[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929576":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},929576,600,1,"单选题","一幢20层的高层建筑，采用钢筋混凝土结构。该建筑的抗震设防烈度为8度(0.3g)，场地类别为Ⅱ类，设计地震分组为第一组。该结构的第一自振周期T1=1.2s，阻尼比ζ=0.05，地震影响系数α最接近于( )。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","0.08",true,{"key":16,"text":17,"correct":18},"B","0.07",false,{"key":20,"text":21,"correct":18},"C","0.06",{"key":23,"text":24,"correct":18},"D","0.05","该建筑抗震设防烈度为8度(0.3g)，按多遇地震计算水平地震作用时，查《建筑抗震设计规范》(GB 50011-2001)(2008年版)表5.1.4-1，水平地震影响系数最大值为：αmax=0.24；场地类别为Ⅱ类，设计地震分组为第一组，则查表5.1.4-2可知，特征周期Tg=0.35s。 混凝土结构的阻尼比ζ=0.05，则阻尼调整系数η2可根据式(5.1.5-3)计算，即：",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]