[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929782":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},929782,600,1,"单选题","某16层现浇钢筋混凝土框架-剪力墙结构办公楼，房屋高度为64.3m，如图6-9所示，楼板无削弱。抗震设防烈度为8度，丙类建筑，Ⅱ类建筑场地。假定，方案比较时，发现X、Y方向每向可以减少两片剪力墙（减墙后结构承载力及刚度满足规范要求）。试问，如果仅从结构布置合理性考虑，下列四种减墙方案中哪种方案相对合理？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","X向：W1；Y向：W5",false,{"key":16,"text":17,"correct":14},"B","X向：W2；Y向：W6",{"key":19,"text":20,"correct":21},"C","X向：W3；Y向：W4",true,{"key":23,"text":24,"correct":14},"D","X向：W2；Y向：W7","该结构为长矩形平面，根据《高层建筑混凝土结构技术规程》（JGJ 3—2010）第8.1.8条第2款规定，X向剪力墙不宜集中布置在房屋的两尽端，宜减W1或W3墙。根据第8.1.8条第1款规定，Y向剪力墙间距不宜大于3B=45m及40m之较小者40m，宜减W4或W7。综合上述原因，同时考虑框架-剪力墙结构中剪力墙的布置原则，C项方案相对合理。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]