[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929739":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},929739,600,1,"单选题","底层某双肢剪力墙如图6-14所示。假定，墙肢1在横向正、反向水平地震作用下考虑地震作用组合的内力计算值见表6-7；墙肢2相应于墙肢1的正、反向考虑地震作用组合的内力计算值见表6-8。试问，墙肢2进行截面设计时，其相应于反向地震作用的内力设计值M（kN·m）、V（kN）、N（kN），应取下列何组数值？（ ） 提示：①剪力墙端部受压（拉）钢筋合力点到受压（拉）区边缘的距离as′=as=200mm。②不考虑翼缘，按矩形截面计算。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","5000、1600、14000",false,{"key":16,"text":17,"correct":14},"B","5000、2000、17500",{"key":19,"text":20,"correct":14},"C","6250、1600、17500",{"key":22,"text":23,"correct":24},"D","6250、2000、14000",true,"",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]