[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929806":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},929806,600,1,"单选题","今有一在非地震区的办公楼顶层柱。经计算，已知在永久荷载标准值、屋面活荷载（上人屋面）标准值、风荷载标准值及雪荷载标准值分别作用下得其柱的轴向力为NGk=40kN、NQ1k=12kN、NQ2k=4kN和NQ3k=1kN。其中：NGk为永久荷载标准值所引起的该柱轴向压力标准值；NQ1k为屋面活荷载标准值所引起的该柱轴向压力标准值；NQ2k为风荷载标准值所引起的该柱轴向压力标准值；NQ3k为雪荷载标准值所引起的该柱轴向压力标准值。 对办公楼顶层柱作正常使用极限状态准永久组合时，其轴压力设计值N最接近于（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","44.80",true,{"key":16,"text":17,"correct":18},"B","46.00",false,{"key":20,"text":21,"correct":18},"C","48.20",{"key":23,"text":24,"correct":18},"D","52.70","根据《建筑结构荷载规范》（GB 50009—2012）第5.3.1条可知，屋面活载不与雪载同时考虑，取较大值参与组合；又根据第8.1.4条规定，风荷载的准永久值系数为0；查表5.3.1可得，上人屋面活载的准永久值系数ψq=0.4；则由式（3.2.10）计算，轴压力设计值为：N=NGk+ψqNQ1k=40+0.4×12=44.80kN。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]