[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929796":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},929796,600,1,"单选题","某大底盘单塔楼高层建筑，主楼为钢筋混凝土框架—核心筒，裙房为混凝土框架—剪力墙结构，主楼与裙楼连为整体，如图6-28所示。抗震设防烈度7度，建筑抗震设防类别为丙类，设计基本地震加速度为0.15g，场地Ⅲ类，采用桩筏形基础。 裙房一榀横向框架距主楼18m，某一顶层中柱上、下端截面组合弯矩设计值分别为 320kN·m，350kN·m（同为顺时针方向）；剪力计算值为125kN，柱断面为500mm×500mm，Hn=5.2m，>2，混凝土强度等级C40。在不采用有利于提高轴压比限值的构造措施的条件下，试问，该柱截面设计时，轴压比限值[μn]及剪力设计值（kN）应取下列何组数值才能满足规范的要求？（ ） 提示：按《建筑抗震设计规范》（GB 50011—2010）作答；V=ηvc（Mcb+Mct）\u002FHn。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","0.90；125",false,{"key":16,"text":17,"correct":14},"B","0.75；170",{"key":19,"text":20,"correct":14},"C","0.85；155",{"key":22,"text":23,"correct":24},"D","0.75；155",true,"",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]