[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929755":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},929755,600,1,"单选题","某底层带托柱转换层的钢筋混凝土框架—筒体结构办公楼，地下1层，地上25层，地下1层层高6.0m，地上1层至2层的层高均为4.5m，其余各层层高均为3.3m，房屋高度为85.2m，转换层位于地上2层，见图6-20所示。抗震设防烈度为7度，设计基本地震加速度为0.10g，设计分组为第一组，丙类建筑，Ⅲ类场地，混凝土强度等级：地上2层及以下均为C50，地上3层至5层为C40，其余各层均为C35。 假定，地上第2层转换梁的抗震等级为一级，某转换梁截面尺寸为700mm×1400mm，经计算求得梁端截面弯矩标准值（kN·m）如下：恒载Mgk=1304；活载（按等效均布荷载计）Mqk=169；风载Mwk=135；水平地震作用MEhk=300。试问，在进行梁端截面设计时，梁端考虑水平地震作用组合时的弯矩设计值M（kN·m）与下列何项数值最为接近？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","2100",false,{"key":16,"text":17,"correct":14},"B","2200",{"key":19,"text":20,"correct":21},"C","2350",true,{"key":23,"text":24,"correct":14},"D","2450","",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]