[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929675":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},929675,600,1,"单选题","关于柱轴压比限值的要求，下列各项不正确的是( )。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","框支剪力墙结构，抗震等级属于一级的框支柱(包括框支角柱)，其轴压比不宜大于0.60",false,{"key":16,"text":17,"correct":14},"B","框架一剪力墙结构，抗震等级属一级的框架柱，当剪力墙部分承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其框架柱轴压比不宜大于0.70",{"key":19,"text":20,"correct":14},"C","框架一核心筒结构，抗震等级属一级的框架柱，当核心筒结构承受的地震倾覆力矩大于结构总地震倾覆力矩的50%时，其框架柱轴压比不宜大于0.75",{"key":22,"text":23,"correct":24},"D","筒中筒结构，抗震等级属一级的密集柱，沿柱全高采用井字复合箍，箍筋间距 100mm.肢距150mm.箍径12mm；其内筒承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其密集柱的轴压比不宜大于0.75",true,"筒中筒结构的受力情况，在侧向荷载作用下与框架一剪力墙结构相类似。根据《高层建筑混凝土结构技术规范》(JGJ3-2002、J186-2002)表6.4.2，抗震等级属于一级的外筒密集柱轴压比限值可取0.75，但又因此柱全高均以箍距不大于100mm、肢距不大于200mm、箍径又不小于12mm的井字复合箍，根据注4，轴压比限值可增大0.10。故其轴压比限值宜为0.85。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]