[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929239":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},929239,600,1,"单选题","",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","188.7",true,{"key":16,"text":17,"correct":18},"B","209.7",false,{"key":20,"text":21,"correct":18},"C","214.2",{"key":23,"text":24,"correct":18},"D","227.9","根据《砌体结构设计规范》（GB 50003—2011）表3.2.1-1可知，抗压强度设计值f=1.5MPa。 当烧结多孔砖孔洞率大于30%，应乘以0.9，又知A=0.49×0.37=0.1813m2＜0.3m2， 根据第3.2.3条第1款规定，γa=A+0.7=0.881，故取f=1.5×0.9×0.881=1.189MPa。 根据第5.1.1～5.1.2条进行计算，高厚比β=H0\u002Fh=3.6\u002F0.37=9.73，查附录D表 D．0.1-1得，影响系数为：φ=0.875；则该柱承载力为：N=φfA=0.875×1.189×181300=188.6kN。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]