[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-600-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":563},{"id":5,"name":6,"category":7,"favorite":8},600,"(结构) 专业考试一级","建筑工程",0,12,50,1330,[13,34,42,54,62,74,86,98,106,118,130,140,152,164,175,187,198,209,221,229,241,252,260,268,280,288,300,312,324,336,348,356,368,376,386,397,409,419,430,442,454,466,478,487,498,505,516,527,539,551],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},929102,1,"单选题","混凝土小型空心砌块砌体墙长1.6m，厚度为190mm，其上的永久荷载作用的正压力设计值N=135kN，水平推力设计值Y=25kN，永久荷载起控制作用，砌块墙采用MU10砌块，Mb5混合砂浆砌筑。则该墙体的受剪承载力最接近于（ ）kN。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","49.2",false,{"key":24,"text":25,"correct":22},"B","46.8",{"key":27,"text":28,"correct":29},"C","37.1",true,{"key":31,"text":32,"correct":22},"D","35.5","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},929103,"混凝土小型空心砌块砌体墙长1.6m，厚度为190mm，其上的永久荷载作用的正压力N=135kN，水平推力Y=25kN，永久荷载起控制作用，砌块墙采用MU10砌块，Mb5混合砂浆砌筑。则该墙体的受剪承载力最接近于( )kN。",[38,39,40,41],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":29},{"key":31,"text":32,"correct":22},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":24,"analysis":33},929104,"关于网状配筋砖砌体，下列论述不正确的是（ ）。",[46,48,50,52],{"key":20,"text":47,"correct":22},"网状配筋砖砌体开裂荷载，一般为破坏荷载的60%～75%",{"key":24,"text":49,"correct":29},"网状配筋砖砌体的破坏特点是形成贯通的竖向裂缝",{"key":27,"text":51,"correct":22},"网状配筋砖砌体当配筋量增加到一定程度，砌体强度接近于单砖抗压强度",{"key":31,"text":53,"correct":22},"网状配筋砖砌体的极限压缩变形可为相应的无筋砌体的2～3倍",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":24,"analysis":33},929105,"关于网状配筋砖砌体，下列论述不正确的是( )。",[58,59,60,61],{"key":20,"text":47,"correct":22},{"key":24,"text":49,"correct":29},{"key":27,"text":51,"correct":22},{"key":31,"text":53,"correct":22},{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":27,"analysis":33},929106,"关于砌体房屋静力计算方案的论述，下列各项中不正确的是( )。",[66,68,70,72],{"key":20,"text":67,"correct":22},"弹性方案房屋按屋架(大梁)与墙(柱)铰接的平面排架或框架计算",{"key":24,"text":69,"correct":22},"刚弹性方案房屋按屋架(大梁)与墙(柱)铰接考虑空间工作的平面排架或框架计算",{"key":27,"text":71,"correct":29},"刚性方案房屋在竖向荷载作用下，墙(柱)在每层高度范围内可近似看作两端铰支的竖向构件",{"key":31,"text":73,"correct":22},"多层刚性方案房屋在水平荷载作用下，墙(柱)可视为竖向连续梁",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":27,"analysis":33},929107,"关于砌体房屋静力计算方案，下列说法不正确的是（ ）。",[78,80,82,84],{"key":20,"text":79,"correct":22},"弹性方案房屋按屋架（大梁）与墙（柱）铰接的平面排架或框架计算",{"key":24,"text":81,"correct":22},"刚弹性方案房屋按屋架（大梁）与墙（柱）铰接考虑空间工作的平面排架或框架计算",{"key":27,"text":83,"correct":29},"刚性方案房屋在竖向荷载作用下，墙（柱）在每层高度范围内可近似看作两端铰支的竖向构件",{"key":31,"text":85,"correct":22},"多层刚性方案房屋在水平荷载作用下，墙（柱）可视为竖向连续梁",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":31,"analysis":33},929108,"关于配筋砌块抗震墙房屋的抗震墙布置，下列选项错误的是( )。",[90,92,94,96],{"key":20,"text":91,"correct":22},"为使抗震墙有较好的变形能力，控制每个墙段的高宽比不宜小于2",{"key":24,"text":93,"correct":22},"利用分洞将较长的配筋砌块抗震墙分成若干墙段时，墙段不宜小于1.0m",{"key":27,"text":95,"correct":22},"为使地震作用传递更直接，房屋的纵.