[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929447":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},929447,600,1,"单选题","某工程采用打入式钢筋混凝土预制方桩，桩截面边长为400mm，单桩竖向抗压承载力特征值Ra=750kN。某柱下原设计布置 A、 B、C三桩，工程桩施工完毕后，检测发现B桩有严重缺陷，按废桩处理（桩顶与承台始终保持脱开状态），需要补打D桩，补桩后的桩基承台如图5-16所示。承台高度为1100mm，混凝土强度等级为C35（ft=1.57 N\u002Fmm2），柱截面尺寸为600mm×600mm。提示：按《建筑桩基技术规范》（JGJ 94—2008）作答，承台的有效高度h0按1050mm取用。 假定，补桩后，在荷载效应基本组合下，不计承台及其上土重，A桩和C桩承担的竖向反力设计值均为1100kN，D桩承担的竖向反力设计值为900kN。试问，通过承台形心至两腰边缘正交截面范围内板带的弯矩设计值M（kN·m），与下列何项数值最为接近？（ ）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","780",false,{"key":16,"text":17,"correct":18},"B","880",true,{"key":20,"text":21,"correct":14},"C","920",{"key":23,"text":24,"correct":14},"D","940","",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]