[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929786":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},929786,600,1,"单选题","某普通办公楼，采用现浇钢筋混凝土框架—核心筒结构，房屋高度116.3m，地上31层，地下2层，3层设转换层，采用桁架转换构件，平、剖面如图6-15所示。抗震设防烈度为7度（0.1g），丙类建筑，设计地震分组第二组，Ⅱ类建筑场地，地下室顶板±0.000处作为上部结构嵌固部位。 .假定，振型分解反应谱法求得的2～4层的水平地震剪力标准值（Vi）及相应层间位移值（△i）见表6-9。在P=1000kN水平力的作用下，按图6-16模型计算的位移分别为：△1=7.8mm；△2=6.2mm。试问，进行结构竖向规则性判断时，宜取下列哪种方法及结果作为结构竖向不规则的判断依据？（ ） 提示：3层转换层按整层计。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","等效剪切刚度比验算方法，侧向刚度比不满足要求",false,{"key":16,"text":17,"correct":18},"B","楼层侧向刚度比验算方法，侧向刚度比不满足规范要求",true,{"key":20,"text":21,"correct":14},"C","考虑层高修正的楼层侧向刚度比验算方法，侧向刚度比不满足规范要求",{"key":23,"text":24,"correct":14},"D","等效侧向刚度比验算方法，等效刚度比不满足规范要求","",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]