横两方向的墙体，沿竖向上下连续贯通",{"key":31,"text":97,"correct":29},"为了保证楼.屋盖传递水平地震作用，8度区.抗震横墙的最大间距为15m",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":31,"analysis":33},929109,"关于配筋砌块抗震墙房屋的抗震墙布置，下列说法错误的是（ ）。",[102,103,104,105],{"key":20,"text":91,"correct":22},{"key":24,"text":93,"correct":22},{"key":27,"text":95,"correct":22},{"key":31,"text":97,"correct":29},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":27,"analysis":33},929110,"各层的地震剪力V、墙体正应力σ0见表4-5。验算④轴墙体截面抗震承载力哪一层不满足要求 ( )",[110,112,114,116],{"key":20,"text":111,"correct":22},"四层",{"key":24,"text":113,"correct":22},"三层",{"key":27,"text":115,"correct":29},"二层",{"key":31,"text":117,"correct":22},"一层",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},929111,"非抗震设防区某四层教学楼局部平面如图所示。各层平面布置相同，各层层高均为3.6m。楼、屋盖均为现浇钢筋混凝土板，静力计算方案为刚性方案。墙体为网状配筋砖砌体，采用MU10级烧结普通砖，M10级水泥砂浆砌筑，钢筋网采用乙级冷拔低碳钢丝 方格钢筋网间距为40mm，网的竖向间距130mm。纵横墙厚度均为240mm，砌体施工质量控制等级为B级。第二层窗间墙A的轴向力偏心距e=24mm。[2012年真题] 3.假定，墙体中无配筋，β=15，修正后的墙体抗压强度设计值f=1.68N\u002Fmm2。试问，第二层窗间墙A的受压承载力设计值（kN）与下列何项数值最为接近？（ ） 提示：按单向偏心受压构件计算。",[122,124,126,128],{"key":20,"text":123,"correct":22},"430",{"key":24,"text":125,"correct":22},"290",{"key":27,"text":127,"correct":29},"260",{"key":31,"text":129,"correct":22},"210",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},929112,"非抗震设防区某四层教学楼局部平面如图所示。各层平面布置相同，各层层高均为3.6m。楼、屋盖均为现浇钢筋混凝土板，静力计算方案为刚性方案。墙体为网状配筋砖砌体，采用MU10级烧结普通砖，M10级水泥砂浆砌筑，钢筋网采用乙级冷拔低碳钢丝 方格钢筋网间距为40mm，网的竖向间距130mm。纵横墙厚度均为240mm，砌体施工质量控制等级为B级。第二层窗间墙A的轴向力偏心距e=24mm。[2012年真题]",[134,135,137,139],{"key":20,"text":33,"correct":22},{"key":24,"text":136,"correct":22},"2.假定，墙体体积配筋百分率ρ=0.6。试问，第二层窗间墙A的受压承载力设计值（kN）与下列何项数值最为接近？（ ）",{"key":27,"text":138,"correct":29},"提示：窗间墙A的承载力影响系数为ψn。",{"key":31,"text":33,"correct":22},{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":24,"analysis":33},929113,"非抗震设防区某四层教学楼局部平面如图所示。各层平面布置相同，各层层高均为3.6m。楼、屋盖均为现浇钢筋混凝土板，静力计算方案为刚性方案。墙体为网状配筋砖砌体，采用MU10级烧结普通砖，M10级水泥砂浆砌筑，钢筋网采用乙级冷拔低碳钢丝 方格钢筋网间距为40mm，网的竖向间距130mm。纵横墙厚度均为240mm，砌体施工质量控制等级为B级。第二层窗间墙A的轴向力偏心距e=24mm。[2012年真题] 1.试问，第二层窗间墙A的网状配筋砖砌体受压构件的稳定系数 与下列何项数值最为接近？