[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929319":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},929319,600,1,"单选题","某商业楼为五层框架结构，设一层地下室，基础拟采用承台下桩基，柱A截面尺寸为800mm×800mm，预制方桩边长为350mm，桩长为27m，承台厚度为800mm，有效高度h0取750mm，板厚为600mm，承台及柱的混凝土强度等级均为C30（ft=1.43N／mm2），抗浮设计水位+5.000，抗压设计水位+3.500。柱A下基础剖面及地质情况见图。[2013年真题] 提示：根据《建筑地基基础设计规范》（GB 50007—2011）作答，根据《建筑桩基技术规范》（JGJ 94—2008）作答。 3.假定，各层土的基桩抗拔系数λ均为0.7。试问，预制桩基桩抗拔极限承载力标准值（kN）与下列何项数值最为接近？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","500",false,{"key":16,"text":17,"correct":14},"B","600",{"key":19,"text":20,"correct":21},"C","1100",true,{"key":23,"text":24,"correct":14},"D","1200","根据《建筑桩基技术规范》（JGJ 94—2008）第5.4.6条规定，预制桩基桩抗拔极限承载力标准值公式为： 代入数据可得，极限承载力为： 由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]