correct":22},"0.85",{"key":24,"text":540,"correct":22},"0.81",{"key":27,"text":542,"correct":22},"0.76",{"key":30,"text":544,"correct":32},"0.70",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":27,"analysis":33},929247,"组合砖柱的截面尺寸为370mm×620mm，计算高度为6.6m。采用MU10砖，M10混合砂浆砌筑，面层厚度和钢筋配置见图4-23。承受轴心压力。 假设稳定系数φcom=0.75，则该组合柱的承载力（kN）与（ ）项数值最为接近。",[549,551,553,555],{"key":20,"text":550,"correct":22},"331",{"key":24,"text":552,"correct":22},"356",{"key":27,"text":554,"correct":32},"456",{"key":30,"text":556,"correct":22},"528",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":20,"analysis":33},929248,"某带壁柱的砖墙，采用砖Mu10、混合砂浆M5砌筑，柱的计算高度为3.6m，截面尺寸如图4-24所示。 轴向力作用于O点时的受压墙体的承载力（kN），接近下列（ ）项数值。",[561,563,565,567],{"key":20,"text":562,"correct":32},"520.65",{"key":24,"text":564,"correct":22},"473.72",{"key":27,"text":566,"correct":22},"354.99",{"key":30,"text":568,"correct":22},"236.66",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":20,"analysis":33},929249,"某带壁柱的砖墙，采用砖Mu10、混合砂浆M5砌筑，柱的计算高度为3.6m，截面尺寸如图4-24所示。 轴向力作用于A点时的受压墙体承载力（kN）接近下列（ ）项数值。",[573,575,577,579],{"key":20,"text":574,"correct":32},"304.36",{"key":24,"text":576,"correct":22},"281.24",{"key":27,"text":578,"correct":22},"239.05",{"key":30,"text":580,"correct":22},"210.93",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":24,"analysis":33},929250,"墙梁的墙体受剪承载力计算是为了防止以下何种破坏？（ ）",[585,587,589,591],{"key":20,"text":586,"correct":22},"斜拉破坏",{"key":24,"text":588,"correct":32},"斜压破坏",{"key":27,"text":590,"correct":22},"劈裂破坏",{"key":30,"text":592,"correct":22},"剪压破坏",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":27,"analysis":33},929251,"已知砖砌平拱过梁的构造高度为240mm，底面以上墙体高度为500mm，墙厚240mm，过梁净跨ln=1.2m，采用MU10烧结普通砖和M2.5混合砂浆砌筑，则该过梁能承受的均布荷载最接近于（ ）kN\u002Fm。",[597,599,601,603],{"key":20,"text":598,"correct":22},"11.73",{"key":24,"text":600,"correct":22},"8.53",{"key":27,"text":602,"correct":32},"6.04",{"key":30,"text":604,"correct":22},"2.84",[606,609,612,615,618,621],{"id":15,"name":607,"category":7,"favorite":608},"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":15},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]