（ ） 提示：房屋横墙间距s=10800mm。",[144,146,148,150],{"key":20,"text":145,"correct":22},"0.45",{"key":24,"text":147,"correct":29},"0.55",{"key":27,"text":149,"correct":22},"0.65",{"key":31,"text":151,"correct":22},"0.75",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":31,"analysis":33},929114,"方案初期，某四层砌体结构房屋顶层局部平面布置图如图所示，层高均为3.6m。墙体采用MU10级烧结多孔砖、M5级混合砂浆砌筑。墙厚为240mm。屋面板为预制预应力空心板上浇钢筋混凝土叠合层，屋面板总厚度为300mm，简支在①轴和②轴墙体上，支承长度为120mm。屋面永久荷载标准值为12kN／m2，活荷载标准值为0.5kN／m2。砌体施工质量控制等级为B级；抗震设防烈度为7度，设计基本地震加速度为0.1g。[2013年真题] 5.试问，突出屋面的楼梯间最少应设置的构造柱数量，与下列何项数值最为接近？（ ）",[156,158,160,162],{"key":20,"text":157,"correct":22},"2",{"key":24,"text":159,"correct":22},"4",{"key":27,"text":161,"correct":22},"6",{"key":31,"text":163,"correct":29},"8",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":27,"analysis":33},929115,"方案初期，某四层砌体结构房屋顶层局部平面布置图如图所示，层高均为3.6m。墙体采用MU10级烧结多孔砖、M5级混合砂浆砌筑。墙厚为240mm。屋面板为预制预应力空心板上浇钢筋混凝土叠合层，屋面板总厚度为300mm，简支在①轴和②轴墙体上，支承长度为120mm。屋面永久荷载标准值为12kN／m2，活荷载标准值为0.5kN／m2。砌体施工质量控制等级为B级；抗震设防烈度为7度，设计基本地震加速度为0.1g。[2013年真题] 4.假定，将①轴墙体设计为砖砌体和钢筋混凝土构造柱组成的组合墙。试问，①轴墙体内最少应设置的构造柱数量，与下列何项数值最为接近？（ ） 提示：按《砌体结构设计规范》（GB 50003—2011）作答。",[168,169,171,173],{"key":20,"text":157,"correct":22},{"key":24,"text":170,"correct":22},"3",{"key":27,"text":172,"correct":29},"5",{"key":31,"text":174,"correct":22},"7",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":20,"analysis":33},929116,"方案初期，某四层砌体结构房屋顶层局部平面布置图如图所示，层高均为3.6m。墙体采用MU10级烧结多孔砖、M5级混合砂浆砌筑。墙厚为240mm。屋面板为预制预应力空心板上浇钢筋混凝土叠合层，屋面板总厚度为300mm，简支在①轴和②轴墙体上，支承长度为120mm。屋面永久荷载标准值为12kN／m2，活荷载标准值为0.5kN／m2。砌体施工质量控制等级为B级；抗震设防烈度为7度，设计基本地震加速度为0.1g。[2013年真题] 3.试问，为提高顶层①轴墙体上端的受压承载力，下列哪种方法不可行？（ ）",[179,181,183,185],{"key":20,"text":180,"correct":29},"①轴墙体采用网状配筋砖砌体",{"key":24,"text":182,"correct":22},"①轴墙体采用砖砌体和钢筋砂浆面层的组合砌体",{"key":27,"text":184,"correct":22},"增加屋面板的支承长度",{"key":31,"text":186,"correct":22},"提高砌筑砂浆的强度等级至M10",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":31,"analysis":33},929117,"方案初期，某四层砌体结构房屋顶层局部平面布置图如图所示，层高均为3.6m。墙体采用MU10级烧结多孔砖、M5级混合砂浆砌筑。墙厚为240mm。屋面板为预制预应力空心板上浇钢筋混凝土叠合层，屋面板总厚度为300mm，简支在①轴和②轴墙体上，支承长度为120mm。屋面永久荷载标准值为12kN／m2，活荷载标准值为0.5kN／m2。砌体施工质量控制等级为B级；抗震设防烈度为7度，设计基本地震加速度为0.1g。[2013年真题] 2.试问，顶层①轴每延米墙体下端受压承载力设计值N（kN／m），与下列何项数值最为接近？（ ） 提示：不考虑下层弯矩对本层墙体的影响，不考虑风荷载。",[191,193,195,197],{"key":20,"text":192,"correct":22},"120",{"key":24,"text":194,"correct":22},"150",{"key":27,"text":196,"correct":22},"180",{"key":31,"text":127,"correct":29},{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},929118,"方案初期，某四层砌体结构房屋顶层局部平面布置图如图所示，层高均为3.6m。墙体采用MU10级烧结多孔砖、M5级混合砂浆砌筑。墙厚为240mm。屋面板为预制预应力空心板上浇钢筋混凝土叠合层，屋面板总厚度为300mm，简支在①轴和②轴墙体上，支承长度为120mm。