[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929529":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},929529,600,1,"单选题","某住宅用户进行二次装修，地面采用20mm水泥砂浆，然后在上面铺10mm厚大理石；而下家顶棚为V形钢龙骨吊顶，二层9mm纸面石膏板，无保温层；则增加楼面自重与楼面活荷载标准值的比值为（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","0.35",false,{"key":16,"text":17,"correct":18},"B","0.44",true,{"key":20,"text":21,"correct":14},"C","0.50",{"key":23,"text":24,"correct":14},"D","0.59","根据《建筑结构荷载规范》（GB 50009—2012）附录A表A可知，各项材料的规定自重为：大理石28kN\u002Fm3，水泥砂浆20kN\u002Fm3，V形轻钢龙骨吊顶（二层9mm纸面石膏板，无保温层）0.20kN\u002Fm3；则二次装修增加楼面自重分别为：10mm厚大理石0.28kN\u002Fm3（0.01\u002F1×28kN\u002Fm3），20mm厚水泥砂浆0.40kN\u002Fm3（0.02\u002F1×20kN\u002Fm3），V形轻钢龙骨吊顶0.20kN\u002Fm3，则二次装修增加楼面自重为0.28+0.4+0.2=0.88kN\u002Fm3；根据表5.1.1可知，住宅楼面活荷载标准值为2.0kN\u002Fm2，则该楼面二次装修增加楼面自重与楼面活荷载标准值的比值为0.88\u002F2.0=0.44。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]