[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929434":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},929434,600,1,"单选题","某工程由两幢7层主楼及地下车库组成，统一设一层地下室，采用钢筋混凝土框架结构体系，桩基础。工程桩采用泥浆护壁旋挖成孔灌注桩，桩身纵筋锚入承台内800mm，主楼桩基础采用一柱一桩的布置形式，桩径800mm，有效桩长26m，以碎石土层作为桩端持力层，桩端进入持力层7m；地基中分布有厚度达17m的淤泥，其不排水抗剪强度为9kPa。主楼局部基础剖面及地质情况如图5-8所示，地下水位稳定于地面以下1m，λ为抗拔系数。 提示：按《建筑桩基技术规范》（JGJ 94—2008）作答。 主楼范围以外的地下室工程桩均按抗拔桩设计，一柱一桩，抗拔桩未采取后注浆措施。已知抗拔桩的桩径、桩顶标高及桩底端标高同图16（Z）所示的承压桩（容重为25kN\u002Fm3）。试问，为满足地下室抗浮要求，荷载效应标准组合时，基桩允许拔力最大值（kN）与下列何项数值最为接近？（ ） 提示：单桩抗拔极限承载力标准值可按土层条件计算。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","850",false,{"key":16,"text":17,"correct":18},"B","1000",true,{"key":20,"text":21,"correct":14},"C","1700",{"key":23,"text":24,"correct":14},"D","2000","",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]