屋面永久荷载标准值为12kN／m2，活荷载标准值为0.5kN／m2。砌体施工质量控制等级为B级；抗震设防烈度为7度，设计基本地震加速度为0.1g。[2013年真题] 1.试问，顶层①轴每延米墙体的局部受压承载力设计值Nl（kN／m），与下列何项数值最为接近？（ ） 提示：多孔砖砌体孔洞未灌实。",[202,203,205,207],{"key":20,"text":196,"correct":29},{"key":24,"text":204,"correct":22},"240",{"key":27,"text":206,"correct":22},"360",{"key":31,"text":208,"correct":22},"480",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":31,"analysis":33},929119,"多层砌体刚性方案房屋，在水平风荷载作用下对纵墙进行内力分析时，下列论述不可能出现的是（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":22},"可按竖向连续梁分析内力",{"key":24,"text":216,"correct":22},"纵墙上.下端的弯矩可按两端固定梁计算",{"key":27,"text":218,"correct":22},"满足规范的规定，则可不进行风力计算",{"key":31,"text":220,"correct":29},"在一般刚性方案房屋中，必须考虑墙内由风荷载引起的弯曲应力以及在纵墙内产生的附加压力",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":31,"analysis":33},929120,"多层砌体刚性方案房屋，在水平风荷载作用下对纵墙进行内力分析时，下列论述不可能出现的是( )。",[225,226,227,228],{"key":20,"text":214,"correct":22},{"key":24,"text":216,"correct":22},{"key":27,"text":218,"correct":22},{"key":31,"text":220,"correct":29},{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":20,"analysis":33},929121,"对带壁柱墙的计算截面翼缘宽度bf取值，下列规定哪一项是不正确的？（ ）[2011年真题]",[233,235,237,239],{"key":20,"text":234,"correct":29},"多层房屋无门窗洞口时，bf取相邻壁柱间的距离",{"key":24,"text":236,"correct":22},"单层房屋，bf=b+2\u002F3H（b为壁柱宽度，Ⅳ为壁柱墙高度），但不大于窗间墙宽度和相邻壁柱间距离",{"key":27,"text":238,"correct":22},"多层房屋有门窗洞口时，bf可取窗间墙宽度",{"key":31,"text":240,"correct":22},"计算带壁柱墙的条形基础时，bf取相邻壁柱间的距离",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":20,"analysis":33},929122,"对带壁柱墙的承载力验算时，计算截面的翼缘宽度bf，按下列规定采用时，不正确的情况是（ ）。",[245,246,248,250],{"key":20,"text":234,"correct":29},{"key":24,"text":247,"correct":22},"多层房屋有门窗洞口时，bf取窗间墙的宽度",{"key":27,"text":249,"correct":22},"单层房屋，bf=b+2H\u002F3（b为壁柱宽度，H为墙高），但不大于窗间墙宽度和相邻壁柱间的距离",{"key":31,"text":251,"correct":22},"计算带壁墙的条形基础时，bf取相邻壁柱间的距离",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":20,"analysis":33},929123,"对带壁柱墙的承载力验算时，计算截面的翼缘宽度bf，按下列规定采用时，不正确的情况是( )。",[256,257,258,259],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":31,"analysis":33},929124,"对不同墙体进行抗震承载力验算时，需采用不同的承载力抗震调整系数。假定构件受力状态均为受剪，试问，下列哪一种墙体承载力抗震调整系数yRE不符合规范要求？（ ）[2012年真题] 提示：按《砌体结构设计规范》（GB 50003—2011）作答。",[264,265,266,267],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":27,"analysis":33},929125,"承重墙梁在顶部荷载作用下，下列破坏形态不可能发生的是（ ）。",[272,274,276,278],{"key":20,"text":273,"correct":22},"托梁纵向钢筋屈服而发生的正截面破坏",{"key":24,"text":275,"correct":22},"墙体或托梁斜截面抗剪承载力不足而发生的斜截面破坏",{"key":27,"text":277,"correct":29},"墙梁上部受压区砌体因抗压强度不足而发生的正截面破坏",{"key":31,"text":279,"correct":22},"托梁支座上部砌体被压碎的局部受压破坏",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":27,"analysis":33},929126,"承重墙梁在顶部荷载作用下，下列破坏形态不可能发生的是( )。",[284,285,286,287],{"key":20,"text":273,"correct":22},{"key":24,"text":275,"correct":22},{"key":27,"text":277,"correct":29},{"key":31,"text":279,"correct":22},{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":31,"analysis":33},929127,"承重墙梁，各部分尺寸见图及表，托梁混凝土强度等级为C20，纵向受力钢筋采用HRB335，砖强度为MU10，水泥砂浆强度等级采用M5，荷载设计值Q1=23.8kN\u002Fm，Q2=116kN\u002Fm。 4.该墙梁的墙体受剪承载力最接近于（ ）kN。",[292,294,296,298],{"key":20,"text":293,"correct":22},"139.8",{"key":24,"text":295,"correct":22},"145.6",{"key":27,"text":297,"correct":22},"150.5",{"key":31,"text":299,"correct":29},"179.5",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":33},929128,"承重墙梁，各部分尺寸见图及表，托梁混凝土强度等级为C20，纵向受力钢筋采用HRB335，砖强度为MU10，水泥砂浆强度等级采用M5，荷载设计值Q1=23.8kN\u002Fm，Q2=116kN\u002Fm。 3.计算弯矩系数αM=0.450，计算轴力系数ηN=1.450，则托梁跨中截面的弯矩Mb和轴心拉力Nb与下列（ ）组数据最为接近。",[304,306,308,310],{"key":20,"text":305,"correct":29},"347.7kN·m；238.6kN",{"key":24,"text":307,"correct":22},"354.27kN·m；239.7kN",{"key":27,"text":309,"correct":22},"365kN·m；245.6kN",{"key":31,"text":311,"correct":22},"372.35kN·m；318.92kN",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":24,"analysis":33},929129,"承重墙梁，各部分尺寸见图及表，托梁混凝土强度等级为C20，纵向受力钢筋采用HRB335，砖强度为MU10，水泥砂浆强度等级采用M5，荷载设计值Q1=23.8kN\u002Fm，Q2=116kN\u002Fm。 2.计算弯矩系数αM与计算轴力系数ηN与下列（ ）组数据最为接近。",[316,318,320,322],{"key":20,"text":317,"correct":22},"αM=0.406；ηN=1.430",{"key":24,"text":319,"correct":29},"αM=0.432；ηN=1.430",{"key":27,"text":321,"correct":22},"αM=0.450；ηN=1.250",{"key":31,"text":323,"correct":22},"αM=0.485；ηN=1.336",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":31,"analysis":33},929130,"承重墙梁，各部分尺寸见图及表，托梁混凝土强度等级为C20，纵向受力钢筋采用HRB335，砖强度为MU10，水泥砂浆强度等级采用M5，荷载设计值Q1=23.8kN\u002Fm，Q2=116kN\u002Fm。 1.已知墙梁的计算跨度L0=6.05m，墙体计算高度hw=2.85m，则该构件可以按墙梁计算的洞口高度hh和宽度bh的限制值最接近于（ ）。",[328,330,332,334],{"key":20,"text":329,"correct":22},"bh＜1.550m；hh＜2.375m",{"key":24,"text":331,"correct":22},"bh＜1.750m；hh＜2.375m",{"key":27,"text":333,"correct":22},"bh＜1.750m；hh＜2.450m",{"key":31,"text":335,"correct":29},"bh＜1.815m；hh＜2.450m",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":24,"analysis":33},929131,"8度区，多层砖砌体房屋与底部框架多层砖房，最小墙厚均为240mm时，下列哪一项说法是正确的？