[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929403":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},929403,600,1,"单选题","某群桩基础的平面，本桩基设计等级为乙级。剖面和地基土层分布情况如图所示。地质情况如下： ①杂填土：重度γ＝17.8kN\u002Fm3； ②淤泥质土：γ＝17.8kN\u002Fm3，桩的极限侧阻力标准值qsik＝20kPa，属高灵敏度软土； ③黏土：其重度γ＝19.5kN\u002Fm3，桩的极限侧阻力标准值qsik＝60kPa，土的压缩模量Es1＝8.0MPa； ④淤泥质土：地基承载力标准值fk＝70kPa，压缩模量Es2＝1.6MPa；在桩长深度范围内各土层的加权平均土层极限摩擦力标准值qsk＝21kPa。 且作用于桩基承台顶面的竖向力设计值F＝3600kN，桩基承台和承台上土自重设计值G＝480kN。 3.当Qsk＝440.59kN，Qpk＝301.24kN时，基桩的竖向承载力特征值（kN）与下列（ ）项值接近。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","370.92",true,{"key":16,"text":17,"correct":18},"B","465.64",false,{"key":20,"text":21,"correct":18},"C","473.59",{"key":23,"text":24,"correct":18},"D","480.16","根据《建筑桩基技术规范》（JGJ 94—2008）第5.2.5条规定，由于承台底面以下存在高灵敏软土，不考虑承台效应，即ηc＝0；则基桩的竖向承载力特征值为： 由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]