[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929237":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},929237,600,1,"单选题","关于木结构，下列哪一种说法是不正确的？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","现场制作的原木、方木承重构件，木材的含水率不应大于25％",false,{"key":16,"text":17,"correct":14},"B","普通木结构受弯或压弯构件当采用原木时，对髓心不做限制指标",{"key":19,"text":20,"correct":21},"C","木材顺纹抗压强度最高，斜纹承压强度最低，横纹承压强度介于两者之间",true,{"key":23,"text":24,"correct":14},"D","标注原木直径时，应以小头为准；验算原木构件挠度和稳定时，可取中央截面","A项，根据《木结构设计规范》（GB 50005—2003）（2005年版）第3.1.13条第1款规定，现场制作的原木或方木结构不应大于25%，正确；B项，根据第3.1.2条及表 A．1.3规定，受弯或压弯普通木结构构件的材质等级应选用IIa级，当采用材质等级选用Ⅱa级时，对髓心不做限制，正确；C项，根据图4.2.6可知，木材顺纹抗压强度最高，横纹抗压强度最低，斜纹抗压强度介于两者之间，不正确；D项，根据第4.2.10条规定，原木构件沿其长度的直径变化率，可按每米9mm（或当地经验数值）采用。验算挠度和稳定时，可取构件的中央截面，验算抗弯强度时，可取最大弯矩处的截面，正确。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]