（ ）",[340,342,344,346],{"key":20,"text":341,"correct":22},"房屋总高度和层数，多层砖砌体房屋与底部框架多层砖房均相同",{"key":24,"text":343,"correct":29},"房屋最大高宽比，多层砖砌体房屋小于底部框架多层房屋",{"key":27,"text":345,"correct":22},"房屋抗震横墙的最大间距，两者是相同的",{"key":31,"text":347,"correct":22},"房屋层高，多层砖砌体房屋与底部框架的多层房屋层高限值相同",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":24,"analysis":33},929132,"8度区，多层砖砌体房屋与底部框架多层砖房，最小墙厚均为240mm时，下列哪一项说法是正确的 ( )",[352,353,354,355],{"key":20,"text":341,"correct":22},{"key":24,"text":343,"correct":29},{"key":27,"text":345,"correct":22},{"key":31,"text":347,"correct":22},{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":24,"analysis":33},929133,"7度区配筋砌块砌体剪力墙房屋，高度25m，剪力墙长4000mm、高2800mm、宽190mm，墙体承受弯矩设计值M=490kN·m、轴力设计值N=600kN、剪力设计值V=175kN，墙体采用MU10砌块、孔洞率46%、Mb10砂浆、Cb20灌孔混凝土、灌孔率33%，as=300mm。不考虑水平钢筋时，墙体的抗剪承载力最接近于（ ）kN。",[360,362,364,366],{"key":20,"text":361,"correct":22},"193",{"key":24,"text":363,"correct":29},"227",{"key":27,"text":365,"correct":22},"233",{"key":31,"text":367,"correct":22},"885",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":24,"analysis":33},929134,"7度区配筋砌块砌体剪力墙房屋，高度25m，剪力墙长4000mm、高2800mm、宽190mm，墙体承受弯矩设计值M=490kN·m、轴力设计值N=600kN、剪力设计值V=175kN，墙体采用MU10砌块、孔洞率46%、Mb10砂浆、Cb20灌孔混凝土、灌孔率33%，as=300mm。不考虑水平钢筋时，墙体的抗剪承载力最接近于( )kN。",[372,373,374,375],{"key":20,"text":361,"correct":22},{"key":24,"text":363,"correct":29},{"key":27,"text":365,"correct":22},{"key":31,"text":367,"correct":22},{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":378,"answer":31,"analysis":33},929135,[379,381,383,385],{"key":20,"text":380,"correct":22},"190",{"key":24,"text":382,"correct":22},"200",{"key":27,"text":384,"correct":22},"220",{"key":31,"text":204,"correct":29},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":24,"analysis":33},929136,"5.假定，将砖抗震墙ZQ改为钢筋混凝土抗震墙，且混凝土抗震墙（包括端柱）的抗侧刚度为 作用于底层顶标高处的横向地震剪力设计值V=1000kN。试问，作用于每个框架柱KZ上的地震剪力设计值VKZ（kN），与下列何项数值最为接近？（ ）",[390,391,393,395],{"key":20,"text":159,"correct":22},{"key":24,"text":392,"correct":29},"10",{"key":27,"text":394,"correct":22},"20",{"key":31,"text":396,"correct":22},"30",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":31,"analysis":33},929137,"4.假定，框架柱上下端的正截面受弯承载力设计值均为200kN·m；砖抗震墙的实际截面面积为1.2m2，抗震抗剪强度设计值fvE为0.2MPa；框架梁的高度为0.6m。试问，由砖抗震墙和两端框架柱组成的组合截面的抗震受剪承载力设计值（kN），与下列何项数值最为接近？（ ）",[401,403,405,407],{"key":20,"text":402,"correct":22},"350",{"key":24,"text":404,"correct":22},"450",{"key":27,"text":406,"correct":22},"550",{"key":31,"text":408,"correct":29},"650",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":24,"analysis":33},929138,"3.假定，作用于每道横向砖抗震墙ZQ上的地震剪力设计值Vw=400kN。试问，由砖抗震墙引起的与其相连的框架柱附加轴力设计值（kN），与下列何项数值最为接近？（ ）",[413,414,415,417],{"key":20,"text":382,"correct":22},{"key":24,"text":127,"correct":29},{"key":27,"text":416,"correct":22},"400",{"key":31,"text":418,"correct":22},"560",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},929139,"2.若荷载效应的基本组合由永久荷载效应控制，活荷载的组合系数ψc=0.7，试问，使用阶段墙梁顶面的荷载设计值Q2(kN\u002Fm)，与下列何项数值最为接近？（ ）",[423,425,427,428],{"key":20,"text":424,"correct":22},"140",{"key":24,"text":426,"correct":29},"130",{"key":27,"text":192,"correct":22},{"key":31,"text":429,"correct":22},"115",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":31,"analysis":33},929140,"2.假定作用于底层顶标高处的横向地震剪力设计值V=1000kN。试问，作用于每个框架柱KZ上的地震剪力设计值V（kN），与下列何项数值最为接近？（ ）",[434,436,438,440],{"key":20,"text":435,"correct":22},"14",{"key":24,"text":437,"correct":22},"18",{"key":27,"text":439,"correct":22},"22",{"key":31,"text":441,"correct":29},"25",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":33},929141,"2.假定，在楼层挑梁上部墙内无门洞。试问，楼层挑梁的承载力计算时，其最大弯矩设计值Mmax(kN·m)、最大剪力设计值Vmax(kN)，与下列何项数值最为接近？（ ）",[446,448,450,452],{"key":20,"text":447,"correct":22},"65，60",{"key":24,"text":449,"correct":29},"72，60",{"key":27,"text":451,"correct":22},"65，63",{"key":31,"text":453,"correct":22},"72，63",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":31,"analysis":33},929142,"1.试问，该墙梁跨中截面的计算高度H0与下何项数值最为接近？（ ）",[458,460,462,464],{"key":20,"text":459,"correct":22},"6.0",{"key":24,"text":461,"correct":22},"4.5",{"key":27,"text":463,"correct":22},"3.5",{"key":31,"text":465,"correct":29},"3.1",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":20,"analysis":33},929143,"1.楼层挑梁下砌体的局部受压承载力验算时，试问，公式N1(kN)≤ηγfA1（kN）的左右端项，与下列何项数值最为接近？（ ） 提示：砌体的抗压强度设计值不考虑强度调整系数γa的影响。",[470,472,474,476],{"key":20,"text":471,"correct":29},"120＜200",{"key":24,"text":473,"correct":22},"100＜200",{"key":27,"text":475,"correct":22},"120＜170",{"key":31,"text":477,"correct":22},"100＜170",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":20,"analysis":33},929144,"1.假定，作用于底层顶标高处的横向地震剪力标准值Vk=800kN。试问，作用于每道横向砖抗震墙ZQ上的地震剪力设计值（kN），与下列何项数值最为接近？（ ）",[482,483,485,486],{"key":20,"text":206,"correct":29},{"key":24,"text":484,"correct":22},"280",{"key":27,"text":127,"correct":22},{"key":31,"text":382,"correct":22},{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":489,"answer":27,"analysis":33},929145,[490,492,494,496],{"key":20,"text":491,"correct":22},"853.0",{"key":24,"text":493,"correct":22},"873.4",{"key":27,"text":495,"correct":29},"885.6",{"key":31,"text":497,"correct":22},"913.2",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":500,"answer":31,"analysis":33},929146,[501,502,503,504],{"key":20,"text":170,"correct":22},{"key":24,"text":159,"correct":22},{"key":27,"text":172,"correct":22},{"key":31,"text":161,"correct":29},{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":507,"answer":24,"analysis":33},929147,[508,510,512,514],{"key":20,"text":509,"correct":22},"构件高厚比β的影响",{"key":24,"text":511,"correct":29},"综合考虑构件高厚比β和轴向力偏心距e的影响",{"key":27,"text":513,"correct":22},"施工偏差的影响",{"key":31,"text":515,"correct":22},"综合考虑了所有对砌体受压承载力的影响因素",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":518,"answer":31,"analysis":33},929148,[519,521,523,525],{"key":20,"text":520,"correct":22},"920.4",{"key":24,"text":522,"correct":22},"902.1",{"key":27,"text":524,"correct":22},"893.6",{"key":31,"text":526,"correct":29},"877.0",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":20,"analysis":33},929149,"有吊车的单层单跨砖砌体排架厂房，已知H=8.5m，Hu=3.0m，Iu=0.88×1010mm4，Il=4.806×1010mm4，设为刚弹性方案房屋。当荷载组合不考虑吊车作用时，变截面柱上段计算高度Hu0和变截面柱下段计算高度Hl0为下列何组数值？（ ）",[531,533,535,537],{"key":20,"text":532,"correct":29},"排架方向：Hu0=6m，Hl0=10.2m",{"key":24,"text":534,"correct":22},"排架方向：Hu0=7.5m，Hl0=12.75m",{"key":27,"text":536,"correct":22},"排架方向：Hu0=6m，Hl0=12.7m",{"key":31,"text":538,"correct":22},"排架方向：Hu0=6m，Hl0=8.22m",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":20,"analysis":33},929150,"一新疆落叶松（TC13 A）方木压弯构件（干材），设计使用年限为50年，截面尺寸为150mm×150mm，长度l=2500mm。两端铰接，承受压力设计值（轴心）N=50kN，最大初始弯矩设计值Mo=4.0kN·m。[2011年真题] 2.试问，考虑轴压力和弯矩共同作用下的构件折减系数ψm与下列何项数值最为接近？（ ）",[543,545,547,549],{"key":20,"text":544,"correct":29},"0.42",{"key":24,"text":546,"correct":22},"0.38",{"key":27,"text":548,"correct":22},"0.27",{"key":31,"text":550,"correct":22},"0.23",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":31,"analysis":33},929151,"一新疆落叶松（TC13 A）方木压弯构件（干材），设计使用年限为50年，截面尺寸为150mm×150mm，长度l=2500mm。两端铰接，承受压力设计值（轴心）N=50kN，最大初始弯矩设计值Mo=4.0kN·m。[2011年真题] 1.试问，该构件仅考虑轴心受压时的稳定系数，与下列何项数值最为接近？提示：该构件截面的回转半径i=43.3mm。（ ）",[555,557,559,561],{"key":20,"text":556,"correct":22},"0.90",{"key":24,"text":558,"correct":22},"0.84",{"key":27,"text":560,"correct":22},"0.66",{"key":31,"text":562,"correct":29},"0.52",[564,567,570,573,576,579],{"id":15,"name":565,"category":7,"favorite":566},"领导干部任职前廉政法规知识测试题",92,{"id":568,"name":569,"category":7,"favorite":15},595,"建筑结构与设备",{"id":571,"name":572,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":574,"name":575,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":577,"name":578,"category":7,"favorite":8},534,"BIM工程师",{"id":580,"name":578,"category":7,"favorite":8},535]